OAKTON Conductivity Calibration Solution: ACS, 20 mL Volume, Liquid, 15,000 microsiemens

The OAKTON Conductivity Calibration Solution is an ACS-grade liquid conductivity standard with a concentration of 15,000 microsiemens. Supplied in a 20 mL foil pouch (MPN 35653-13, CAS 71-23-8), this solution is used…

SKU 3G-OTH-373223

Also listed as: 3565313 · 35653 13

Brand
OAKTON
Item
Conductivity Calibration Solution: ACS, 20 mL Volume, Liquid, 15,000 microsiemens
Category
Conductivity Standards
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

OAKTON
Manufacturer Part Number
35653-13
Type
Liquid, 15,000 microsiemens, Foil, 20
Form
Liquid
Volume
20 mL
CAS Number
71-23-8
Product Type
Conductivity Calibration Solution
Concentration
15,000 microsiemens
Chemical Grade
ACS
Container Type
Pouch
Container Material
Foil
Chemical Family Type
Solution

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

OAKTON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The OAKTON Conductivity Calibration Solution is an ACS-grade liquid conductivity standard with a concentration of 15,000 microsiemens. Supplied in a 20 mL foil pouch (MPN 35653-13, CAS 71-23-8), this solution is used for calibrating conductivity meters. It is a single-use, ready-to-use calibration standard from the OAKTON brand.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is OAKTON Conductivity Calibration Solution used for?

OAKTON Conductivity Calibration Solution is used to calibrate conductivity meters in laboratories and industrial water-quality testing. The ACS-grade liquid standard at 15,000 microsiemens ensures accurate readings for process control, environmental monitoring, and quality assurance applications.

What are the specifications of OAKTON Conductivity Calibration Solution?

The OAKTON Conductivity Calibration Solution (MPN 35653-13) is an ACS-grade liquid with a concentration of 15,000 microsiemens. It comes in a 20 mL foil pouch, CAS number 71-23-8. This single-use standard is ready to use for calibrating conductivity meters from the OAKTON brand.

Where to buy OAKTON Conductivity Calibration Solution worldwide?

3G Electric supplies OAKTON Conductivity Calibration Solution worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your facility. Contact us to source this ACS-grade 15,000 microsiemens standard for your calibration needs.

How to use OAKTON Conductivity Calibration Solution?

Open the foil pouch and pour the 20 mL liquid into a clean container. Immerse your conductivity meter probe, ensuring no air bubbles. Allow the reading to stabilize, then adjust the meter to 15,000 microsiemens. Discard after single use. Always use fresh solution for accurate calibration.

Used in

Common applications for OAKTON
Water quality testing in chemical plants — OAKTON pH electrodes (e.g., 35660-56) for inline or batch pH measurement
Wastewater treatment monitoring — OAKTON dissolved oxygen meters (e.g., 3564300) for DO/BOD analysis in aeration basins
Laboratory calibration — OAKTON ACS-grade pH buffers (e.g., pH 10.01, pH 1.68) for routine meter standardization
Environmental field sampling — OAKTON handheld DO meters for stream or effluent monitoring
HVAC and storage area monitoring — OAKTON analog thermohygrometers (e.g., 3570010) for temperature and humidity logging
Conductivity measurement in process control — OAKTON conductivity probes (e.g., WD-35608-78) for monitoring solution concentration in plating or rinsing baths

OAKTON Products

3G Electric supplies OAKTON conductivity standards. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
OAKTON Conductivity Calibration Solution: ACS, 500 mL Volume, Liquid, 447 microsiemens, Plastic, 1 (MPN WD-00653-47)
OAKTON
OAKTON Conductivity Calibration Solution: ACS, 500 mL Volume, Liquid, 447 microsiemens, Plastic, 1 (MPN WD-00653-47)
OAKTON Turbidity Calibration Solution Kit: ACS, 60 mL Volume, Liquid, 20, 100, 400, 800 NTU, 1 (MPN 35635-20)
OAKTON
OAKTON Turbidity Calibration Solution Kit: ACS, 60 mL Volume, Liquid, 20, 100, 400, 800 NTU, 1 (MPN 35635-20)
OAKTON Conductivity Meter: Conductivity, ±1% FS, 199.9 uS/cm, 0 uS/cm (MPN 3560415)
OAKTON
OAKTON Conductivity Meter: Conductivity, ±1% FS, 199.9 uS/cm, 0 uS/cm (MPN 3560415)
OAKTON Conductivity Meter: Conductivity, ±1% FS, 199.9 uS/cm, 0 uS/cm, Reagents Sold Separately (MPN 3560410)
OAKTON
OAKTON Conductivity Meter: Conductivity, ±1% FS, 199.9 uS/cm, 0 uS/cm, Reagents Sold Separately (MPN 3560410)

More from OAKTON

View all OAKTON parts
OAKTON Conductivity Calibration Solution: ACS, 20 mL Volume, Liquid, 10 microsiemens, Foil, 20 (MPN WD-35653-09)
OAKTON
OAKTON Conductivity Calibration Solution: ACS, 20 mL Volume, Liquid, 10 microsiemens, Foil, 20 (MPN WD-35653-09)
OAKTON Conductivity Calibration Solution: ACS, 500 mL Volume, Liquid, 23 microsiemens, Plastic, 1 (MPN WD-00653-23)
OAKTON
OAKTON Conductivity Calibration Solution: ACS, 500 mL Volume, Liquid, 23 microsiemens, Plastic, 1 (MPN WD-00653-23)
OAKTON Conductivity Calibration Solution: ACS, 500 mL Volume, Liquid, 2,764microsiemens, Plastic, 1 (MPN WD-00653-20)
OAKTON
OAKTON Conductivity Calibration Solution: ACS, 500 mL Volume, Liquid, 2,764microsiemens, Plastic, 1 (MPN WD-00653-20)
OAKTON Conductivity Calibration Solution: ACS, 500 mL Volume, Liquid, 1,413 microsiemens, Plastic, 1 (MPN WD-00653-18)
OAKTON
OAKTON Conductivity Calibration Solution: ACS, 500 mL Volume, Liquid, 1,413 microsiemens, Plastic, 1 (MPN WD-00653-18)
OAKTON Conductivity Calibration Solution: ACS, 500 mL Volume, Liquid, 84 microsiemens, Plastic, 1 (MPN WD-00653-16)
OAKTON
OAKTON Conductivity Calibration Solution: ACS, 500 mL Volume, Liquid, 84 microsiemens, Plastic, 1 (MPN WD-00653-16)
OAKTON Conductivity Calibration Solution: ACS, 20 mL Volume, Liquid, 447 microsiemens, Foil, 20 (MPN 35653-10)
OAKTON
OAKTON Conductivity Calibration Solution: ACS, 20 mL Volume, Liquid, 447 microsiemens, Foil, 20 (MPN 35653-10)
OAKTON Conductivity Calibration Solution: ACS, 20 mL Volume, Liquid, 1,413 microsiemens, Foil, 20 (MPN 35653-11)
OAKTON
OAKTON Conductivity Calibration Solution: ACS, 20 mL Volume, Liquid, 1,413 microsiemens, Foil, 20 (MPN 35653-11)
OAKTON Conductivity Calibration Solution: ACS, 500 mL Volume, Liquid, 12,880 microsiemens, Glass, 1 (MPN WD-00606-10)
OAKTON
OAKTON Conductivity Calibration Solution: ACS, 500 mL Volume, Liquid, 12,880 microsiemens, Glass, 1 (MPN WD-00606-10)