We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

NEXTTEQ NX213LM C2Cl4 Gas Detection Tube for NX-1000 Pump, 10-Pack - Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
NEXTTEQGas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps

NEXTTEQ NX213LM C2Cl4 Gas Detection Tube for NX-1000 Pump, 10-Pack

The NEXTTEQ NX-1000 Detector Tube (MPN NX213LM) is a C2Cl4 gas detection tube for use with NEXTTEQ NX-1000 pumps, featuring a break-off tip and supplied in a 10-pack. It detects tetrachloroethylene across three…

SKU 3G-OTH-602291

Brand
NEXTTEQ
Item
NX213LM C2Cl4 Gas Detection Tube for NX-1000 Pump, 10-Pack
Category
Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

NEXTTEQ
Manufacturer Part Number
NX213LM
Type
C2Cl4, Gas Detection Tube, With Pump, Break-Off Tip, 10 PK

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

NEXTTEQ Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The NEXTTEQ NX-1000 Detector Tube (MPN NX213LM) is a C2Cl4 gas detection tube for use with NEXTTEQ NX-1000 pumps, featuring a break-off tip and supplied in a 10-pack. It detects tetrachloroethylene across three measurement ranges: 10 to 300 ppm, 2.1 to 21 ppm, and 5 to 150 ppm.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the NEXTTEQ NX-1000 detector tube used for?

The NEXTTEQ NX-1000 detector tube (MPN NX213LM) is used to detect tetrachloroethylene (C2Cl4) gas in industrial environments. It works with NEXTTEQ NX-1000 pumps and provides three measurement ranges: 10 to 300 ppm, 2.1 to 21 ppm, and 5 to 150 ppm.

What are the specifications of the NEXTTEQ NX213LM gas detection tube?

The NEXTTEQ NX213LM is a C2Cl4 gas detection tube with a break-off tip, supplied in a 10-pack. It detects tetrachloroethylene across three ranges: 10 to 300 ppm, 2.1 to 21 ppm, and 5 to 150 ppm. It is designed for use with NEXTTEQ NX-1000 pumps.

Where to buy NEXTTEQ NX-1000 detector tubes worldwide?

3G Electric supplies NEXTTEQ NX-1000 detector tubes worldwide. As a global industrial solutions provider, we handle logistics, customs, and delivery to your location. Contact us to order the NX213LM 10-pack for tetrachloroethylene detection.

How to use the NEXTTEQ NX-1000 gas detection tube?

To use the NEXTTEQ NX-1000 detector tube, break off both tips, insert it into the NX-1000 pump, and draw a sample. Follow the pump's instructions for stroke count and timing. The tube's color change indicates tetrachloroethylene concentration within its specified ranges.

NEXTTEQ Products

3G Electric supplies NEXTTEQ gas detection tubes for use in nextteq nx-1000 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from NEXTTEQ

View all NEXTTEQ parts
Gas detection tube for vinyl chloride (C2H3Cl), supplied in a 5-pack. Designed for use with NEXTTEQ NX-1000 pumps. Provides three measurement ranges: 0.1 to 3 ppm, 0.2 to 6 ppm, and 0.4 to 12 ppm. Used for detecting vinyl chloride in industrial environments
NEXTTEQ
Gas detection tube for vinyl chloride (C2H3Cl), supplied in a 5-pack. Designed for use with NEXTTEQ NX-1000 pumps. Provides three measurement ranges: 0.1 to 3 ppm, 0.2 to 6 ppm, and 0.4 to 12 ppm. Used for detecting vinyl chloride in industrial environments
Gas detection tube for measuring acetaldehyde (C2H4O) concentrations in air or gas streams. Designed for use with NEXTTEQ NX-1000 pumps, with a detection range of 1 to 30 ppm. Supplied in a 10-pack for field measurement via direct-read color change
NEXTTEQ
Gas detection tube for measuring acetaldehyde (C2H4O) concentrations in air or gas streams. Designed for use with NEXTTEQ NX-1000 pumps, with a detection range of 1 to 30 ppm. Supplied in a 10-pack for field measurement via direct-read color change
Gas detection tube for measuring cyclohexanol (C6H12O) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Detection range: 5 to 500 ppm. Supplied in a 10-pack
NEXTTEQ
Gas detection tube for measuring cyclohexanol (C6H12O) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Detection range: 5 to 500 ppm. Supplied in a 10-pack
Gas detection tube for measuring hydrazine (N2H4) concentrations in air or gas streams. Designed for use with NEXTTEQ NX-1000 pumps. Three measurement ranges: 0.05 to 2.5 ppm, 0.1 to 5 ppm, and 0.2 to 10 ppm. Supplied in a 10-pack
NEXTTEQ
Gas detection tube for measuring hydrazine (N2H4) concentrations in air or gas streams. Designed for use with NEXTTEQ NX-1000 pumps. Three measurement ranges: 0.05 to 2.5 ppm, 0.1 to 5 ppm, and 0.2 to 10 ppm. Supplied in a 10-pack
Phosphine (PH3) gas detection tube for use with NEXTTEQ NX-1000 pumps. Supplied in a 10-pack, it provides three measurement ranges: 0.25 to 5 ppm, 0.5 to 10 ppm, and 1 to 20 ppm. Suitable for industrial environments such as fumigation monitoring and grain storage safety
NEXTTEQ
Phosphine (PH3) gas detection tube for use with NEXTTEQ NX-1000 pumps. Supplied in a 10-pack, it provides three measurement ranges: 0.25 to 5 ppm, 0.5 to 10 ppm, and 1 to 20 ppm. Suitable for industrial environments such as fumigation monitoring and grain storage safety
Gas detection tube for hydrogen sulfide (H2S) used with NEXTTEQ NX-1000 pumps. Dual measurement ranges: 1 to 30 ppm and 2 to 60 ppm. Pack of 10 tubes for industrial air monitoring
NEXTTEQ
Gas detection tube for hydrogen sulfide (H2S) used with NEXTTEQ NX-1000 pumps. Dual measurement ranges: 1 to 30 ppm and 2 to 60 ppm. Pack of 10 tubes for industrial air monitoring
Gas detection tube for butadiene (C4H6) used with NEXTTEQ NX-1000 pumps. Measures concentrations from 0.03 to 2.6% vol. Supplied in a 10-pack for industrial safety monitoring in environments where butadiene may be present
NEXTTEQ
Gas detection tube for butadiene (C4H6) used with NEXTTEQ NX-1000 pumps. Measures concentrations from 0.03 to 2.6% vol. Supplied in a 10-pack for industrial safety monitoring in environments where butadiene may be present
Carbon dioxide (CO2) gas detection tube for use with NEXTTEQ NX-1000 pumps. Measures CO2 concentrations from 0.03 to 0.7% vol (100 to 1,500 ppm). Supplied in a 10-pack. Suitable for industrial hygiene, environmental monitoring, and combustion safety checks
NEXTTEQ
Carbon dioxide (CO2) gas detection tube for use with NEXTTEQ NX-1000 pumps. Measures CO2 concentrations from 0.03 to 0.7% vol (100 to 1,500 ppm). Supplied in a 10-pack. Suitable for industrial hygiene, environmental monitoring, and combustion safety checks