We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

SIEMENS NEMA Enclosed Non-Reversing Starter with Electronic Overload - Enclosed Non-Reversing Starters with Electronic Overloads
SIEMENS NEMAEnclosed Non-Reversing Starters with Electronic Overloads

SIEMENS NEMA Enclosed Non-Reversing Starter with Electronic Overload

The SIEMENS NEMA Magnetic Motor Starter is a non-reversing enclosed starter with an electronic overload, rated for three poles, NEMA Size 0, 18 A, and a 208V AC coil. It features screw terminals, a pilot light, and…

SKU 3G-OTH-130736

Brand
SIEMENS NEMA
Item
Enclosed Non-Reversing Starter with Electronic Overload
Category
Enclosed Non-Reversing Starters with Electronic Overloads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

SIEMENS NEMA
Manufacturer Part Number
14CUA32BD
Type
NEMA Size 0, 18 A
Poles
3
AC Coil
208V

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SIEMENS NEMA Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SIEMENS NEMA Magnetic Motor Starter is a non-reversing enclosed starter with an electronic overload, rated for three poles, NEMA Size 0, 18 A, and a 208V AC coil. It features screw terminals, a pilot light, and one normally open auxiliary contact. This starter is designed for three-phase motor control applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the SIEMENS NEMA Magnetic Motor Starter 14CUA32BD used for?

This enclosed non-reversing starter with electronic overload is used for three-phase motor control in industrial applications such as conveyors, pumps, and fans. It provides reliable starting and overload protection for motors up to 18 A, NEMA Size 0, with a 208V AC coil.

What are the specifications of the SIEMENS NEMA 14CUA32BD starter?

The SIEMENS NEMA Magnetic Motor Starter is non-reversing, 3 poles, NEMA Size 0, rated 18 A, with a 208V AC coil. It includes screw terminals, a pilot light, and one normally open auxiliary contact. The electronic overload is integral, and the enclosure is designed for three-phase motor control.

Where to buy the SIEMENS NEMA 14CUA32BD starter worldwide?

3G Electric supplies the SIEMENS NEMA 14CUA32BD magnetic motor starter worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.

How to install the SIEMENS NEMA 14CUA32BD magnetic motor starter?

Mount the starter on a flat surface, connect three-phase power to the line terminals and the motor to the load terminals. Wire the 208V AC coil to the control circuit. Set the electronic overload according to motor full-load amps. Always follow local electrical codes and the manufacturer's manual.

Used in

Common applications for SIEMENS NEMA
Conveyor systems — SIEMENS NEMA Size 1 starter (27 A) for motor control in material handling
Industrial pumps — SIEMENS NEMA Size 2 starter (45 A) for water and wastewater pumping
HVAC fans — SIEMENS NEMA Size 1-3/4 starter (40 A) for large air handling units
Compressors — SIEMENS NEMA Size 5 starter (270 A) for high-horsepower rotary screw compressors
Machine tools — SIEMENS NEMA Size 1 starter (27 A) for spindle motor starting in CNC equipment
Mixers and agitators — SIEMENS NEMA Size 2 starter (45 A) for chemical processing vessels

SIEMENS NEMA Products

3G Electric supplies SIEMENS NEMA enclosed non-reversing starters with electronic overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This enclosed non-reversing starter with electronic overload is designed for starting and protecting three-phase motors in forward-only applications such as conveyors, pumps, and fans. It features a NEMA Size 0 contactor rated 18 A, a 240V AC coil, and includes screw terminals, one normally open auxiliary contact, and a pilot light. The unit accepts 190-220/220-240V AC supply
SIEMENS NEMA
This enclosed non-reversing starter with electronic overload is designed for starting and protecting three-phase motors in forward-only applications such as conveyors, pumps, and fans. It features a NEMA Size 0 contactor rated 18 A, a 240V AC coil, and includes screw terminals, one normally open auxiliary contact, and a pilot light. The unit accepts 190-220/220-240V AC supply
This enclosed non-reversing starter is NEMA Size 0 with a 18 A rating and 3 poles. It features an electronic overload, a 120V AC coil, a pilot light, screw terminals, and one normally open auxiliary contact. Used for starting and protecting three-phase motors in industrial applications such as conveyors, pumps, fans, and compressors
SIEMENS NEMA
This enclosed non-reversing starter is NEMA Size 0 with a 18 A rating and 3 poles. It features an electronic overload, a 120V AC coil, a pilot light, screw terminals, and one normally open auxiliary contact. Used for starting and protecting three-phase motors in industrial applications such as conveyors, pumps, fans, and compressors
Enclosed non-reversing starter with electronic overload for three-phase motor control. Features 3 poles, NEMA Size 0, 18 A rating, and 480V AC coil. Includes screw terminals, pilot light, and two 1NO auxiliary contacts. Suitable for industrial motor starting and overload protection
SIEMENS NEMA
Enclosed non-reversing starter with electronic overload for three-phase motor control. Features 3 poles, NEMA Size 0, 18 A rating, and 480V AC coil. Includes screw terminals, pilot light, and two 1NO auxiliary contacts. Suitable for industrial motor starting and overload protection
This enclosed non-reversing starter provides motor starting and overload protection for three-phase motors up to 18 A. It features a NEMA Size 0 contactor, electronic overload relay, 208V AC coil, pilot light, and screw terminals. Typical applications include conveyors, pumps, and fans requiring reliable control
SIEMENS NEMA
This enclosed non-reversing starter provides motor starting and overload protection for three-phase motors up to 18 A. It features a NEMA Size 0 contactor, electronic overload relay, 208V AC coil, pilot light, and screw terminals. Typical applications include conveyors, pumps, and fans requiring reliable control
This enclosed non-reversing starter features an electronic overload relay for motor protection. It is rated NEMA Size 0, 18 A, with 3 poles and a 240V AC coil. The unit includes screw terminals, a pilot light, and one normally open auxiliary contact. Typical applications include starting and protecting three-phase motors in industrial settings such as conveyors, pumps, and fans
SIEMENS NEMA
This enclosed non-reversing starter features an electronic overload relay for motor protection. It is rated NEMA Size 0, 18 A, with 3 poles and a 240V AC coil. The unit includes screw terminals, a pilot light, and one normally open auxiliary contact. Typical applications include starting and protecting three-phase motors in industrial settings such as conveyors, pumps, and fans
Three-pole enclosed non-reversing motor starter with NEMA Size 0 contactor rated 18 A. Includes electronic overload, 1NO auxiliary contact, screw terminals, and pilot light. Coil voltage 208V AC. Suitable for starting and stopping three-phase motors in industrial applications
SIEMENS NEMA
Three-pole enclosed non-reversing motor starter with NEMA Size 0 contactor rated 18 A. Includes electronic overload, 1NO auxiliary contact, screw terminals, and pilot light. Coil voltage 208V AC. Suitable for starting and stopping three-phase motors in industrial applications

