We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

SHAT-R-SHIELD 010HY50FLFREMYHZ00SCH001 LED Flood Hazardous - LED Flood Hazardous Location Light Fixtures
SHAT-R-SHIELDLED Flood Hazardous Location Light Fixtures

SHAT-R-SHIELD 010HY50FLFREMYHZ00SCH001 LED Flood Hazardous

The SHAT-R-SHIELD Hazardous Light Fixture is an LED flood hazardous location light fixture rated for Class I, Div 2, Groups A, B, C, D. It delivers 3,335 lumens at 4000K color temperature, consuming 24 W from a 120…

SKU 3G-OTH-388604

Brand
SHAT-R-SHIELD
Item
010HY50FLFREMYHZ00SCH001 LED Flood Hazardous
Category
LED Flood Hazardous Location Light Fixtures
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

SHAT-R-SHIELD
Manufacturer Part Number
010HY50FLFREMYHZ00SCH001
Voltage
120 to 277V AC
Color Temperature
4000K
Hazardous Location Rating
Class I, Div 2, Group A, B, C, D

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SHAT-R-SHIELD Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SHAT-R-SHIELD Hazardous Light Fixture is an LED flood hazardous location light fixture rated for Class I, Div 2, Groups A, B, C, D. It delivers 3,335 lumens at 4000K color temperature, consuming 24 W from a 120 to 277V AC supply.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the SHAT-R-SHIELD Hazardous Light Fixture used for?

This LED flood fixture is designed for hazardous locations classified as Class I, Division 2, Groups A, B, C, D. It provides safe, energy-efficient illumination in environments with flammable gases or vapors, such as oil refineries, chemical plants, and fuel storage areas.

What are the specifications of the SHAT-R-SHIELD Hazardous Light Fixture?

The fixture delivers 3,335 lumens at 4000K color temperature, consumes 24 W, and operates on 120 to 277V AC. It carries a hazardous location rating of Class I, Div 2, Groups A, B, C, D. The manufacturer part number is 010HY50FLFREMYHZ00SCH001.

Where to buy the SHAT-R-SHIELD Hazardous Light Fixture worldwide?

3G Electric supplies the SHAT-R-SHIELD Hazardous Light Fixture worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.

How to install the SHAT-R-SHIELD Hazardous Light Fixture?

Installation must follow the National Electrical Code (NEC) and local regulations for Class I, Div 2 locations. Ensure the fixture is securely mounted, supply voltage matches 120 to 277V AC, and all connections are sealed to prevent gas ingress. Consult a qualified electrician.

Used in

Common applications for SHAT-R-SHIELD
Oil and gas refineries — SHAT-R-SHIELD hazardous location LED flood fixtures (Class I, Div 2) for lighting in areas with flammable gases.
Food processing plants — SHAT-R-SHIELD shatter-resistant fluorescent T8 U-bend lamps for cleanroom or washdown areas.
Chemical manufacturing — SHAT-R-SHIELD LED flood fixtures with T4 temperature code for environments with combustible dust.
Warehousing and logistics — SHAT-R-SHIELD stanchion-mount LED hazardous location fixtures for high-bay lighting in dusty conditions.
Animal husbandry — SHAT-R-SHIELD 250W R40 incandescent heat lamps for brooding or warming applications.
Pharmaceutical facilities — SHAT-R-SHIELD A15 frosted incandescent bulbs for general lighting where glass containment is required.

