We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

POWER FIRST Closed-End Crimp Connectors, Nylon, Clear, 22-16 AWG
POWER FIRSTClosed-End Crimp Connectors

POWER FIRST Closed-End Crimp Connectors, Nylon, Clear, 22-16 AWG

The POWER FIRST Closed-End Crimp Connectors are nylon-insulated, tin-plated copper connectors rated for 600 V. They accommodate wire sizes from 22 AWG to 16 AWG, with a maximum wire combination of (2) 22 AWG and a…

SKU 3G-OTH-18693

Brand
POWER FIRST
Item
Closed-End Crimp Connectors, Nylon, Clear, 22-16 AWG
Category
Closed-End Crimp Connectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

POWER FIRST
Color
Clear
Standards
UL/cUL Listed E96029
Contact Finish
Tin
Contact Material
Copper
Maximum Wire Size
16 AWG
Minimum Wire Size
22 AWG
Insulation Material
Nylon
Maximum Wire Combination
(2) 22 AWG
Minimum Wire Combination
(2) 18 AWG

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

POWER FIRST Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The POWER FIRST Closed-End Crimp Connectors are nylon-insulated, tin-plated copper connectors rated for 600 V. They accommodate wire sizes from 22 AWG to 16 AWG, with a maximum wire combination of (2) 22 AWG and a minimum of (2) 18 AWG. These clear connectors are UL/cUL Listed (E96029) for secure, insulated terminations.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What are POWER FIRST Closed-End Crimp Connectors used for?

POWER FIRST Closed-End Crimp Connectors (MPN ) are used to terminate and insulate multiple wires in electrical panels, junction boxes, and industrial control circuits. They are rated for 600 V and accommodate wire sizes from 22 AWG to 16 AWG, making them suitable for general-purpose wiring in manufacturing and facility maintenance.

What are the specifications of POWER FIRST Closed-End Crimp Connectors?

The POWER FIRST Closed-End Crimp Connectors (MPN ) have a tin-plated copper contact, nylon insulation, and a clear color. They are rated for 600 V, accept wire sizes from 22 AWG to 16 AWG, and support a maximum wire combination of (2) 22 AWG and a minimum of (2) 18 AWG. They are UL/cUL Listed under file E96029.

Where to buy POWER FIRST Closed-End Crimp Connectors worldwide?

You can source POWER FIRST Closed-End Crimp Connectors (MPN ) worldwide through 3G Electric. As a global industrial equipment distributor since 1990, 3G Electric handles full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to install POWER FIRST Closed-End Crimp Connectors?

To install POWER FIRST Closed-End Crimp Connectors, strip wires to the recommended length, insert them fully into the connector, and crimp using a ratchet-style crimp tool matched to the wire gauge. Ensure the nylon insulation remains intact for a secure, insulated termination. Always follow UL/cUL guidelines for proper installation.

Used in

Common applications for POWER FIRST
Temporary power distribution — POWER FIRST twist-lock cord adapters (SKU 4FZZ5) for connecting generators to equipment with L5-20R receptacles.
Video surveillance installation — POWER FIRST BNC coaxial connectors (SKU 4JY52) for terminating RG-59 cable runs to cameras or DVRs.
Control panel wiring — POWER FIRST insulated pin terminals (SKU 5UGP4) for terminating signal wires in terminal blocks.
Cable management at events — POWER FIRST 3-channel cable ramps (SKU 32RX19) for protecting audio/video cables across walkways.
Maintenance of industrial machinery — POWER FIRST straight-blade cord adapters (SKU 1FD76) for adapting 5-15P tools to L5-20R outlets.
Electrical panel assembly — POWER FIRST non-insulated pin terminals (SKU 5UGP8) for direct crimp connections in high-density wiring.
Not sure this is the right part? Photo-identify it

