We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

3G Electric
SQUARE D 8536SBG1V03 Enclosed Non-Reversing Starter with Thermal Overloads - Enclosed Non-Reversing Starters with Thermal Overloads
SQUARE DEnclosed Non-Reversing Starters with Thermal Overloads

SQUARE D 8536SBG1V03 Enclosed Non-Reversing Starter with Thermal Overloads

The SQUARE D Magnetic Motor Starter is an enclosed non-reversing starter with thermal overloads, NEMA Size 0, 2 poles, 18 A, and a 220/240V AC coil (MPN 8536SBG1V03). It is a single-phase unit with screw clamp…

SKU 3G-OTH-40469

Brand
SQUARE D
Item
8536SBG1V03 Enclosed Non-Reversing Starter with Thermal Overloads
Part Number
8536SBG1V03
Category
Enclosed Non-Reversing Starters with Thermal Overloads
Available to Order
Also known as:8536SBG1V03SQUARE D
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

SQUARE D
Manufacturer Part Number
8536SBG1V03
Type
NEMA Size 0, 18 A
Phase
Single
Poles
2
AC Coil
240V
Operator
None
Coil Voltage
220/240V AC
Operator Controls
None
Includes Pilot Light
No
Thermal Units Required
1 Melting Alloy Unit (Not Included)
Terminal Connection Type
Screw Clamp Terminals
Auxiliary Contacts Included
No Auxiliary Contacts Included

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SQUARE D Magnetic Motor Starter is an enclosed non-reversing starter with thermal overloads, NEMA Size 0, 2 poles, 18 A, and a 220/240V AC coil (MPN 8536SBG1V03). It is a single-phase unit with screw clamp terminals, no operator controls, no pilot light, and no auxiliary contacts. One melting alloy thermal unit (not included) is required for overload protection.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the SQUARE D 8536SBG1V03 magnetic motor starter used for?

The SQUARE D 8536SBG1V03 is an enclosed non-reversing magnetic motor starter used to start and stop single-phase motors in industrial applications such as conveyors, pumps, and fans. It provides overload protection via a melting alloy thermal unit (not included) and is rated for 18 A at 240V AC.

What are the specifications of the SQUARE D 8536SBG1V03 starter?

The SQUARE D 8536SBG1V03 is a NEMA Size 0, non-reversing, 2-pole starter with a 220/240V AC coil. It has screw clamp terminals, no operator controls, no pilot light, and no auxiliary contacts. It requires one melting alloy thermal unit (not included) for overload protection and is rated for 18 A single-phase operation.

Where to buy the SQUARE D 8536SBG1V03 starter worldwide?

You can source the SQUARE D 8536SBG1V03 magnetic motor starter through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide locations. Contact us for availability and lead time.

How to select the correct thermal unit for the SQUARE D 8536SBG1V03 starter?

To select the correct melting alloy thermal unit for the SQUARE D 8536SBG1V03 starter, match the unit's trip rating to the full-load current of your motor. Refer to the SQUARE D thermal unit selection chart for the appropriate part number. The starter requires one thermal unit (not included) for overload protection.

Used in

Common applications for SQUARE D
Commercial building electrical panels — Square D QO series plug-in circuit breakers for branch circuit protection
Industrial motor control centers — Square D QOB series bolt-on breakers in NQOD panelboards
Heating equipment installations — Square D QOU series unit-mount breakers for overcurrent protection
Outdoor electrical distribution — Square D L-Frame enclosures housing LAL/LHL breakers for 400 A service
Indoor facility power distribution — Square D Q-Frame enclosures with QBL/QDL breakers for 225 A circuits
Retrofit and replacement in existing Square D load centers — QO series breakers for 120/240V AC systems
Not sure this is the right part? Photo-identify it

SQUARE D Products

3G Electric supplies SQUARE D enclosed non-reversing starters with thermal overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from SQUARE D

View all SQUARE D parts

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first