We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Siemens 14CUA32AA Non-Reversing Starter with Electronic Overload - Non-Reversing Starters with Electronic Overloads
SiemensNon-Reversing Starters with Electronic Overloads

Siemens 14CUA32AA Non-Reversing Starter with Electronic Overload

The SIEMENS NEMA Magnetic Motor Starter is a non-reversing, three-pole starter with electronic overloads, NEMA Size 0, rated 18 A. It features a dual-voltage coil (110-120/220-240V AC), a pilot light, and one…

SKU 3G-OTH-40775

Brand
Siemens
Item
14CUA32AA Non-Reversing Starter with Electronic Overload
Category
Non-Reversing Starters with Electronic Overloads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Siemens
Manufacturer Part Number
14CUA32AA
Phase
Three
Coil Voltage
110-120/220-240V AC
Signaling Features
Pilot Light
Auxiliary Contact Form
1NO
Thermal Units Required
None (Not Applicable to Electronic Overloads)
Terminal Connection Type
Screw Terminals
Auxiliary Contacts Included
1NO

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Siemens Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SIEMENS NEMA Magnetic Motor Starter is a non-reversing, three-pole starter with electronic overloads, NEMA Size 0, rated 18 A. It features a dual-voltage coil (110-120/220-240V AC), a pilot light, and one normally open auxiliary contact. This three-phase starter uses screw terminals and requires no thermal units, as it is designed for electronic overload protection.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the SIEMENS 14CUA32AA magnetic motor starter used for?

The SIEMENS 14CUA32AA is a NEMA Size 0, non-reversing magnetic motor starter used to start and stop three-phase motors in industrial applications such as conveyors, pumps, and compressors. Its electronic overload provides adjustable protection, and the built-in pilot light indicates motor status.

What are the specifications of the SIEMENS 14CUA32AA motor starter?

This SIEMENS starter is three-pole, NEMA Size 0, rated 18 A, with a dual-voltage coil (110-120/220-240V AC). It includes one normally open auxiliary contact, a pilot light, and screw terminals. It uses electronic overload protection and requires no thermal units.

Where to buy the SIEMENS 14CUA32AA motor starter worldwide?

3G Electric supplies the SIEMENS 14CUA32AA motor starter worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for a quote and lead time on this genuine SIEMENS part.

How to select the correct overload for the SIEMENS 14CUA32AA starter?

The SIEMENS 14CUA32AA uses an electronic overload relay, so no separate thermal units are needed. To select the correct overload setting, match the motor full-load amperage (FLA) to the adjustable range of the electronic overload module. Consult the motor nameplate and SIEMENS documentation for precise adjustment.

Used in

Common applications for Siemens
District cooling plants — LME73 + RWF55 for condenser-water modulation
Inflight catering and food-processing steam boilers — LMG22 with SQN90 air-fuel cross-damper
Hospital steam-plant redundancy — LME41 with QRA2 UV flame detection for dual-fuel boilers
Semiconductor fab process heat — LME23 and SKP55 gas valves on hot-oil heater skids
Container-terminal reefer-deck heating — LMG22 retrofit onto legacy burner racks

Siemens Products

3G Electric supplies Siemens non-reversing starters with electronic overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Three-pole non-reversing magnetic motor starter with electronic overload relay, NEMA Size 0, rated 18 A. Coil voltage 110-120/220-240V AC dual-range. Includes pilot light and one normally open auxiliary contact. Screw terminals. Used for starting and stopping three-phase AC motors in applications such as pumps, fans, conveyors, and compressors
Siemens
Three-pole non-reversing magnetic motor starter with electronic overload relay, NEMA Size 0, rated 18 A. Coil voltage 110-120/220-240V AC dual-range. Includes pilot light and one normally open auxiliary contact. Screw terminals. Used for starting and stopping three-phase AC motors in applications such as pumps, fans, conveyors, and compressors
This Siemens non-reversing magnetic motor starter is a three-pole NEMA Size 0 unit rated 18 A. It features an electronic overload relay that eliminates the need for thermal units, a dual-range coil voltage of 110-120/220-240V AC, screw terminals, one normally open auxiliary contact, and a built-in pilot light. Typical applications include starting and stopping three-phase AC motors in industrial machinery such as pumps, fans, and conveyors
Siemens
This Siemens non-reversing magnetic motor starter is a three-pole NEMA Size 0 unit rated 18 A. It features an electronic overload relay that eliminates the need for thermal units, a dual-range coil voltage of 110-120/220-240V AC, screw terminals, one normally open auxiliary contact, and a built-in pilot light. Typical applications include starting and stopping three-phase AC motors in industrial machinery such as pumps, fans, and conveyors
Three-pole non-reversing magnetic motor starter with electronic overload protection, NEMA Size 00, rated 9 A. Coil voltage dual-range 110-120/220-240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Screw terminal connections. Suitable for starting and stopping three-phase AC motors in industrial applications such as conveyors, pumps, fans, and compressors
Siemens
Three-pole non-reversing magnetic motor starter with electronic overload protection, NEMA Size 00, rated 9 A. Coil voltage dual-range 110-120/220-240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Screw terminal connections. Suitable for starting and stopping three-phase AC motors in industrial applications such as conveyors, pumps, fans, and compressors
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated 27 A at NEMA Size 1. Coil voltage dual-rated 110-120/220-240V AC. Includes pilot light and one normally open auxiliary contact. Screw terminals. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and compressors
Siemens
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated 27 A at NEMA Size 1. Coil voltage dual-rated 110-120/220-240V AC. Includes pilot light and one normally open auxiliary contact. Screw terminals. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and compressors
This Siemens non-reversing magnetic motor starter is a three-pole NEMA Size 00 unit rated at 9 A, featuring an electronic overload for motor protection. It operates on a dual-range coil voltage of 110-120/220-240V AC and includes a pilot light for status indication and one normally open auxiliary contact. Screw terminals facilitate wiring connections. Typical applications include starting and stopping three-phase AC motors in industrial settings such as conveyors, pumps, and compressors
Siemens
This Siemens non-reversing magnetic motor starter is a three-pole NEMA Size 00 unit rated at 9 A, featuring an electronic overload for motor protection. It operates on a dual-range coil voltage of 110-120/220-240V AC and includes a pilot light for status indication and one normally open auxiliary contact. Screw terminals facilitate wiring connections. Typical applications include starting and stopping three-phase AC motors in industrial settings such as conveyors, pumps, and compressors
Non-reversing magnetic motor starter for three-phase AC motors. Includes electronic overload protection, pilot light, and one normally open auxiliary contact. Rated 27 A, NEMA Size 1, with dual-range coil voltage 110-120/220-240V AC. Screw terminals. Suitable for starting and protecting motors in industrial applications such as pumps, fans, and conveyors
Siemens
Non-reversing magnetic motor starter for three-phase AC motors. Includes electronic overload protection, pilot light, and one normally open auxiliary contact. Rated 27 A, NEMA Size 1, with dual-range coil voltage 110-120/220-240V AC. Screw terminals. Suitable for starting and protecting motors in industrial applications such as pumps, fans, and conveyors

