We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

NEXTTEQ PH3 Gas Detection Tube for NX-1000 Pumps, 10-Pack (NX204LM) - Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
NEXTTEQGas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps

NEXTTEQ PH3 Gas Detection Tube for NX-1000 Pumps, 10-Pack (NX204LM)

The NEXTTEQ NX-1000 Detector Tube (MPN NX204LM) is a phosphine (PH3) gas detection tube for use with NEXTTEQ NX-1000 pumps, supplied in a 10-pack. It offers three measurement ranges: 0.25 to 5 ppm, 0.5 to 10 ppm, and…

SKU 3G-OTH-602106

Brand
NEXTTEQ
Item
PH3 Gas Detection Tube for NX-1000 Pumps, 10-Pack
Category
Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

NEXTTEQ
Manufacturer Part Number
NX204LM
Type
PH3, Gas Detection Tube, Phosphine ( PH3 ), With Pump, 10 PK

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

NEXTTEQ Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The NEXTTEQ NX-1000 Detector Tube (MPN NX204LM) is a phosphine (PH3) gas detection tube for use with NEXTTEQ NX-1000 pumps, supplied in a 10-pack. It offers three measurement ranges: 0.25 to 5 ppm, 0.5 to 10 ppm, and 1 to 20 ppm.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the NEXTTEQ NX-1000 PH3 detector tube used for?

The NEXTTEQ NX-1000 PH3 detector tube (NX204LM) is used to measure phosphine gas concentrations in industrial environments, such as fumigation monitoring or grain storage safety. It works with NEXTTEQ NX-1000 pumps and provides three measurement ranges: 0.25 to 5 ppm, 0.5 to 10 ppm, and 1 to 20 ppm.

What are the specifications of the NEXTTEQ NX204LM gas detection tube?

The NEXTTEQ NX204LM is a phosphine (PH3) gas detection tube supplied in a 10-pack. It offers three measurement ranges: 0.25 to 5 ppm, 0.5 to 10 ppm, and 1 to 20 ppm. It is designed for use with NEXTTEQ NX-1000 pumps. The manufacturer part number is NX204LM.

Where to buy NEXTTEQ NX204LM PH3 detector tubes worldwide?

3G Electric supplies NEXTTEQ NX204LM PH3 detector tubes worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this 10-pack of phosphine detection tubes for NEXTTEQ NX-1000 pumps.

How to use the NEXTTEQ NX-1000 PH3 detector tube with a pump?

To use the NEXTTEQ NX204LM tube, insert it into a NEXTTEQ NX-1000 pump, break both tips of the tube, and follow the pump’s stroke count for the desired range (0.25–5 ppm, 0.5–10 ppm, or 1–20 ppm). Read the stain length against the scale. Always refer to the manufacturer’s instructions for safe operation.

NEXTTEQ Products

3G Electric supplies NEXTTEQ gas detection tubes for use in nextteq nx-1000 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from NEXTTEQ

View all NEXTTEQ parts
Butadiene (C4H6) gas detection tube supplied in a 10-pack for use with NEXTTEQ NX-1000 pumps. Detects butadiene concentrations from 30 to 600 ppm in industrial environments such as petrochemical, rubber, and plastics manufacturing
NEXTTEQ
Butadiene (C4H6) gas detection tube supplied in a 10-pack for use with NEXTTEQ NX-1000 pumps. Detects butadiene concentrations from 30 to 600 ppm in industrial environments such as petrochemical, rubber, and plastics manufacturing
This gas detection tube is designed for use with NEXTTEQ NX-1000 pumps to measure phosphine (PH3) concentrations. It provides a detection range of 20 to 800 ppm and is supplied in a pack of 10 tubes. Typical applications include monitoring phosphine in industrial gas streams
NEXTTEQ
This gas detection tube is designed for use with NEXTTEQ NX-1000 pumps to measure phosphine (PH3) concentrations. It provides a detection range of 20 to 800 ppm and is supplied in a pack of 10 tubes. Typical applications include monitoring phosphine in industrial gas streams
Gas detection tube for use with NEXTTEQ NX-1000 pumps. Detects ethyl tert-butyl ether (C6H14O) in air over a range of 1 to 60 ppm. Supplied in a pack of 10. Suitable for industrial hygiene and safety air monitoring applications
NEXTTEQ
Gas detection tube for use with NEXTTEQ NX-1000 pumps. Detects ethyl tert-butyl ether (C6H14O) in air over a range of 1 to 60 ppm. Supplied in a pack of 10. Suitable for industrial hygiene and safety air monitoring applications
Gas detection tube for measuring dichloroethylene (C2H2Cl2) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Features break-off tip and four measurement ranges: 20 to 400 ppm, 4.2 to 84 ppm, 42 to 840 ppm, and 9.2 to 184 ppm. Suitable for industrial hygiene and environmental monitoring applications. Supplied as a 10-pack
NEXTTEQ
Gas detection tube for measuring dichloroethylene (C2H2Cl2) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Features break-off tip and four measurement ranges: 20 to 400 ppm, 4.2 to 84 ppm, 42 to 840 ppm, and 9.2 to 184 ppm. Suitable for industrial hygiene and environmental monitoring applications. Supplied as a 10-pack
Gas detection tube for measuring hexane (C6H14) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Provides two measurement ranges: 16 to 800 ppm and 4 to 200 ppm. Supplied in a 10-pack. Suitable for industrial hygiene, leak detection, and confined-space entry
NEXTTEQ
Gas detection tube for measuring hexane (C6H14) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Provides two measurement ranges: 16 to 800 ppm and 4 to 200 ppm. Supplied in a 10-pack. Suitable for industrial hygiene, leak detection, and confined-space entry
Ammonia (NH3) gas detection tube for use with NEXTTEQ NX-1000 pumps. Measures concentrations from 50 to 900 ppm. Supplied in a 10-pack. Suitable for industrial safety and environmental monitoring applications
NEXTTEQ
Ammonia (NH3) gas detection tube for use with NEXTTEQ NX-1000 pumps. Measures concentrations from 50 to 900 ppm. Supplied in a 10-pack. Suitable for industrial safety and environmental monitoring applications
Phosphine (PH3) gas detection tube for use with NEXTTEQ NX-1000 pumps. Measures PH3 concentrations in two ranges: 200 to 3,000 ppm and 400 to 6,000 ppm. Supplied in a pack of 10. Suitable for industrial environments where phosphine gas may be present
NEXTTEQ
Phosphine (PH3) gas detection tube for use with NEXTTEQ NX-1000 pumps. Measures PH3 concentrations in two ranges: 200 to 3,000 ppm and 400 to 6,000 ppm. Supplied in a pack of 10. Suitable for industrial environments where phosphine gas may be present
Carbon monoxide (CO) gas detection tube for use with NEXTTEQ NX-1000 pumps. Measures CO concentrations from 10 to 250 ppm. Pack of 10 single-use tubes for industrial gas analysis in combustion, HVAC, and process environments
NEXTTEQ
Carbon monoxide (CO) gas detection tube for use with NEXTTEQ NX-1000 pumps. Measures CO concentrations from 10 to 250 ppm. Pack of 10 single-use tubes for industrial gas analysis in combustion, HVAC, and process environments