We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

SJE-RHOMBUS Simplex Multi-Purpose Pump Control Panel - Multi-Purpose Pump Control Panels
SJE-RHOMBUSMulti-Purpose Pump Control Panels

SJE-RHOMBUS Simplex Multi-Purpose Pump Control Panel

The SJE-RHOMBUS Control Panel: Simplex is a multi-purpose pump control panel rated for 120/208/240V AC and 7 to 15 A. It features a visual alert output, a timed dose dosing schedule, and is non-reversing. This panel…

SKU 3G-OTH-103326

Brand
SJE-RHOMBUS
Item
Simplex Multi-Purpose Pump Control Panel
Category
Multi-Purpose Pump Control Panels
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

SJE-RHOMBUS
Manufacturer Part Number
EZS11W114H1J3A6A8AC10EP15A17G
Type
Single Phase, 7 to 15 A
AC
120/208/240V
Current
7 to 15 A
Alert Output
Visual
Rated Voltage
120/208/240V AC
Dosing Schedule
Timed Dose
Intrinsic Safety
Not Specified Intrinsically Safe
Switches Included
3
Includes Reversing
Non-Reversing

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SJE-RHOMBUS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SJE-RHOMBUS Control Panel: Simplex is a multi-purpose pump control panel rated for 120/208/240V AC and 7 to 15 A. It features a visual alert output, a timed dose dosing schedule, and is non-reversing. This panel includes three switches and is not specified as intrinsically safe.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the SJE-RHOMBUS simplex control panel used for?

The SJE-RHOMBUS simplex control panel is a multi-purpose pump control panel used in industrial and commercial applications for managing single-phase pumps. It provides timed dose dosing, visual alerts, and non-reversing operation, making it suitable for wastewater, effluent, and dewatering systems where reliable pump control is required.

What are the specifications of the SJE-RHOMBUS simplex control panel?

The SJE-RHOMBUS simplex control panel operates at 120/208/240V AC, single phase, with a current range of 7 to 15 A. It includes three switches, a visual alert output, and a timed dose dosing schedule. The panel is non-reversing and not specified as intrinsically safe. The manufacturer part number is EZS11W114H1J3A6A8AC10EP15A17G.

Where to buy the SJE-RHOMBUS simplex control panel worldwide?

You can source the SJE-RHOMBUS simplex control panel worldwide through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead times; we supply genuine SJE-RHOMBUS components for your pump control needs.

How to install the SJE-RHOMBUS simplex control panel?

Install the SJE-RHOMBUS simplex control panel by mounting it in a dry, accessible location and connecting the single-phase power supply (120/208/240V AC) per the wiring diagram. Ensure the pump load does not exceed 15 A. Follow standard electrical safety practices and local codes. For specific wiring details, refer to the manufacturer's manual.

Used in

Common applications for SJE-RHOMBUS
Municipal wastewater lift stations — SJE-RHOMBUS simplex grinder pump panels (e.g., NEX Grinder 1 ph, Simplex - 67C) for single-pump sewage systems
Commercial building sump pump control — SJE-RHOMBUS multi-purpose control panels (e.g., EZS11W914X3A6A8AC10E15A) for 120V AC sump pumps with visual alerts
Industrial effluent treatment — SJE-RHOMBUS duplex grinder panels (e.g., VSGD-240-3-16.5) for alternating pump operation in 208-240V AC three-phase systems
Residential septic systems — SJE-RHOMBUS float bracket assemblies (e.g., 4 Float Bracket with Mounting Device) for mounting level switches in septic tanks
Chemical dosing stations — SJE-RHOMBUS timed dose panels (e.g., EZP11W6C0H10E17A) for controlled discharge of chemicals at 120V AC
Outdoor pump stations — SJE-RHOMBUS outdoor-rated panels (e.g., EZP11W6C0H1JV8G10EP17A) with NEMA 3R enclosures for weather-exposed installations

SJE-RHOMBUS Products

3G Electric supplies SJE-RHOMBUS multi-purpose pump control panels. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Multi-purpose pump control panel for single-phase, non-reversing applications. Rated 120/208/240V AC, 7 to 15 A, with visual alert output. Includes 5 switches and timed dose dosing schedule. Suitable for managing a single pump in water and wastewater systems
SJE-RHOMBUS
Multi-purpose pump control panel for single-phase, non-reversing applications. Rated 120/208/240V AC, 7 to 15 A, with visual alert output. Includes 5 switches and timed dose dosing schedule. Suitable for managing a single pump in water and wastewater systems
This simplex pump control panel operates on single-phase 120/208/240V AC and handles 7 to 15 A. It includes two switches, provides a visual alert output, and uses a demand dose dosing schedule. The panel is non-reversing and is not specified as intrinsically safe, suitable for general pump control in water and wastewater systems
SJE-RHOMBUS
This simplex pump control panel operates on single-phase 120/208/240V AC and handles 7 to 15 A. It includes two switches, provides a visual alert output, and uses a demand dose dosing schedule. The panel is non-reversing and is not specified as intrinsically safe, suitable for general pump control in water and wastewater systems
SJE-RHOMBUS Control Panel: Simplex, Single Phase, 120/208/240V AC, 7 to 15 A, 3 Switches Included (MPN EZS11W114H3A6A8AC10E15A17J18A)
SJE-RHOMBUS
SJE-RHOMBUS Control Panel: Simplex, Single Phase, 120/208/240V AC, 7 to 15 A, 3 Switches Included (MPN EZS11W114H3A6A8AC10E15A17J18A)
This multi-purpose pump control panel is designed for single-phase pump applications requiring timed dose dosing and audio alert output. It operates at 120/208/240V AC with a current range of 7 to 15 A and includes four switches. The panel is non-reversing and is suitable for use in wastewater, effluent, and dewatering systems
SJE-RHOMBUS
This multi-purpose pump control panel is designed for single-phase pump applications requiring timed dose dosing and audio alert output. It operates at 120/208/240V AC with a current range of 7 to 15 A and includes four switches. The panel is non-reversing and is suitable for use in wastewater, effluent, and dewatering systems
This single-phase pump control panel operates at 120/208/240V AC with a current range of 7 to 15 A. It provides a visual alert output and uses a demand dose dosing schedule. The panel is non-reversing and is not specified as intrinsically safe. Suitable for automating and monitoring single-phase pump systems in wastewater, effluent, and dewatering applications
SJE-RHOMBUS
This single-phase pump control panel operates at 120/208/240V AC with a current range of 7 to 15 A. It provides a visual alert output and uses a demand dose dosing schedule. The panel is non-reversing and is not specified as intrinsically safe. Suitable for automating and monitoring single-phase pump systems in wastewater, effluent, and dewatering applications
Multi-purpose pump control panel for single-phase applications. Operates at 120/208/240V AC with a current range of 7 to 15 A. Features a timed dose dosing schedule and visual alert output. Non-reversing and not specified as intrinsically safe. Suitable for managing pump operation in wastewater, effluent, or dewatering systems
SJE-RHOMBUS
Multi-purpose pump control panel for single-phase applications. Operates at 120/208/240V AC with a current range of 7 to 15 A. Features a timed dose dosing schedule and visual alert output. Non-reversing and not specified as intrinsically safe. Suitable for managing pump operation in wastewater, effluent, or dewatering systems