SHAT-R-SHIELD Products

3G Electric supplies SHAT-R-SHIELD led flood hazardous location light fixtures. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This LED flood light fixture is rated for Class I, Division 2, Groups A, B, C, D hazardous locations. It operates at 120/277V AC, delivers 8200 lumens at 48 W, and has a T4 temperature code with 5000K color temperature. Suitable for wall-mount applications in industrial environments requiring explosion-proof lighting
SHAT-R-SHIELD
This LED flood light fixture is rated for Class I, Division 2, Groups A, B, C, D hazardous locations. It operates at 120/277V AC, delivers 8200 lumens at 48 W, and has a T4 temperature code with 5000K color temperature. Suitable for wall-mount applications in industrial environments requiring explosion-proof lighting
This LED flood light fixture is rated for Class I, Division 2, Groups A, B, C, D hazardous locations. It delivers 10,900 lumens at 60W with a 5000K color temperature and operates on 120/277V AC. The suspended mount design and T4 temperature code make it suitable for environments where flammable gases or vapors may be present
SHAT-R-SHIELD
This LED flood light fixture is rated for Class I, Division 2, Groups A, B, C, D hazardous locations. It delivers 10,900 lumens at 60W with a 5000K color temperature and operates on 120/277V AC. The suspended mount design and T4 temperature code make it suitable for environments where flammable gases or vapors may be present
This LED flood light fixture is rated for Class I, Division 2, Groups A, B, C, D hazardous locations with a T4 temperature code. It operates on 120/277V AC and delivers 8200 lumens at 5000K color temperature. The yoke/trunnion mount allows for adjustable positioning. Suitable for areas where flammable gases or vapors may be present
SHAT-R-SHIELD
This LED flood light fixture is rated for Class I, Division 2, Groups A, B, C, D hazardous locations with a T4 temperature code. It operates on 120/277V AC and delivers 8200 lumens at 5000K color temperature. The yoke/trunnion mount allows for adjustable positioning. Suitable for areas where flammable gases or vapors may be present
This LED flood light fixture is rated for Class I, Division 2, Groups A, B, C, D hazardous locations. It operates at 120/277V AC, delivers 5300 lumens at 5000K color temperature, and consumes 30W. The T4 temperature code and yoke/trunnion mount make it suitable for industrial environments where flammable gases or vapors may be present
SHAT-R-SHIELD
This LED flood light fixture is rated for Class I, Division 2, Groups A, B, C, D hazardous locations. It operates at 120/277V AC, delivers 5300 lumens at 5000K color temperature, and consumes 30W. The T4 temperature code and yoke/trunnion mount make it suitable for industrial environments where flammable gases or vapors may be present
This LED flood light fixture is rated for Class III, Division 1 and 2 hazardous locations. It operates at 120/277V AC, delivers 8200 lumens at 48W, with a 5000K color temperature and T4 temperature code. Suitable for suspended mounting in environments such as textile mills, grain elevators, or woodworking facilities where combustible fibers or flyings are present
SHAT-R-SHIELD
This LED flood light fixture is rated for Class III, Division 1 and 2 hazardous locations. It operates at 120/277V AC, delivers 8200 lumens at 48W, with a 5000K color temperature and T4 temperature code. Suitable for suspended mounting in environments such as textile mills, grain elevators, or woodworking facilities where combustible fibers or flyings are present
This LED flood light fixture is rated for hazardous locations Class I, Division 2, Groups A, B, C, D. It delivers 16,000 lumens at 5000K color temperature, operates on 120/277V AC, and consumes 95W. The suspended mount design and T4 temperature code suit industrial environments where flammable gases or vapors may be present
SHAT-R-SHIELD
This LED flood light fixture is rated for hazardous locations Class I, Division 2, Groups A, B, C, D. It delivers 16,000 lumens at 5000K color temperature, operates on 120/277V AC, and consumes 95W. The suspended mount design and T4 temperature code suit industrial environments where flammable gases or vapors may be present

