The NEXTTEQ NX-1000 Detector Tube (MPN NX105) is a C2H2/C2H4 gas detection tube designed for use with NEXTTEQ NX-1000 pumps. This 5-pack includes break-off tips and detects acetylene and ethylene across two ranges…

SKU 3G-OTH-602171

Brand
NEXTTEQ
Item
Detector Tube: NEXTEQ NX-1000, C2H2/C2H4, Gas Detection Tube, With Pump
Category
Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

NEXTTEQ
Manufacturer Part Number
NX105
Type
C2H2/C2H4, Gas Detection Tube, With Pump, Break-Off Tip, 5 PK
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

NEXTTEQ Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The NEXTTEQ NX-1000 Detector Tube (MPN NX105) is a C2H2/C2H4 gas detection tube designed for use with NEXTTEQ NX-1000 pumps. This 5-pack includes break-off tips and detects acetylene and ethylene across two ranges: 20 to 300 ppm and 200 to 2,000 ppm.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the NEXTTEQ NX-1000 detector tube used for?

The NEXTTEQ NX-1000 detector tube (MPN NX105) is used to measure acetylene (C2H2) and ethylene (C2H4) concentrations in air. It is designed for use with NEXTTEQ NX-1000 pumps and covers two ranges: 20 to 300 ppm and 200 to 2,000 ppm.

What are the specifications of the NEXTTEQ NX-1000 detector tube?

The NEXTTEQ NX-1000 detector tube (MPN NX105) detects acetylene and ethylene. It has two measurement ranges: 20 to 300 ppm and 200 to 2,000 ppm. The tube features break-off tips and is sold in a 5-pack for use with NEXTTEQ NX-1000 pumps.

Where to buy NEXTTEQ NX-1000 detector tubes worldwide?

3G Electric supplies NEXTTEQ NX-1000 detector tubes (MPN NX105) worldwide. As a global industrial solutions provider, we handle logistics, customs, and delivery to your location. Contact us to order this 5-pack of C2H2/C2H4 gas detection tubes.

How to use the NEXTTEQ NX-1000 detector tube with a pump?

To use the NEXTTEQ NX-1000 detector tube, break off both tips, insert the tube into the NEXTTEQ NX-1000 pump, and draw the specified volume of air. Read the concentration directly from the tube's color change scale. Follow the pump manufacturer's instructions for accurate results.

NEXTTEQ Products

3G Electric supplies NEXTTEQ gas detection tubes for use in nextteq nx-1000 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from NEXTTEQ

View all NEXTTEQ parts
NEXTTEQ Detector Tube: NEXTEQ NX-1000, CH4S, Gas Detection Tube, Methyl Mercaptan ( CH4S ), 10 PK (MPN NX188H). Key specifications — attr914051: Methyl Mercaptan; attr914053: 50 to 1,000 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, CH4S, Gas Detection Tube, Methyl Mercaptan ( CH4S ), 10 PK (MPN NX188H). Key specifications — attr914051: Methyl Mercaptan; attr914053: 50 to 1,000 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, SO2, Gas Detection Tube, Sulfur Dioxide ( SO2 ), 10 PK (MPN NX211LM). Key specifications — attr914051: Sulfur Dioxide; attr914053: 20 to 300 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, SO2, Gas Detection Tube, Sulfur Dioxide ( SO2 ), 10 PK (MPN NX211LM). Key specifications — attr914051: Sulfur Dioxide; attr914053: 20 to 300 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C2H4O, Gas Detection Tube, Ethylene Oxide ( C2H4O ), 10 PK (MPN NX155H). Key specifications — attr914051: Ethylene Oxide; attr914053: 130 to 2600 ppm/50 to 1,000 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C2H4O, Gas Detection Tube, Ethylene Oxide ( C2H4O ), 10 PK (MPN NX155H). Key specifications — attr914051: Ethylene Oxide; attr914053: 130 to 2600 ppm/50 to 1,000 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C4H5Cl, Gas Detection Tube, Chloroprene ( C4H5Cl ), 5 PK (MPN NX127). Key specifications — attr914051: Chloroprene; attr914053: 0.5 to 10 ppm/1 to 20 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C4H5Cl, Gas Detection Tube, Chloroprene ( C4H5Cl ), 5 PK (MPN NX127). Key specifications — attr914051: Chloroprene; attr914053: 0.5 to 10 ppm/1 to 20 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, H2O, Gas Detection Tube, Water Vapor ( H2O ), 10 PK (MPN NX222M). Key specifications — attr914051: Water Vapor; attr914053: 1.7 to 33.8 mg/L.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, H2O, Gas Detection Tube, Water Vapor ( H2O ), 10 PK (MPN NX222M). Key specifications — attr914051: Water Vapor; attr914053: 1.7 to 33.8 mg/L.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, Cl3CNO2, Gas Detection Tube, Chloropicrin ( Cl3CNO2 ), 5 PK (MPN NX126). Key specifications — attr914051: Chloropicrin; attr914053: 0.05 to 8 ppm/0.1 to 16 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, Cl3CNO2, Gas Detection Tube, Chloropicrin ( Cl3CNO2 ), 5 PK (MPN NX126). Key specifications — attr914051: Chloropicrin; attr914053: 0.05 to 8 ppm/0.1 to 16 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C4H8Cl2O, Gas Detection Tube, With Pump, 2 to 30 ppm, 5 PK (MPN NX136). Key specifications — attr914051: Dichloroethyl Ether; attr914053: 2 to 30 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C4H8Cl2O, Gas Detection Tube, With Pump, 2 to 30 ppm, 5 PK (MPN NX136). Key specifications — attr914051: Dichloroethyl Ether; attr914053: 2 to 30 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C3H6O, Gas Detection Tube, Propylene Oxide ( C3H6O ), 5 PK (MPN NX208L). Key specifications — attr914051: Propylene Oxide; attr914053: 0.2 to 5 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C3H6O, Gas Detection Tube, Propylene Oxide ( C3H6O ), 5 PK (MPN NX208L). Key specifications — attr914051: Propylene Oxide; attr914053: 0.2 to 5 ppm.