We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

SQUARE D Load Center: 30 A Amps, 120/240V AC, 2 Spaces, 10kA, 0 Max. No. of Tandem Breakers - Square D QO - Main Lug Load Centers
SQUARE DSquare D QO - Main Lug Load Centers

SQUARE D Load Center: 30 A Amps, 120/240V AC, 2 Spaces, 10kA, 0 Max. No. of Tandem Breakers

The Square D QO2L30S is a 30 A main lug load center designed for indoor use, rated at 120/240V AC with a 10kA short circuit current rating. It features 2 spaces, 1-phase configuration, and a surface cover enclosure…

SKU 3G-OTH-609593

Brand
SQUARE D
Item
Load Center: 30 A Amps, 120/240V AC, 2 Spaces, 10kA, 0 Max. No. of Tandem Breakers
Category
Square D QO - Main Lug Load Centers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

SQUARE D
Manufacturer Part Number
QO2L30S
Type
10kA, Surface Cover
AC
120/240V
Phase
1
Spaces
2
Voltage
120/240V AC
Location
Indoor
Included Enclosure Cover
Surface Cover
Max. No. Of Tandem Breakers
0
Short Circuit Current Rating
10kA
Main Circuit Breaker or Main Lug
Main Lug
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Square D QO2L30S is a 30 A main lug load center designed for indoor use, rated at 120/240V AC with a 10kA short circuit current rating. It features 2 spaces, 1-phase configuration, and a surface cover enclosure, supporting 0 tandem breakers.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Square D QO2L30S load center used for?

The Square D QO2L30S is a 30 A main lug load center for indoor residential or light commercial branch circuits. It distributes power from a separate main breaker, supporting 120/240V AC, 1-phase, 2-space configurations with a surface cover enclosure.

What are the specifications of the Square D QO2L30S?

The Square D QO2L30S is rated 30 A, 120/240V AC, 10kA short circuit current, 1-phase, 2 spaces, 0 max tandem breakers. It includes a surface cover, is indoor-rated, and configured as a main lug type. 3G Electric supplies this genuine Square D part worldwide.

Where to buy the Square D QO2L30S load center worldwide?

3G Electric supplies the Square D QO2L30S load center to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for a quote and lead time on this genuine Square D part.

How to install the Square D QO2L30S load center?

Install the Square D QO2L30S indoors on a flat surface using the included surface cover. Connect line conductors to the main lugs and branch circuits to the QO breakers. Follow local electrical codes and the manufacturer's wiring diagram for safe 120/240V AC operation.

Used in

Common applications for SQUARE D
Commercial building electrical panels — Square D QO series plug-in circuit breakers for branch circuit protection
Industrial motor control centers — Square D QOB series bolt-on breakers in NQOD panelboards
Heating equipment installations — Square D QOU series unit-mount breakers for overcurrent protection
Outdoor electrical distribution — Square D L-Frame enclosures housing LAL/LHL breakers for 400 A service
Indoor facility power distribution — Square D Q-Frame enclosures with QBL/QDL breakers for 225 A circuits
Retrofit and replacement in existing Square D load centers — QO series breakers for 120/240V AC systems

SQUARE D Products

3G Electric supplies SQUARE D square d qo - main lug load centers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from SQUARE D

View all SQUARE D parts
Load Center: 100 A Amps, 120/240V AC, 6 Spaces, 10kA, 6 Max. No. of Tandem Breakers, Flush Cover (MPN QO612L100DF). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Flush Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 100 A Amps, 120/240V AC, 6 Spaces, 10kA, 6 Max. No. of Tandem Breakers, Flush Cover (MPN QO612L100DF). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Flush Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
Load Center: 100 A Amps, 120/240V AC, 8 Spaces, 10kA, 8 Max. No. of Tandem Breakers, Surface Cover (MPN QO816L100DS). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 100 A Amps, 120/240V AC, 8 Spaces, 10kA, 8 Max. No. of Tandem Breakers, Surface Cover (MPN QO816L100DS). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
Load Center: 125 A Amps, 208Y/120/240V AC, 24 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO324L125G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 125 A Amps, 208Y/120/240V AC, 24 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO324L125G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
Load Center: 125 A Amps, 208Y/120/240V AC, 20 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO320L125G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 125 A Amps, 208Y/120/240V AC, 20 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO320L125G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
Load Center: 225 A Amps, 208Y/120/240V AC, 42 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Outdoor (MPN QO342L225GRB). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Surface Cover; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
SQUARE D
Load Center: 225 A Amps, 208Y/120/240V AC, 42 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Outdoor (MPN QO342L225GRB). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Surface Cover; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
Load Center: 40 A Amps, 120/240V AC, 2 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Surface Cover (MPN QO2L40RB). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
SQUARE D
Load Center: 40 A Amps, 120/240V AC, 2 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Surface Cover (MPN QO2L40RB). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
Load Center: 100 A Amps, 120/240V AC, 6 Spaces, 10kA, 6 Max. No. of Tandem Breakers, Surface Cover (MPN QO612L100RB). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
SQUARE D
Load Center: 100 A Amps, 120/240V AC, 6 Spaces, 10kA, 6 Max. No. of Tandem Breakers, Surface Cover (MPN QO612L100RB). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
Load Center: 200 A Amps, 208Y/120/240V AC, 30 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO330L200G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 200 A Amps, 208Y/120/240V AC, 30 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO330L200G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.