We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Suntec M2C/M3C - Gas valve
SuntecGas valve

Suntec M2C/M3C

The SUNTEC multifunctional gas valves M2C and M3C are design to be adapted on every type of 1-stage gas burner. Made up of 2 class A+A solenoid valves and a high accuracy gas regulator, they allied safety and…

SKU 3G-OTH-02673

Also listed as: M2CM3C · M2C M3C

Brand
Suntec
Item
M2C/M3C
Category
Gas valve
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Suntec
Compatible fuels
LPG, Natural gas, H2 Blend

Datasheet Content

[{"filename":"M2C_EN_sept_2024.pdf","text":"MULTIFUNCTIONAL GAS\n\n VALVE M2C M2C\n M2C - 11 - Ed 7 - September 2024\nThis is a general documentation; for specific applications not covered by this leaflet, MULTIFUNCTIONAL GAS VALVE\nplease consult us. IDENTIFICATION\nThe SUNTEC M2C multifunctional gas valve is a 1-stage system.\n (Not all model combinations are available. Consult\nThis multifunctional gas valve consists of 2 safety valves and constant pressure regulator your Suntec representative)\ncontrolled by a servo-regulator.\n Gas valve size\n\n\nAPPLICATIONS Pressure regulator type\n C = Constant pressure regulator\n\nThe SUNTEC multifunctional gas valve is recommended for collective or industrial pressure\n Maximum inlet pressure / Valve class\njet burners.\n 5 = 360 mbar - A+A\nThe use of the SUNTEC multifunctional gas valve is recommended in all gas installations\nrequiring a safety shutoff and pressure control, for inlet pressure up to 360 mbar. Regulator pressure range\n 2 = 4 - 20 mbar\nIt is suitable for use with 1st, 2nd and 3rd family gases (according to EN 437). 5 = 4 - 50 mbar\n\n\n 2nd safety valve opening\nOPERATION PRINCIPLE F = Fast opening\n S = Slow opening\n\nSafety valve Safety valves type of supply\nM2C multifunctional gas valve comprises two class A automatic safety valves, direct-acting, 0 = Independent\nelectrically operated. 1 = Simultaneous\nAt rest, both safety valves are closed; thus gas cannot flow beyond chamber ①.\nWhen energized, the coils open and release the gas flow from chamber ① to chamber ② Coils voltage\n 7 = 230 V AC\nfor safety valve V1 (from chamber ③ to chamber ④ for V2).\nWhen de-energized, each safety valve closes within 0.2 s.\n\nPressure regulator\n M2 C 5 2 S 1 7 - 2 - 1 0 8 6\nThe gas pressure regulator is normally closed type, pneumatically operated by a servo system.\nThe servo system controls the main regulator valve opening to equilibrate – through a\ndiaphragm – the downstream pressure (in chamber ③) to a setpoint adjusted by the screw S. Revision\n\nIn relation to this given set point, if the gas pressure in the chamber ③ is :\n Customization code\n • Lower, the servo-regulator opens and sends pressure into the chamber ⑤ to lift the\n main diaphragm. The pressure regulator then opens.\n Hydraulic\n → The regulated pressure (in chamber ③) increases. damper\n\n • Upper, the servo-regulator closes and sends less pressure into the chamber ⑤ to\n lower the main diaphragm. The regulator closes partially.\n → The regulated pressure (in chamber ③) decreases.\n • Equal to the set pressure, the servo-regulator maintains its opening to maintain the\n pressure in the chamber ⑤.\n → The regulated pressure (in chamber ③) remains stable. V1 V2\nThis design allows for excellent precision when regulating the downstream pressure,\nregardless to upstream pressure variation or downstream flow changes.\n ①\n ②\nSlow opening (M2C**S) ④\nA hydraulic damper, placed above the safety valve V2, offers the possibility to dampen the ③\nmovement of the safety valve V2 and thus apply a progressive gas flow in the combustion\nchamber in the starting phases. ⑤\n S\nThis device allows a slow initial opening (ignition flow) of the safety valve V2, adjustable\nup to 80% of the maximum flow.\n\n\n\n Sectional drawing of multifunctional gas valve M2C**S\n\n SUNTEC INDUSTRIES FRANCE - 1, rue Lavoisier - CS 60 102 - F-21603 LONGVIC Cedex - www.suntec.fr\n\f TECHNICAL SPECIFICATIONS FLOW CURVES\n\nGeneral\nMaximum operating 360 mbar\npressure\nAmbient temperature -20°C to +60°C\nrange\nOperation with Air and gas of 1st, 2nd and 3rd families\nBody Aluminium\nWeight • M2C**F : 2.3 kg\n • M2C**S : 2.5 kg\nCertification CE: Certificate n°1312CU6361\n UKCA : certificate n°8510/0099\nInlet/outlet flanges • DN15 (Rp1/2'')\n • DN20 (Rp3/4'')\nPressure taps G1/8\" connections\n Supplied in 3 locations on the multifunctional gas\n valve, and on inlet/outlet flanges.\nInlet strainer Mesh size : 0.6 mm.\n Replaceable filter.\nPressure switch Factory mounted on inlet flange.\n(optional) When suitable configuration, can be side-mounted.\n P burner = 3 mbar\n Flange = Rp3/4''\nSafety valve characteritics\nLeakage class Class A+A Maximum flow can be reduced when other\nOpening time (EN 161) • M2C**F : < 0.5 s flanges are connected with.\n • M2C**S : < 10 s (For other setting, contact SUNTEC.)\nClosing time (EN 161) • M2C**F : < 0.2 s\n • M2C**S : < 0.2 s\nVoltage 230 V AC, 50/60 Hz\nConsumption 34 VA\nIP rating IP54 (with suitable connector) according to\n EN 60529 standard.\n\nPressure regulator\nPressure regulator Class B according to EN 88-1, placed between\n the safety valves V1 and V2.\nRegulated pressure range • 4-20 mbar (M2C52**7)\n • 4-50 mbar (M2C55**7)\nDelivery pressure 10 mbar\n\n\n\n\n DIMENSIONS (in mm)\n\n\n\n\n 182 (M*C**S - slow opening)\n\n\n 133 (M*C**F - fast opening)\n\n\n\n 44\n\n\n\n 110 40\n 165 112\n 188\n\n\n\n\nWe reserve the right to change specifications without prior notice. M2C - 11 - Ed 7 - Sept 2024"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Suntec Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SUNTEC multifunctional gas valves M2C and M3C are design to be adapted on every type of 1-stage gas burner. Made up of 2 class A+A solenoid valves and a high accuracy gas regulator, they allied safety and reliability in every configuration.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Suntec M2C/M3C gas valve used for?