More from SHAT-R-SHIELD

View all SHAT-R-SHIELD parts
This LED flood light fixture is rated for hazardous locations Class III, Divisions 1 and 2, suitable for environments with combustible fibers or flyings. It operates at 120/277V AC, delivers 10,900 lumens at 5000K color temperature, and carries a T4 temperature code. Designed for stanchion mounting, it provides area lighting in settings such as textile mills or grain elevators
SHAT-R-SHIELD
This LED flood light fixture is rated for hazardous locations Class III, Divisions 1 and 2, suitable for environments with combustible fibers or flyings. It operates at 120/277V AC, delivers 10,900 lumens at 5000K color temperature, and carries a T4 temperature code. Designed for stanchion mounting, it provides area lighting in settings such as textile mills or grain elevators
This LED flood light fixture is rated for Class III, Division 1 and 2 hazardous locations where combustible fibers or flyings may be present. It operates at 120/277V AC, delivering 10,900 lumens at 60 W with a 5000K color temperature and T3C temperature code. The wall-mount design is suitable for environments such as textile mills or grain handling facilities
SHAT-R-SHIELD
This LED flood light fixture is rated for Class III, Division 1 and 2 hazardous locations where combustible fibers or flyings may be present. It operates at 120/277V AC, delivering 10,900 lumens at 60 W with a 5000K color temperature and T3C temperature code. The wall-mount design is suitable for environments such as textile mills or grain handling facilities
This LED flood light fixture is rated for Class II, Division 2, Groups F and G hazardous locations where combustible dust may be present. It operates at 120/277V AC, delivers 5300 lumens at 5000K color temperature, and carries a T3C temperature code. The stanchion mount design allows permanent installation in environments such as grain elevators, flour mills, or chemical plants
SHAT-R-SHIELD
This LED flood light fixture is rated for Class II, Division 2, Groups F and G hazardous locations where combustible dust may be present. It operates at 120/277V AC, delivers 5300 lumens at 5000K color temperature, and carries a T3C temperature code. The stanchion mount design allows permanent installation in environments such as grain elevators, flour mills, or chemical plants
SHAT-R-SHIELD Hazardous Light Fixture: 10,900 lm, 5000K, Yoke/Trunnion Mount, T3C/T4 Temp Code, 60 W (MPN 060HY50STFRVLYHZ00SCH201)
SHAT-R-SHIELD
SHAT-R-SHIELD Hazardous Light Fixture: 10,900 lm, 5000K, Yoke/Trunnion Mount, T3C/T4 Temp Code, 60 W (MPN 060HY50STFRVLYHZ00SCH201)
This LED flood light fixture is rated for Class III, Division 1 and 2 hazardous locations, suitable for environments with combustible fibers or flyings. It operates at 120/277V AC, delivers 5300 lumens at 5000K color temperature, and has a T4 temperature code. The suspended mount design allows for overhead installation in industrial settings
SHAT-R-SHIELD
This LED flood light fixture is rated for Class III, Division 1 and 2 hazardous locations, suitable for environments with combustible fibers or flyings. It operates at 120/277V AC, delivers 5300 lumens at 5000K color temperature, and has a T4 temperature code. The suspended mount design allows for overhead installation in industrial settings
This LED flood light fixture is rated for Class I, Division 2, Groups A, B, C, D hazardous locations. It operates at 120/277V AC, delivers 8,200 lumens at 5000K, and carries a T4 temperature code. The stanchion mount design is suitable for industrial environments where flammable gases or vapors may be present
SHAT-R-SHIELD
This LED flood light fixture is rated for Class I, Division 2, Groups A, B, C, D hazardous locations. It operates at 120/277V AC, delivers 8,200 lumens at 5000K, and carries a T4 temperature code. The stanchion mount design is suitable for industrial environments where flammable gases or vapors may be present
This LED flood light fixture is rated for Class III, Division 1 and 2 hazardous locations where combustible fibers or flyings may be present. It delivers 11,200 lumens at 5000K color temperature with a T4 temperature code. The fixture operates on 120/277V AC and is designed for suspended mount installation in industrial environments
SHAT-R-SHIELD
This LED flood light fixture is rated for Class III, Division 1 and 2 hazardous locations where combustible fibers or flyings may be present. It delivers 11,200 lumens at 5000K color temperature with a T4 temperature code. The fixture operates on 120/277V AC and is designed for suspended mount installation in industrial environments
This LED flood light fixture is rated for Class II, Division 2, Groups F and G hazardous locations where combustible dust may be present. It operates at 120/277V AC, delivers 5300 lumens at 30W, and has a 5000K color temperature with a T4 temperature code. The wall-mount design provides illumination in environments such as grain elevators, flour mills, or chemical plants
SHAT-R-SHIELD
This LED flood light fixture is rated for Class II, Division 2, Groups F and G hazardous locations where combustible dust may be present. It operates at 120/277V AC, delivers 5300 lumens at 30W, and has a 5000K color temperature with a T4 temperature code. The wall-mount design provides illumination in environments such as grain elevators, flour mills, or chemical plants