We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

TACO Low Water Cutoff: Steam and Hot Water Boilers, 120V AC, SPDT, Manual Reset - Low-Water Cut-Off Controls
TACOLow-Water Cut-Off Controls

TACO Low Water Cutoff: Steam and Hot Water Boilers, 120V AC, SPDT, Manual Reset

The TACO Low Water Cutoff (SKU LFM1203S-1, MPN LFM1203S-1) is a low-water cut-off control for steam and hot water boilers. It features a manual reset, SPDT switch, NEMA 1 rating, and includes a test button. This unit…

SKU 3G-OTH-68326

Also listed as: LFM1203S1 · LFM1203S 1

Brand
TACO
Item
Low Water Cutoff: Steam and Hot Water Boilers, 120V AC, SPDT, Manual Reset
Category
Low-Water Cut-Off Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

TACO
Manufacturer Part Number
LFM1203S-1
Type
SPDT, Manual Reset, Foam Compensating
AC
120V
Reset Type
Manual
NEMA Rating
1
Switch Type
SPDT
Compensates for Foam
Yes
Test Button Included
Yes

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

TACO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The TACO Low Water Cutoff (SKU LFM1203S-1, MPN LFM1203S-1) is a low-water cut-off control for steam and hot water boilers. It features a manual reset, SPDT switch, NEMA 1 rating, and includes a test button. This unit compensates for foam and operates on 120V AC.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the TACO LFM1203S-1 low water cutoff used for?

The TACO LFM1203S-1 low water cutoff protects steam and hot water boilers from damage caused by low water conditions. It automatically shuts down the burner when water level drops, and its foam-compensating design prevents false trips in foamy boiler water.

What are the specifications of the TACO LFM1203S-1?

The TACO LFM1203S-1 operates on 120V AC, features a manual reset SPDT switch, NEMA 1 enclosure, and includes a test button. It compensates for foam, making it suitable for steam and hot water boiler applications. Manufacturer part number LFM1203S-1.

Where to buy the TACO LFM1203S-1 worldwide?

3G Electric supplies the TACO LFM1203S-1 low water cutoff to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for a quote and lead time on this manual reset, foam-compensating control.

How to install the TACO LFM1203S-1 low water cutoff?

Install the TACO LFM1203S-1 according to the manufacturer's instructions and local codes. Mount it in the boiler's water-level sensing location, wire the 120V AC SPDT switch to the burner circuit, and test operation using the built-in test button. Manual reset requires a physical button press after a low-water event.

Used in

Common applications for TACO
Hydronic heating systems — TACO 007 series circulator pumps for residential boiler water circulation.
Commercial HVAC — TACO 2400-60-3P inline pump for chilled water loops in large buildings.
Industrial process cooling — TACO 1630EAE10132096 pump for high-flow (110 gpm) cooling applications.
Zone control in radiant floor heating — TACO V075T2G2ZA024Q4A2 zone valve for regulating flow to individual zones.
Pump replacement and maintenance — TACO 007-045RP cartridge assembly for servicing existing 007 series pumps.
Piping connections in hydronic systems — TACO 110-251F-1 flange for joining pumps to pipework.