The Suntec M2C/M3C multifunctional gas valve is designed for 1-stage gas burners in collective or industrial pressure jet burner applications. It provides safety shutoff and pressure control for LPG, natural gas, and H2 blend fuels, with inlet pressure up to 360 mbar.

What are the specifications of the Suntec M2C/M3C gas valve?

The Suntec M2C/M3C gas valve features two class A+A solenoid valves and a constant pressure regulator. It supports LPG, natural gas, and H2 blend fuels, with a maximum inlet pressure of 360 mbar and regulator pressure ranges of 4-20 mbar or 4-50 mbar. Coil voltage options include 230 V AC.

Where to buy the Suntec M2C/M3C gas valve in Singapore?

You can source the Suntec M2C/M3C gas valve through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for availability and lead time on this Suntec multifunctional gas valve.

How to install the Suntec M2C/M3C gas valve?

Installation of the Suntec M2C/M3C gas valve should follow the manufacturer's guidelines. Ensure the valve is correctly sized for your burner and fuel type. The two safety valves close within 0.2 seconds when de-energized. Always consult a qualified technician for proper setup and compliance with local gas regulations.

Used in

Common applications for Suntec
Oil-fired heating systems — Suntec AUV 47L and AUV 47R pumps supplying fuel to burner nozzles at controlled pressure
Industrial burner fuel delivery — Replacement AFG and AS47 fuel pumps for scheduled maintenance and emergency system restoration
Legacy burner commissioning — Suntec E6NA and compatible pump variants integrated into retrofit or existing heating installations
Heating plant maintenance — Suntec coupling assemblies and coil spares enabling field repair of motor-pump drive units without full unit replacement
Equipment retrofit and modernization — Suntec spare parts and pump variants supporting equipment upgrades while maintaining original burner compatibility

Suntec Products

3G Electric supplies Suntec gas valve. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Solenoid valve 3/2 1/8" NF 230V brass
CBM
Solenoid valve 3/2 1/8" NF 230V brass
Corner valve 12X17 E-S gas F TG30001
CBM
Corner valve 12X17 E-S gas F TG30001
Solenoid valve VMR 3 threaded D1" 500 Mbar
Elektrogas
Solenoid valve VMR 3 threaded D1" 500 Mbar
MI-T-M
MI-T-M
1-inch AGA-certified gas valve for controlling gas flow in industrial heating equipment such as pressure washers, boilers, and furnaces. Compatible with manufacturer model GH-2004-1230 and parts 1TDJ7/1TDJ8
Gas valve 3/4" Spring return
CBM
Gas valve 3/4" Spring return
Elektrogas
Elektrogas
Solenoid valve VMR 2 threaded D3/4" 500 Mbar

More from Suntec

View all Suntec parts
Suntec M2N/M3N
Suntec
Suntec M2N/M3N