POWER FIRST Products

3G Electric supplies POWER FIRST closed-end crimp connectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Nylon-insulated closed-end crimp connector for terminating and insulating multiple wires in electrical junctions, splices, and pigtail connections. Accepts wire combinations from (2) 22 AWG up to 16 AWG maximum. Copper contacts, clear nylon insulation, CSA certified
3M
Nylon-insulated closed-end crimp connector for terminating and insulating multiple wires in electrical junctions, splices, and pigtail connections. Accepts wire combinations from (2) 22 AWG up to 16 AWG maximum. Copper contacts, clear nylon insulation, CSA certified
Closed-end crimp connectors for terminating and insulating multiple wires in electrical panels and junction boxes. Rated 600 V, accept wire sizes from 22 AWG to 14 AWG. Maximum wire combination: (1) 14 AWG; minimum: (4) 22 AWG. Clear nylon insulation, tin-plated copper contacts. Pack of 1,000
PANDUIT
Closed-end crimp connectors for terminating and insulating multiple wires in electrical panels and junction boxes. Rated 600 V, accept wire sizes from 22 AWG to 14 AWG. Maximum wire combination: (1) 14 AWG; minimum: (4) 22 AWG. Clear nylon insulation, tin-plated copper contacts. Pack of 1,000
This wire crimping kit includes a ratcheting crimper designed for non-insulated terminals. It accommodates wire sizes from 10 AWG to 22 AWG, suitable for creating secure connections on solid or stranded wire. Commonly used in electrical maintenance, panel building, and repair work
POWER FIRST
This wire crimping kit includes a ratcheting crimper designed for non-insulated terminals. It accommodates wire sizes from 10 AWG to 22 AWG, suitable for creating secure connections on solid or stranded wire. Commonly used in electrical maintenance, panel building, and repair work
Nylon-insulated closed-end crimp connectors rated for 600 V and wire sizes from 18 AWG to 10 AWG. Tin-plated brass contacts. Accommodates maximum (2) 12 AWG or minimum (4) 18 AWG wires. Clear insulation allows visual inspection. Used for terminating and insulating wire ends in electrical applications such as control panels and junction boxes
PANDUIT
Nylon-insulated closed-end crimp connectors rated for 600 V and wire sizes from 18 AWG to 10 AWG. Tin-plated brass contacts. Accommodates maximum (2) 12 AWG or minimum (4) 18 AWG wires. Clear insulation allows visual inspection. Used for terminating and insulating wire ends in electrical applications such as control panels and junction boxes
Clear nylon-insulated closed-end crimp connector with copper contact. Rated for 600 V, accepts wire sizes from 18 AWG to 10 AWG. Maximum wire combination (2) 14 AWG, minimum (1) 22 AWG. CSA Certified. Used for terminating and insulating multiple wires in electrical junctions and splices
3M
Clear nylon-insulated closed-end crimp connector with copper contact. Rated for 600 V, accepts wire sizes from 18 AWG to 10 AWG. Maximum wire combination (2) 14 AWG, minimum (1) 22 AWG. CSA Certified. Used for terminating and insulating multiple wires in electrical junctions and splices
Closed-end crimp connectors for terminating and insulating multiple wires in a single connection. Rated 600 V, accept wire sizes from 18 AWG to 10 AWG, with maximum combination of (1) 10 AWG and minimum of (6) 18 AWG. Features tin-plated copper contacts and clear nylon insulation. UL 587H E52164 listed. Pack of 500
PANDUIT
Closed-end crimp connectors for terminating and insulating multiple wires in a single connection. Rated 600 V, accept wire sizes from 18 AWG to 10 AWG, with maximum combination of (1) 10 AWG and minimum of (6) 18 AWG. Features tin-plated copper contacts and clear nylon insulation. UL 587H E52164 listed. Pack of 500

More from POWER FIRST

View all POWER FIRST parts
Closed-end crimp connectors with tin-plated copper contacts and clear nylon insulation. Rated 600 V, accepting wire sizes from 12 AWG to 10 AWG with a minimum combination of (2) 14 AWG and maximum of (1) 22 AWG. UL/cUL Listed (E96029). Used for terminating and insulating multiple wires in electrical junctions, control panels, and lighting applications
POWER FIRST
Closed-end crimp connectors with tin-plated copper contacts and clear nylon insulation. Rated 600 V, accepting wire sizes from 12 AWG to 10 AWG with a minimum combination of (2) 14 AWG and maximum of (1) 22 AWG. UL/cUL Listed (E96029). Used for terminating and insulating multiple wires in electrical junctions, control panels, and lighting applications