More from SJE-RHOMBUS

View all SJE-RHOMBUS parts
This simplex pump control panel is designed for single-phase pump operation in wastewater, effluent, and dewatering applications. It operates at 120/208/240V AC with a current range of 7 to 15 A, features a timed dose dosing schedule, and includes an audio alert output for alarm conditions. The panel is non-reversing, not specified as intrinsically safe, and comes with four switches
SJE-RHOMBUS
This simplex pump control panel is designed for single-phase pump operation in wastewater, effluent, and dewatering applications. It operates at 120/208/240V AC with a current range of 7 to 15 A, features a timed dose dosing schedule, and includes an audio alert output for alarm conditions. The panel is non-reversing, not specified as intrinsically safe, and comes with four switches
SJE-RHOMBUS Control Panel: Duplex, Single Phase, 120/208/240V AC, 7 to 15 A, 3 Switches Included, 4X (MPN EZS41W114H3A6A8AC10E15A17G)
SJE-RHOMBUS
SJE-RHOMBUS Control Panel: Duplex, Single Phase, 120/208/240V AC, 7 to 15 A, 3 Switches Included, 4X (MPN EZS41W114H3A6A8AC10E15A17G)
This SJE-RHOMBUS duplex pump control panel is designed for multi-purpose pump control in industrial wastewater, sewage, and effluent systems. It operates on single-phase 120/208/240V AC, handles 9 to 20 A, and features a demand dose dosing schedule with an audio alert output. The NEMA 4X enclosure provides protection in wet or corrosive environments, and the panel is non-reversing
SJE-RHOMBUS
This SJE-RHOMBUS duplex pump control panel is designed for multi-purpose pump control in industrial wastewater, sewage, and effluent systems. It operates on single-phase 120/208/240V AC, handles 9 to 20 A, and features a demand dose dosing schedule with an audio alert output. The NEMA 4X enclosure provides protection in wet or corrosive environments, and the panel is non-reversing
Single-phase pump control panel for 120V AC applications with 7 to 15 A current range. Features timed dose dosing, visual alert output, and non-reversing operation. Includes three switches. Suitable for wastewater, sump, and effluent pump control in residential and light commercial systems
SJE-RHOMBUS
Single-phase pump control panel for 120V AC applications with 7 to 15 A current range. Features timed dose dosing, visual alert output, and non-reversing operation. Includes three switches. Suitable for wastewater, sump, and effluent pump control in residential and light commercial systems
SJE-RHOMBUS Control Panel: Simplex, Single Phase, 120V AC, 7 to 15 A, 3 Switches Included, 4X, EZ (MPN EZS21W914H3A6A8AC10E15A17G)
SJE-RHOMBUS
SJE-RHOMBUS Control Panel: Simplex, Single Phase, 120V AC, 7 to 15 A, 3 Switches Included, 4X, EZ (MPN EZS21W914H3A6A8AC10E15A17G)
SJE-RHOMBUS Control Panel: Duplex, Single Phase, 120/208/240V AC, 7 to 15 A, Sensor, Thermoplastic (MPN IFN41W114C6A8AC10E24F)
SJE-RHOMBUS
SJE-RHOMBUS Control Panel: Duplex, Single Phase, 120/208/240V AC, 7 to 15 A, Sensor, Thermoplastic (MPN IFN41W114C6A8AC10E24F)
SJE-RHOMBUS Control Panel: Simplex, Single Phase, 120/208/240V AC, 7 to 15 A, 3 Switches Included (MPN EZS21W114H3A6A8AC10E15A17G)
SJE-RHOMBUS
SJE-RHOMBUS Control Panel: Simplex, Single Phase, 120/208/240V AC, 7 to 15 A, 3 Switches Included (MPN EZS21W114H3A6A8AC10E15A17G)
Single-phase, 120V AC pump control panel rated 0 to 15 A with demand dose dosing schedule. Includes one switch, visual alert output, and non-reversing operation. Outdoor-rated enclosure suitable for use in wastewater or effluent pumping systems
SJE-RHOMBUS