We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

WILKINS Reduced Pressure Zone Backflow Preventer: 375, Std Configuration, Glass-Filled Nylon - Zurn RPZ Backflow Preventers
WILKINSZurn RPZ Backflow Preventers

WILKINS Reduced Pressure Zone Backflow Preventer: 375, Std Configuration, Glass-Filled Nylon

The WILKINS Reduced Pressure Zone Backflow Preventer: 375 is a Zurn RPZ backflow preventer with a flange connection and ball valve shut-off. This model, manufacturer part number 1-375, features a standard…

SKU 3G-OTH-440416

Also listed as: 1375 · 1 375

Brand
WILKINS
Item
Reduced Pressure Zone Backflow Preventer: 375, Std Configuration, Glass-Filled Nylon
Category
Zurn RPZ Backflow Preventers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

WILKINS
Manufacturer Part Number
1-375
Type
Std Configuration, Glass-Filled Nylon, Flange
Connection Type
Flange
Shut-Off Valve Type
Ball Valve

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

WILKINS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The WILKINS Reduced Pressure Zone Backflow Preventer: 375 is a Zurn RPZ backflow preventer with a flange connection and ball valve shut-off. This model, manufacturer part number 1-375, features a standard configuration with a glass-filled nylon body.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the WILKINS 375 Reduced Pressure Zone Backflow Preventer used for?

The WILKINS 375 is a Zurn RPZ backflow preventer designed to protect potable water supplies from cross-connection contamination in commercial, industrial, and municipal applications. It prevents reverse flow of non-potable water into clean water lines, ensuring compliance with plumbing codes.

What are the specifications of the WILKINS 375 backflow preventer?

The WILKINS 375 (MPN 1-375) features a glass-filled nylon body, a flange connection type, and a ball valve shut-off. It is a standard-configuration Zurn RPZ backflow preventer suitable for high-hazard cross-connection protection. Always verify pressure and temperature ratings with the manufacturer.

Where to buy the WILKINS 375 backflow preventer worldwide?

3G Electric supplies the WILKINS 375 Reduced Pressure Zone Backflow Preventer worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact our team to source this Zurn RPZ model for your project.

How to install a WILKINS 375 RPZ backflow preventer?

Install the WILKINS 375 in an accessible, above-ground location with adequate drainage. Ensure the flange connections are properly aligned and gasketed. Install shut-off ball valves upstream and downstream. Follow local plumbing codes and the manufacturer's instructions for testing and commissioning.

Used in

Common applications for WILKINS
Commercial water distribution — WILKINS 600XL series pressure reducing valves for regulating supply pressure in multi-story buildings.
Irrigation systems — WILKINS 975XL2 backflow preventers to protect potable water from contamination in agricultural setups.
Industrial process control — WILKINS 375ST reduced pressure principle backflow preventers for cross-connection control in manufacturing plants.
Municipal water treatment — WILKINS low-lead pressure regulators like the 1-600XL3DU for compliance with potable water standards.
HVAC systems — WILKINS 112-NR3XLDULU regulators for maintaining consistent water pressure in heating and cooling loops.
Fire protection systems — WILKINS backflow preventers for backflow prevention in sprinkler and standpipe systems.

