REICHERT Analog Handheld Refractometer, 137584L0 - Analog Handheld Refractometers
REICHERTAnalog Handheld Refractometers

REICHERT Analog Handheld Refractometer, 137584L0

The REICHERT Refractometer is an analog handheld instrument designed for measuring ethylene glycol concentrations. It offers an accuracy of +/-1° F and a resolution of 0.01 RI, with a refractive index range from…

SKU 3G-OTH-377174

Brand
REICHERT
Item
Analog Handheld Refractometer, 137584L0
Part Number
137584L0
Category
Analog Handheld Refractometers
Available to Order
Also known as:137584L0REICHERT
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

REICHERT
Manufacturer Part Number
137584L0
Type
Auto, Analog, 32°F Auto Temp Compensation - Max
RI/5°F
0.01
Accuracy
+/-1° F
Resolution
0.01 RI
Test Parameters
Ethylene Glycol
Refractive Index - Max
1.402 RI
Refractive Index - Min
1.333 RI
Automatic Temperature Compensation Included
Automatic

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

REICHERT Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The REICHERT Refractometer is an analog handheld instrument designed for measuring ethylene glycol concentrations. It offers an accuracy of +/-1° F and a resolution of 0.01 RI, with a refractive index range from 1.333 RI to 1.402 RI. The unit features automatic temperature compensation for consistent readings.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the REICHERT Refractometer used for?

The REICHERT Refractometer is used to measure ethylene glycol concentrations in industrial cooling and heating systems. It provides accurate freeze-point readings for maintenance and quality control in HVAC, automotive, and process fluid management applications.

What are the specifications of the REICHERT Refractometer 137584L0?

The REICHERT Refractometer 137584L0 is an analog handheld unit with automatic temperature compensation at 32°F. It measures refractive index from 1.333 RI to 1.402 RI with 0.01 RI resolution and accuracy of +/-1°F. It is designed specifically for ethylene glycol testing.

Where to buy the REICHERT Refractometer worldwide?

3G Electric supplies the REICHERT Refractometer worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this ethylene glycol testing instrument.

How to calibrate the REICHERT Refractometer?

To calibrate the REICHERT Refractometer, first clean the prism with distilled water. Apply a few drops of distilled water to the prism, close the cover, and adjust the calibration screw until the scale reads 1.333 RI or 32°F. Wipe clean after calibration.

Used in

Common applications for REICHERT
Automotive service — REICHERT digital refractometer (model 13940017) for brake fluid boiling point testing
HVAC maintenance — REICHERT analog refractometer (model 137584L0) for ethylene glycol concentration in cooling systems
Food processing — REICHERT digital refractometer (model 13940027) for propylene glycol measurement in food-grade antifreeze
Pharmaceutical lab — REICHERT darkfield colony counter (model 13332700) for microbial colony enumeration
Chemical processing — REICHERT digital refractometer (model 13940024) for ethylene glycol freeze point monitoring
Water treatment — REICHERT digital refractometer (model 13940020) for sodium chloride specific gravity in brine solutions
Not sure this is the right part? Photo-identify it

REICHERT Products

3G Electric supplies REICHERT analog handheld refractometers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

More from REICHERT

View all REICHERT parts
Analog handheld refractometer for measuring Brix concentration from 0 to 50 %Brix with 0.25% accuracy and 0.25 Brix resolution. Features automatic temperature compensation. Suitable for field or lab use in food, beverage, and agricultural applications
REICHERT
Analog handheld refractometer for measuring Brix concentration from 0 to 50 %Brix with 0.25% accuracy and 0.25 Brix resolution. Features automatic temperature compensation. Suitable for field or lab use in food, beverage, and agricultural applications

Customer reviews