More from Siemens

View all Siemens parts
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated 27 A and NEMA Size 1. Coil voltage is 380-440/440-480V AC. Includes a pilot light and one normally open auxiliary contact. Screw terminals. Suitable for starting and protecting three-phase motors in industrial applications such as conveyors, pumps, and compressors
Siemens
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated 27 A and NEMA Size 1. Coil voltage is 380-440/440-480V AC. Includes a pilot light and one normally open auxiliary contact. Screw terminals. Suitable for starting and protecting three-phase motors in industrial applications such as conveyors, pumps, and compressors
SIEMENS NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 0, 18 A, 120V AC Coil (MPN 14CUA32AF)
Siemens
SIEMENS NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 0, 18 A, 120V AC Coil (MPN 14CUA32AF)
Three-pole non-reversing magnetic motor starter with electronic overload protection, NEMA Size 1, rated 27 A. Coil voltage dual-range 110-120/220-240V AC. Includes screw terminals, pilot light, and one normally open auxiliary contact. Electronic overload eliminates need for thermal units. Suitable for starting and stopping three-phase AC motors in industrial applications such as conveyors, pumps, and compressors
Siemens
Three-pole non-reversing magnetic motor starter with electronic overload protection, NEMA Size 1, rated 27 A. Coil voltage dual-range 110-120/220-240V AC. Includes screw terminals, pilot light, and one normally open auxiliary contact. Electronic overload eliminates need for thermal units. Suitable for starting and stopping three-phase AC motors in industrial applications such as conveyors, pumps, and compressors
SIEMENS NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 00, 9 A, 208V AC Coil (MPN 14BUC32AD)
Siemens
SIEMENS NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 00, 9 A, 208V AC Coil (MPN 14BUC32AD)
Three-pole non-reversing magnetic motor starter with built-in electronic overload protection. Rated 9 A, NEMA Size 00, for three-phase motors. Coil voltage dual-range 110-120/220-240V AC. Includes pilot light and one normally open auxiliary contact. Screw terminal connections. Suitable for starting and stopping motors in industrial machinery, conveyors, and pumps
Siemens
Three-pole non-reversing magnetic motor starter with built-in electronic overload protection. Rated 9 A, NEMA Size 00, for three-phase motors. Coil voltage dual-range 110-120/220-240V AC. Includes pilot light and one normally open auxiliary contact. Screw terminal connections. Suitable for starting and stopping motors in industrial machinery, conveyors, and pumps
SIEMENS NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 1, 27 A, 208V AC Coil (MPN 14DUD32AD)
Siemens
SIEMENS NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 1, 27 A, 208V AC Coil (MPN 14DUD32AD)
Three-pole non-reversing magnetic motor starter rated 18 A at NEMA Size 0. Features an electronic overload, dual-range coil voltage 110-120/220-240V AC, pilot light, one normally open auxiliary contact, and screw terminals. No thermal units required. Used for starting and stopping three-phase motors in industrial motor control applications
Siemens
Three-pole non-reversing magnetic motor starter rated 18 A at NEMA Size 0. Features an electronic overload, dual-range coil voltage 110-120/220-240V AC, pilot light, one normally open auxiliary contact, and screw terminals. No thermal units required. Used for starting and stopping three-phase motors in industrial motor control applications
This Siemens non-reversing motor starter is NEMA Size 0, rated 18 A, with three poles and a 208V AC coil. It includes a pilot light, one normally open auxiliary contact, and screw terminals. The electronic overload eliminates the need for separate thermal units. Typical applications include starting and protecting three-phase motors in conveyors, pumps, and fans
Siemens
This Siemens non-reversing motor starter is NEMA Size 0, rated 18 A, with three poles and a 208V AC coil. It includes a pilot light, one normally open auxiliary contact, and screw terminals. The electronic overload eliminates the need for separate thermal units. Typical applications include starting and protecting three-phase motors in conveyors, pumps, and fans