We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR X G 1H 2001 c - Burners & Combustion
FBRBurners & Combustion

FBR X G 1H 2001 c

FBR X G 1H 2001 c is a single-stage light-oil diesel burner delivering 23.7–59.3 kW thermal power with a 112 mm nozzle. Operating at 57–59 dBA and IP 40 protection, it suits industrial heating and combustion…

SKU 3G-FBR-00011

Brand
FBR
Item
X G 1H 2001 c
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
10 kg
stage
Single stage
fuel type
Light oil
nozzle mm
112
fan motor w
100
preheater w
30-110
power kw max
59.3
power kw min
23.7
flow kg h max
5
flow kg h min
2
ip protection
IP 40
noisiness dba
57-59
electrical supply
1
power supply info
1N~230V
current absorption a
1
thermal power mcal h
20.4-51
nominal electric power w
220
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS ONE STAGE SK070044_A_en LIGHT-OIL BURNERS ONE STAGE G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1H - G 1S - G 2H MAXI - G 2S MAXI Light-oil burners single stage. They are composed by: aluminium frame, protection cover with noise reduction plate, combustion head with micro adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. In the versions H hydraulic device of closing air shutter. In the versions R preheater with control of temperature for soft and sicure ignitions also at low temperatures. Complete of connector 7 poles, flange and gasket for installation on boiler, nozzle, flexible pipes, line filter. Fig. 1 G 0S Fig. 2 G 1S Fig. 3 G 2S MAXI G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1H - G 1S - G 2H MAXI - G 2S MAXI LIGHT-OIL BURNERS ONE STAGE SK070044_A_en TECHNICAL DATA G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1H - G 1S - G 2H MAXI - G 2S MAXI MODEL G 0HR G 0H G 1HR G 1H G 2H G 0SR G 0S G 1S MAXI G 2S MAXI Flow min. - max. * [kg/h] 1.2-3.1 2.0-3.3 2.0-5.0 2.0-5.0 4-9.8 Thermal power min. - max. * [Mcal/h] 12.2-31.6 20.4-33.7 20.4-51 20.4-51 40.8-99.9 Thermal power min. - max. * [kW] 14.2-36.7 23.7-39.1 23.7-59.2 23.7-59.2 47.3-116 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) one stage Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [W] 190 120 220 130 140 Fan motor [W] 90 90 100 100 100 Nominal current absorption [A] 0.9 0.6 1 0.6 0.7 Pre-heater [W] 30-110 - 30-110 - - Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness min. - max. ** [db(A)] 56-58 56-58 57-59 57-59 59-61 Burner weight *** [kg] 9 9 10 10 10 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the combustion laboratory, with burner on operation on beta boiler to 1m of distance (UNI EN ISO 3746). *** For burner with cover in steel (F) please add 3 kg to the weight. OPERATING RANGE DIAGRAM G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1H - G 1S - G 2H MAXI - G 2S MAXI Fig. 2 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1H - G 1S - G 2H MAXI - G 2S MAXI LIGHT-OIL BURNERS ONE STAGE SK070044_A_en DIMENSIONS [MM] Fig. 3 Dimensions G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1H - G 1S - G 2H MAXI - G 2S MAXI MODEL A B C D E F G H I G0...2001 137 137 240 80 223 169 15 150 150 G1...2001 157 170 275 80 265 210 15 150 150 G2...MAXI 157 170 275 90 265 210 15 150 150 * See "flame tube length" BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 4 Boiler plate MODEL L min L* L max M N min N* N max G0...2001 mm 130 150 170 M8 90 110 130 G1...2001 mm 130 150 170 M8 90 110 130 G2...MAXI mm 130 150 170 M8 100 110 130 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** G0...2001 mm 112 152 G1...2001 mm 112 152 G2...MAXI mm 107 147 ** For different flame lengths, please contact our Technical-Sales Department. G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1H - G 1S - G 2H MAXI - G 2S MAXI LIGHT-OIL BURNERS ONE STAGE SK070044_A_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners one stage. DETAILED SPECIFICATION Light-oil burner one stage composed by: • Aluminium frame; • Combustion head with micro adjustment at high efficiency and high flame stability; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Photoresistance for flame detection; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1H - G 1S - G 2H MAXI - G 2S MAXI
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR X G 1H 2001 c is a single-stage light-oil diesel burner delivering 23.7–59.3 kW thermal power with a 112 mm nozzle. Operating at 57–59 dBA and IP 40 protection, it suits industrial heating and combustion applications requiring reliable, moderate-noise fuel-burning capacity.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR X G 1H 2001 c diesel burner in the Philippines?

3G Electric Philippines supplies the FBR X G 1H 2001 c burner with delivery to Manila and Quezon City. We handle all logistics, Bureau of Customs documentation, and PHP invoicing. Lead time on request—contact us for availability and quotation.

What is the thermal output and nozzle size of this burner?

The FBR X G 1H 2001 c delivers 23.7–59.3 kW thermal power with a 112 mm nozzle. Fuel flow ranges from 2–5 kg/h. It operates at 57–59 dBA with IP 40 protection, ideal for industrial heating systems.

What are the electrical requirements for the FBR X G 1H 2001 c?

The burner operates on 1N~230V single-phase power supply with 1 A current absorption. The fan motor draws 100 W, and the preheater operates at 30–110 W depending on application and ambient conditions.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
X G oH 2001 c
FBR
X G oH 2001 c
X X G 1HR 2001 R c
FBR
X X G 1HR 2001 R c
X G 0S 2001 S
FBR
X G 0S 2001 S
X G 1.22 2001 SI
FBR
X G 1.22 2001 SI
X G IS 2001 S
FBR
X G IS 2001 S
X G 1/C 2001 TXC
FBR
X G 1/C 2001 TXC

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL