We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Siemens Line Volt Mechanical Tstat: 35° to 45°F, Steel, Fixed, 12°F - Freeze Protection Indoor Single-Stage Controls
SiemensFreeze Protection Indoor Single-Stage Controls

Siemens Line Volt Mechanical Tstat: 35° to 45°F, Steel, Fixed, 12°F

The SIEMENS Line Volt Mechanical Tstat is a freeze protection indoor single-stage control with a fixed 12°F temperature differential and a control range of 35° to 45°F. It features a steel enclosure, SPDT switch…

SKU 3G-OTH-67803

Brand
Siemens
Item
Line Volt Mechanical Tstat: 35° to 45°F, Steel, Fixed, 12°F
Category
Freeze Protection Indoor Single-Stage Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

Siemens
Manufacturer Part Number
134-1510
Type
Steel, Fixed, 12°F
AC Volt
120 to 240V
Voltage
120 to 240V AC
Differential Type
Fixed
Enclosure Material
Steel
Switch Type/Action
SPDT, Open/Close on Rise
Temperature Differential
12°F
Temperature Control Range
35° to 45°F
Capillary Length/Bulb Diameter
4 ft Capillary, 20 ft x 1/8 in Bulb
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Siemens Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SIEMENS Line Volt Mechanical Tstat is a freeze protection indoor single-stage control with a fixed 12°F temperature differential and a control range of 35° to 45°F. It features a steel enclosure, SPDT switch action (open/close on rise), and operates on 120 to 240V AC. The unit includes a 4 ft capillary and a 20 ft x 1/8 in bulb.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the SIEMENS 134-1510 line volt mechanical thermostat used for?

The SIEMENS 134-1510 is a freeze protection indoor single-stage control. It prevents pipes and equipment from freezing by activating heating systems when temperatures drop between 35° and 45°F, with a fixed 12°F differential. Common in HVAC, refrigeration, and industrial building applications.

What are the specifications of the SIEMENS 134-1510 thermostat?

The SIEMENS 134-1510 has a temperature control range of 35° to 45°F, a fixed 12°F differential, SPDT switch action (open/close on rise), and operates on 120 to 240V AC. It features a steel enclosure, a 4 ft capillary, and a 20 ft x 1/8 in bulb.

Where to buy the SIEMENS 134-1510 thermostat worldwide?

3G Electric supplies the SIEMENS 134-1510 line volt mechanical thermostat to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this freeze protection control.

How to install the SIEMENS 134-1510 freeze protection thermostat?

Mount the SIEMENS 134-1510 in a dry indoor location with the bulb positioned to sense the coldest air near protected pipes. Wire per the SPDT diagram for 120 to 240V AC, ensuring the capillary is not kinked. Always follow local electrical codes and the manufacturer's installation manual.

Used in

Common applications for Siemens
District cooling plants — LME73 + RWF55 for condenser-water modulation
Inflight catering and food-processing steam boilers — LMG22 with SQN90 air-fuel cross-damper
Hospital steam-plant redundancy — LME41 with QRA2 UV flame detection for dual-fuel boilers
Semiconductor fab process heat — LME23 and SKP55 gas valves on hot-oil heater skids
Container-terminal reefer-deck heating — LMG22 retrofit onto legacy burner racks