More from SIEMENS NEMA

View all SIEMENS NEMA parts
Three-pole NEMA Size 1 enclosed non-reversing magnetic motor starter rated 27 A with a 208V AC coil. Includes electronic overload protection, pilot light, screw terminals, and two 1NO auxiliary contacts. Suitable for starting and stopping three-phase motors in industrial applications such as conveyors, pumps, compressors, and fans
SIEMENS NEMA
Three-pole NEMA Size 1 enclosed non-reversing magnetic motor starter rated 27 A with a 208V AC coil. Includes electronic overload protection, pilot light, screw terminals, and two 1NO auxiliary contacts. Suitable for starting and stopping three-phase motors in industrial applications such as conveyors, pumps, compressors, and fans
This enclosed non-reversing starter features electronic overload protection and is rated for 40 A at NEMA Size 1-3/4. It includes a 208V AC coil, three poles, screw terminals, a pilot light, and one normally open auxiliary contact. Suitable for three-phase motor control applications such as conveyors, pumps, and compressors
SIEMENS NEMA
This enclosed non-reversing starter features electronic overload protection and is rated for 40 A at NEMA Size 1-3/4. It includes a 208V AC coil, three poles, screw terminals, a pilot light, and one normally open auxiliary contact. Suitable for three-phase motor control applications such as conveyors, pumps, and compressors
Three-pole enclosed non-reversing starter with electronic overload protection. NEMA Size 2, rated 45 A, with a 240V AC coil. Includes screw terminals, a pilot light, and one normally open auxiliary contact. Suitable for starting and protecting three-phase motors in applications such as pumps, conveyors, and fans
SIEMENS NEMA
Three-pole enclosed non-reversing starter with electronic overload protection. NEMA Size 2, rated 45 A, with a 240V AC coil. Includes screw terminals, a pilot light, and one normally open auxiliary contact. Suitable for starting and protecting three-phase motors in applications such as pumps, conveyors, and fans
This enclosed non-reversing starter with electronic overload is NEMA Size 1, rated 27 A, with 3 poles and a 480V AC coil. It includes screw terminals, one normally open auxiliary contact, and a pilot light. Designed for three-phase motor control in industrial applications such as pumps, conveyors, and compressors
SIEMENS NEMA
This enclosed non-reversing starter with electronic overload is NEMA Size 1, rated 27 A, with 3 poles and a 480V AC coil. It includes screw terminals, one normally open auxiliary contact, and a pilot light. Designed for three-phase motor control in industrial applications such as pumps, conveyors, and compressors
NEMA Size 1 enclosed non-reversing starter with electronic overload, rated 27 A, 3 poles, 208V AC coil. Includes screw terminals, pilot light, and two 1NO auxiliary contacts. Used for starting and stopping three-phase motors in industrial applications such as pumps, conveyors, and HVAC systems
SIEMENS NEMA
NEMA Size 1 enclosed non-reversing starter with electronic overload, rated 27 A, 3 poles, 208V AC coil. Includes screw terminals, pilot light, and two 1NO auxiliary contacts. Used for starting and stopping three-phase motors in industrial applications such as pumps, conveyors, and HVAC systems
NEMA Size 5 enclosed non-reversing starter with electronic overload, rated 270 A, 3 poles, and 120V AC/DC coil. Includes screw terminals, one normally open auxiliary contact, and a pilot light. Used for starting and protecting three-phase motors in industrial applications
SIEMENS NEMA
NEMA Size 5 enclosed non-reversing starter with electronic overload, rated 270 A, 3 poles, and 120V AC/DC coil. Includes screw terminals, one normally open auxiliary contact, and a pilot light. Used for starting and protecting three-phase motors in industrial applications
This enclosed non-reversing starter with electronic overload is designed for starting and protecting three-phase motors. It features NEMA Size 1, 27 A rating, 3 poles, and a 240V AC coil. The unit includes screw terminals, a pilot light, and two 1NO auxiliary contacts. Typical applications include motor control for pumps, conveyors, and fans in industrial environments
SIEMENS NEMA
This enclosed non-reversing starter with electronic overload is designed for starting and protecting three-phase motors. It features NEMA Size 1, 27 A rating, 3 poles, and a 240V AC coil. The unit includes screw terminals, a pilot light, and two 1NO auxiliary contacts. Typical applications include motor control for pumps, conveyors, and fans in industrial environments
NEMA Size 4 enclosed non-reversing motor starter with electronic overload protection. Rated 135 A, 3 poles, 208V AC coil. Includes screw terminals, pilot light, and two 1NO auxiliary contacts. For three-phase motor control applications requiring non-reversing starting
SIEMENS NEMA
NEMA Size 4 enclosed non-reversing motor starter with electronic overload protection. Rated 135 A, 3 poles, 208V AC coil. Includes screw terminals, pilot light, and two 1NO auxiliary contacts. For three-phase motor control applications requiring non-reversing starting