WILKINS Products

3G Electric supplies WILKINS zurn rpz backflow preventers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
WILKINS Reduced Pressure Zone Backflow Preventer: 375, Std Configuration, Glass-Filled Nylon, Flange (MPN 114-375)
WILKINS
WILKINS Reduced Pressure Zone Backflow Preventer: 375, Std Configuration, Glass-Filled Nylon, Flange (MPN 114-375)
WILKINS Reduced Pressure Zone Backflow Preventer: 375, Std Configuration, Glass-Filled Nylon, Flange (MPN 112-375)
WILKINS
WILKINS Reduced Pressure Zone Backflow Preventer: 375, Std Configuration, Glass-Filled Nylon, Flange (MPN 112-375)
WILKINS Reduced Pressure Zone Backflow Preventer: 375, Std Configuration, Glass-Filled Nylon, Flange (MPN 2-375)
WILKINS
WILKINS Reduced Pressure Zone Backflow Preventer: 375, Std Configuration, Glass-Filled Nylon, Flange (MPN 2-375)
WILKINS Reduced Pressure Zone Backflow Preventer: 375, Std Configuration, Glass-Filled Nylon, Flange (MPN 34-375)
WILKINS
WILKINS Reduced Pressure Zone Backflow Preventer: 375, Std Configuration, Glass-Filled Nylon, Flange (MPN 34-375)
WILKINS Reduced Pressure Zone Backflow Preventer: 375A, Std Configuration, Ductile Iron, Flange (MPN 3-375A)
WILKINS
WILKINS Reduced Pressure Zone Backflow Preventer: 375A, Std Configuration, Ductile Iron, Flange (MPN 3-375A)
WILKINS Reduced Pressure Zone Backflow Preventer: 375A, Std Configuration, Ductile Iron, Flange (MPN 212-375A)
WILKINS
WILKINS Reduced Pressure Zone Backflow Preventer: 375A, Std Configuration, Ductile Iron, Flange (MPN 212-375A)

More from WILKINS

View all WILKINS parts
WILKINS
WILKINS
WILKINS Reduced Pressure Principle Backflow Prev: 375AST, Std Configuration, 304L Stainless Steel (MPN 3-375AST)
WILKINS Reduced Pressure Zone Backflow Preventer: 975XL, Std Configuration, Bronze, 2 in Pipe Size (MPN 2-975XL)
WILKINS
WILKINS Reduced Pressure Zone Backflow Preventer: 975XL, Std Configuration, Bronze, 2 in Pipe Size (MPN 2-975XL)
WILKINS Backflow Preventer: 975XL2, With Strainer, Bronze, 3/4 in Pipe Size, FNPT, 33°F – 180°F (MPN 34-975XL2SAG)
WILKINS
WILKINS Backflow Preventer: 975XL2, With Strainer, Bronze, 3/4 in Pipe Size, FNPT, 33°F – 180°F (MPN 34-975XL2SAG)
WILKINS Pressure Principle Backflow Preventer 21: 375AST, Std Configuration, 304L Stainless Steel (MPN 212-375AST)
WILKINS
WILKINS Pressure Principle Backflow Preventer 21: 375AST, Std Configuration, 304L Stainless Steel (MPN 212-375AST)
WILKINS W/Ubv Non-Potable 1" 975Xl: 975XL2U, Std Configuration, Bronze, 1 in Pipe Size, 33°F – 180°F (MPN 1-975XLU)
WILKINS
WILKINS W/Ubv Non-Potable 1" 975Xl: 975XL2U, Std Configuration, Bronze, 1 in Pipe Size, 33°F – 180°F (MPN 1-975XLU)
WILKINS Backflow Preventer: 375XLB, With Strainer, Bronze, 2 in Pipe Size, FNPT, 33°F – 180°F (MPN 2-375XLS)
WILKINS
WILKINS Backflow Preventer: 375XLB, With Strainer, Bronze, 2 in Pipe Size, FNPT, 33°F – 180°F (MPN 2-375XLS)
WILKINS Backflow Preventer: 975XL3, Std Configuration, Bronze, 1 1/2 in Pipe Size, MNPT, Ball Valve (MPN 112-975XL3)
WILKINS
WILKINS Backflow Preventer: 975XL3, Std Configuration, Bronze, 1 1/2 in Pipe Size, MNPT, Ball Valve (MPN 112-975XL3)
WILKINS Pressure Principle Backflow Preventer: 375A, Std Configuration, Ductile Iron, 6 in Pipe Size (MPN 6-375A)
WILKINS
WILKINS Pressure Principle Backflow Preventer: 375A, Std Configuration, Ductile Iron, 6 in Pipe Size (MPN 6-375A)