Siemens Products

3G Electric supplies Siemens freeze protection indoor single-stage controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
SIEMENS Line Volt Mechanical Tstat: Heat or Cool, Auto, 40° to 95°F, Concealed Dial/Exposed Dial (MPN 134-1084). Key specifications — Application: Heat or Cool; System Settings: Auto; Switch Type/Action: SPDT, Open/Close on Rise; Temperature Control Range: 40° to 95°F; Stages: 1H/1C; Voltage: 120 to 240V AC; Brand: SIEMENS; Control Type: Concealed Dial.
Siemens
SIEMENS Line Volt Mechanical Tstat: Heat or Cool, Auto, 40° to 95°F, Concealed Dial/Exposed Dial (MPN 134-1084). Key specifications — Application: Heat or Cool; System Settings: Auto; Switch Type/Action: SPDT, Open/Close on Rise; Temperature Control Range: 40° to 95°F; Stages: 1H/1C; Voltage: 120 to 240V AC; Brand: SIEMENS; Control Type: Concealed Dial.
SIEMENS Electric Surface Mounted Thermostat: Heat and Cool, 50° to 200°F (MPN 141-0522). Key specifications — Control Type: Screwdriver; Switch Type/Action: SPDT, Open/Close on Rise; Temperature Control Range: 50° to 200°F; Temperature Differential: 4°F; Voltage: 120 to 240V AC; Brand: SIEMENS.
Siemens
SIEMENS Electric Surface Mounted Thermostat: Heat and Cool, 50° to 200°F (MPN 141-0522). Key specifications — Control Type: Screwdriver; Switch Type/Action: SPDT, Open/Close on Rise; Temperature Control Range: 50° to 200°F; Temperature Differential: 4°F; Voltage: 120 to 240V AC; Brand: SIEMENS.
Siemens
Siemens
SIEMENS Pneumatic Mechanical Thermostat: 45° to 85°F, Direct and Reverse, 192-209. Key specifications — Temperature Control Range: 45° to 85°F; Thermostat Action: Direct and Reverse; Brand: SIEMENS.
JOHNSON CONTROLS Line Volt Mechanical Tstat: 35° to 45°F, Steel, Fixed, 12°F, 24 to 277V AC Volt (MPN A11B-1C). Key specifications — Switch Type/Action: SPST, Close on Rise; Temperature Control Range: 35° to 45°F; Temperature Differential: 12°F; Voltage: 24 to 277V AC; Capillary Length/Bulb Diameter: 4 ft Capillary, 20 ft x 1/8 in Bulb; Brand: JOHNSON CONTROLS; Differential Type: Fixed; Enclosure Material: Steel.
JOHNSON CONTROLS
JOHNSON CONTROLS Line Volt Mechanical Tstat: 35° to 45°F, Steel, Fixed, 12°F, 24 to 277V AC Volt (MPN A11B-1C). Key specifications — Switch Type/Action: SPST, Close on Rise; Temperature Control Range: 35° to 45°F; Temperature Differential: 12°F; Voltage: 24 to 277V AC; Capillary Length/Bulb Diameter: 4 ft Capillary, 20 ft x 1/8 in Bulb; Brand: JOHNSON CONTROLS; Differential Type: Fixed; Enclosure Material: Steel.
JOHNSON CONTROLS Line Volt Mechanical Tstat: 35° to 45°F, Steel, Manual Reset, 12°F (MPN A11A-1C). Key specifications — Switch Type/Action: SPST, Close on Rise; Temperature Control Range: 35° to 45°F; Temperature Differential: 12°F; Voltage: 24 to 277V AC; Capillary Length/Bulb Diameter: 4 ft Capillary, 20 ft x 1/8 in Bulb; Brand: JOHNSON CONTROLS; Differential Type: Manual Reset; Enclosure Material: Steel.
JOHNSON CONTROLS
JOHNSON CONTROLS Line Volt Mechanical Tstat: 35° to 45°F, Steel, Manual Reset, 12°F (MPN A11A-1C). Key specifications — Switch Type/Action: SPST, Close on Rise; Temperature Control Range: 35° to 45°F; Temperature Differential: 12°F; Voltage: 24 to 277V AC; Capillary Length/Bulb Diameter: 4 ft Capillary, 20 ft x 1/8 in Bulb; Brand: JOHNSON CONTROLS; Differential Type: Manual Reset; Enclosure Material: Steel.
SIEMENS Line Volt Mechanical Thermostat: Surface Mount, Close on Rise/Open on Rise, 30 to 110°F (MPN 141-0520). Key specifications — Switch Action: Open on Rise; Temperature Control Range: 30 to 110°F; Temperature Differential: 3.5 to 14°F; Brand: SIEMENS.
Siemens
SIEMENS Line Volt Mechanical Thermostat: Surface Mount, Close on Rise/Open on Rise, 30 to 110°F (MPN 141-0520). Key specifications — Switch Action: Open on Rise; Temperature Control Range: 30 to 110°F; Temperature Differential: 3.5 to 14°F; Brand: SIEMENS.

More from Siemens

View all Siemens parts
SIEMENS Line Volt Mechanical Tstat: 35° to 45°F, Steel, Fixed, 12°F, 120 to 240V AC Volt (MPN 134-1511). Key specifications — Switch Type/Action: SPDT, Open/Close on Rise; Temperature Control Range: 35° to 45°F; Temperature Differential: 12°F; Voltage: 120 to 240V AC; Capillary Length/Bulb Diameter: 4 ft Capillary, 20 ft x 1/8 in Bulb; Brand: SIEMENS; Differential Type: Fixed; Enclosure Material: Steel.
Siemens
SIEMENS Line Volt Mechanical Tstat: 35° to 45°F, Steel, Fixed, 12°F, 120 to 240V AC Volt (MPN 134-1511). Key specifications — Switch Type/Action: SPDT, Open/Close on Rise; Temperature Control Range: 35° to 45°F; Temperature Differential: 12°F; Voltage: 120 to 240V AC; Capillary Length/Bulb Diameter: 4 ft Capillary, 20 ft x 1/8 in Bulb; Brand: SIEMENS; Differential Type: Fixed; Enclosure Material: Steel.
SIEMENS Line Volt Mechanical Tstat: 15° to 55°F, Steel, Fixed, 5°F, 120 to 240V AC Volt (MPN 134-1504). Key specifications — Switch Type/Action: DPST, Open/Close on Rise; Temperature Control Range: 15° to 55°F; Temperature Differential: 5°F; Voltage: 120 to 240V AC; Capillary Length/Bulb Diameter: 20 ft Capillary, 20 ft x 1/8 in Bulb; Brand: SIEMENS; Differential Type: Fixed; Enclosure Material: Steel.
Siemens
SIEMENS Line Volt Mechanical Tstat: 15° to 55°F, Steel, Fixed, 5°F, 120 to 240V AC Volt (MPN 134-1504). Key specifications — Switch Type/Action: DPST, Open/Close on Rise; Temperature Control Range: 15° to 55°F; Temperature Differential: 5°F; Voltage: 120 to 240V AC; Capillary Length/Bulb Diameter: 20 ft Capillary, 20 ft x 1/8 in Bulb; Brand: SIEMENS; Differential Type: Fixed; Enclosure Material: Steel.