TACO Products

3G Electric supplies TACO low-water cut-off controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
HAYWARD FLOW CONTROL Electrically Actuated Two-Way Ball Valve: 2 in, CPVC, 24 to 265V AC/DC (MPN ECPTBH220STE)
HAYWARD FLOW CONTROL
HAYWARD FLOW CONTROL Electrically Actuated Two-Way Ball Valve: 2 in, CPVC, 24 to 265V AC/DC (MPN ECPTBH220STE)
HAYWARD FLOW CONTROL Electrically Actuated Two-Way Ball Valve: 2 in, PVC, 24 to 265V AC/DC, Straight (MPN ECPTBH120STV)
HAYWARD FLOW CONTROL
HAYWARD FLOW CONTROL Electrically Actuated Two-Way Ball Valve: 2 in, PVC, 24 to 265V AC/DC, Straight (MPN ECPTBH120STV)
This 1-inch CPVC electrically-actuated ball valve provides automated on/off flow control. The actuator includes thermal overload protection and operates on 24 to 265V AC/DC power. Suitable for corrosive fluid handling in industrial piping systems
HAYWARD FLOW CONTROL
This 1-inch CPVC electrically-actuated ball valve provides automated on/off flow control. The actuator includes thermal overload protection and operates on 24 to 265V AC/DC power. Suitable for corrosive fluid handling in industrial piping systems
This CPVC electrically-actuated ball valve is designed for automated on/off flow control in corrosive fluid handling systems. The valve body is constructed from CPVC, and the actuator includes a heater for reliable operation across a wide voltage range of 24 to 265V AC/DC. Suitable for applications such as chemical processing and water treatment where corrosion resistance and remote actuation are required
HAYWARD FLOW CONTROL
This CPVC electrically-actuated ball valve is designed for automated on/off flow control in corrosive fluid handling systems. The valve body is constructed from CPVC, and the actuator includes a heater for reliable operation across a wide voltage range of 24 to 265V AC/DC. Suitable for applications such as chemical processing and water treatment where corrosion resistance and remote actuation are required
HAYWARD FLOW CONTROL Electrically Actuated Two-Way Ball Valve: 1 1/2 in, CPVC, 24 to 265V AC/DC (MPN ECPTBH215STV)
HAYWARD FLOW CONTROL
HAYWARD FLOW CONTROL Electrically Actuated Two-Way Ball Valve: 1 1/2 in, CPVC, 24 to 265V AC/DC (MPN ECPTBH215STV)
HAYWARD FLOW CONTROL Electrically Actuated Two-Way Ball Valve: 1/2 in, CPVC, 24 to 265V AC/DC (MPN ECPTBH205STE)
HAYWARD FLOW CONTROL
HAYWARD FLOW CONTROL Electrically Actuated Two-Way Ball Valve: 1/2 in, CPVC, 24 to 265V AC/DC (MPN ECPTBH205STE)

More from TACO

View all TACO parts
Low-water cut-off control for steam and hot water boilers. Features automatic reset, SPDT switch, NEMA 1 enclosure, test button, and foam compensation. Operates on 120V AC
TACO
Low-water cut-off control for steam and hot water boilers. Features automatic reset, SPDT switch, NEMA 1 enclosure, test button, and foam compensation. Operates on 120V AC
Low-water cut-off control for residential boilers, automatically shuts off burner when water level drops to prevent dry-fire damage. Features SPDT switch, automatic reset, NEMA 1 enclosure, and test button. Operates on 24V AC and does not compensate for foam
TACO
Low-water cut-off control for residential boilers, automatically shuts off burner when water level drops to prevent dry-fire damage. Features SPDT switch, automatic reset, NEMA 1 enclosure, and test button. Operates on 24V AC and does not compensate for foam
This low-water cut-off control protects hot water boilers by shutting down the burner when water level drops. It features SPDT switch, automatic reset, and a test button. Operates on 24V AC with NEMA 1 rating. Does not compensate for foam
TACO
This low-water cut-off control protects hot water boilers by shutting down the burner when water level drops. It features SPDT switch, automatic reset, and a test button. Operates on 24V AC with NEMA 1 rating. Does not compensate for foam
Low Water Cutoff: Steam and Hot Water Boilers, 24V AC, SPDT, Auto Reset, Foam Compensating (MPN LFA0243S-1)
TACO
Low Water Cutoff: Steam and Hot Water Boilers, 24V AC, SPDT, Auto Reset, Foam Compensating (MPN LFA0243S-1)
Low Water Cutoff: Steam and Hot Water Boilers, 24V AC, SPDT, Manual Reset, Foam Compensating (MPN LFM0243S-1)
TACO
Low Water Cutoff: Steam and Hot Water Boilers, 24V AC, SPDT, Manual Reset, Foam Compensating (MPN LFM0243S-1)