The WILKINS Complete Repair Kit (SKU RK34-975XL3, MPN RK34-975XL3) is a repair kit for Zurn backflow preventers, compatible with the 975XL3 series and model 12-975XL3. It includes a Relief Valve Plunger-Upper and is…

SKU 3G-OTH-427840

Also listed as: RK34975XL3 · RK34 975XL3

Brand
WILKINS
Item
RK34-975XL3 Repair Kit for Zurn 975XL3 Backflow Preventers
Part Number
RK34-975XL3
Category
Repair Kits & Parts for Zurn Backflow Preventers
Available to Order
Also known as:RK34-975XL3WILKINS
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

WILKINS
Manufacturer Part Number
RK34-975XL3
Type
801H84/801H90, 12-975XL3/34-975XL3
Includes
Relief Valve Plunger-Upper
Compatible Valve Size
1/2 in
Compatible with Series
975XL3
Compatible with Mfr. Model No.
12-975XL3

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

WILKINS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The WILKINS Complete Repair Kit (SKU RK34-975XL3, MPN RK34-975XL3) is a repair kit for Zurn backflow preventers, compatible with the 975XL3 series and model 12-975XL3. It includes a Relief Valve Plunger-Upper and is designed for 1/2 in valve sizes.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the WILKINS RK34-975XL3 backflow preventer repair kit used for?

The WILKINS RK34-975XL3 is a complete repair kit for Zurn 975XL3 series backflow preventers. It is used to replace worn internal components, including the relief valve plunger-upper, to restore proper backflow protection in commercial and residential water systems. This kit is compatible with 1/2 in valve sizes and models 12-975XL3 and 34-975XL3.

What are the specifications of the WILKINS RK34-975XL3 repair kit?

The WILKINS RK34-975XL3 repair kit includes a relief valve plunger-upper and is compatible with 1/2 in valve sizes. It fits Zurn 975XL3 series backflow preventers and models 12-975XL3 and 34-975XL3. The manufacturer part number is RK34-975XL3, and it is also compatible with part number 12-975XL3.

Where to buy the WILKINS RK34-975XL3 repair kit worldwide?

You can source the WILKINS RK34-975XL3 repair kit through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time; we provide this kit as part of our extensive sourcing network for Zurn backflow preventer parts.

How to install the WILKINS RK34-975XL3 repair kit?

To install the WILKINS RK34-975XL3 repair kit, first depressurize and isolate the backflow preventer. Remove the valve bonnet and replace the old relief valve plunger-upper with the included component. Reassemble and test for proper operation. Always follow the manufacturer's instructions for your specific Zurn 975XL3 series model to ensure correct installation and backflow protection.

Used in

Common applications for WILKINS
Commercial water distribution — WILKINS 600XL series pressure reducing valves for regulating supply pressure in multi-story buildings.
Irrigation systems — WILKINS 975XL2 backflow preventers to protect potable water from contamination in agricultural setups.
Industrial process control — WILKINS 375ST reduced pressure principle backflow preventers for cross-connection control in manufacturing plants.
Municipal water treatment — WILKINS low-lead pressure regulators like the 1-600XL3DU for compliance with potable water standards.
HVAC systems — WILKINS 112-NR3XLDULU regulators for maintaining consistent water pressure in heating and cooling loops.
Fire protection systems — WILKINS backflow preventers for backflow prevention in sprinkler and standpipe systems.
Not sure this is the right part? Photo-identify it

WILKINS Products

3G Electric supplies WILKINS repair kits & parts for zurn backflow preventers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from WILKINS

View all WILKINS parts
WILKINS
WILKINS
This repair kit is designed for servicing Zurn backflow preventers with a 6-inch compatible valve size. It includes a No. 1 Check Assembly and is compatible with Series 350AST and Model 6-350AST. Typical applications include maintenance of backflow prevention in commercial and industrial water systems
This repair kit includes a union gasket and is designed for 3/4 in valve sizes. It is a universal tail piece kit suitable for servicing backflow preventers in plumbing systems
WILKINS
This repair kit includes a union gasket and is designed for 3/4 in valve sizes. It is a universal tail piece kit suitable for servicing backflow preventers in plumbing systems
WILKINS
WILKINS
Repair kit for Zurn Series 950 backflow preventers, compatible with valve sizes 1-1/4 in to 2 in. Includes a cover O-ring. Used for maintenance of backflow prevention assemblies in water supply systems