We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

NEXTTEQ Detector Tube: NEXTEQ NX-1000, C6H12O2, Gas Detection Tube, Butyl Acetate ( C6H12O2 ) - Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
NEXTTEQGas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps

NEXTTEQ Detector Tube: NEXTEQ NX-1000, C6H12O2, Gas Detection Tube, Butyl Acetate ( C6H12O2 )

The NEXTTEQ NX-1000 Detector Tube (MPN NX116) is a gas detection tube for butyl acetate (C6H12O2), supplied in a 10-pack for use in NEXTTEQ NX-1000 pumps. It detects butyl acetate across a range of 10 to 400 ppm.

SKU 3G-OTH-602153

Brand
NEXTTEQ
Item
Detector Tube: NEXTEQ NX-1000, C6H12O2, Gas Detection Tube, Butyl Acetate
Category
Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

NEXTTEQ
Manufacturer Part Number
NX116
Type
C6H12O2, Gas Detection Tube, Butyl Acetate ( C6H12O2 ), 10 PK
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

NEXTTEQ Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The NEXTTEQ NX-1000 Detector Tube (MPN NX116) is a gas detection tube for butyl acetate (C6H12O2), supplied in a 10-pack for use in NEXTTEQ NX-1000 pumps. It detects butyl acetate across a range of 10 to 400 ppm.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the NEXTTEQ NX-1000 detector tube used for?

The NEXTTEQ NX-1000 detector tube (MPN NX116) is used to measure butyl acetate (C6H12O2) concentrations in air. It is designed for use with NEXTTEQ NX-1000 pumps and detects levels from 10 to 400 ppm, supporting industrial hygiene and safety monitoring.

What are the specifications of the NEXTTEQ NX-1000 butyl acetate tube?

The NEXTTEQ NX-1000 detector tube (MPN NX116) detects butyl acetate (C6H12O2) over a range of 10 to 400 ppm. It is supplied in a 10-pack and is intended for use with NEXTTEQ NX-1000 pumps. Each tube provides a single measurement.

Where to buy NEXTTEQ NX-1000 detector tubes worldwide?

3G Electric supplies NEXTTEQ NX-1000 detector tubes worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us to order the NX116 10-pack for butyl acetate detection.

How to use the NEXTTEQ NX-1000 detector tube for butyl acetate?

To use the NEXTTEQ NX-1000 detector tube (NX116), break off both tips, insert it into the NEXTTEQ NX-1000 pump, and draw the specified volume of air. Read the concentration directly from the stain length on the tube. Follow standard gas-detection best practices for accuracy.

NEXTTEQ Products

3G Electric supplies NEXTTEQ gas detection tubes for use in nextteq nx-1000 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from NEXTTEQ

View all NEXTTEQ parts
NEXTTEQ Detector Tube: NEXTEQ NX-1000, H2, Gas Detection Tube, Hydrogen ( H2 ), With Pump, 5 PK (MPN NX163). Key specifications — attr914051: Hydrogen; attr914053: 0.05 to 0.8% vol.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, H2, Gas Detection Tube, Hydrogen ( H2 ), With Pump, 5 PK (MPN NX163). Key specifications — attr914051: Hydrogen; attr914053: 0.05 to 0.8% vol.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C7H14O2, Gas Detection Tube, With Pump, 10 to 200 ppm, 10 PK (MPN NX201). Key specifications — attr914051: Pentyl Acetate; attr914053: 10 to 200 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C7H14O2, Gas Detection Tube, With Pump, 10 to 200 ppm, 10 PK (MPN NX201). Key specifications — attr914051: Pentyl Acetate; attr914053: 10 to 200 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, Cl2, Gas Detection Tube, Chlorine ( Cl2 ), With Pump, 10 PK (MPN NX122L). Key specifications — attr914051: Chlorine; attr914053: 0.05 to 1 ppm/0.1 to 2 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, Cl2, Gas Detection Tube, Chlorine ( Cl2 ), With Pump, 10 PK (MPN NX122L). Key specifications — attr914051: Chlorine; attr914053: 0.05 to 1 ppm/0.1 to 2 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C2H3Cl3, Gas Detection Tube, With Pump, Break-Off Tip, 5 PK (MPN NX181). Key specifications — attr914051: Methyl Chloroform; attr914053: 15 to 30 ppm/30 to 400 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C2H3Cl3, Gas Detection Tube, With Pump, Break-Off Tip, 5 PK (MPN NX181). Key specifications — attr914051: Methyl Chloroform; attr914053: 15 to 30 ppm/30 to 400 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, O2, Gas Detection Tube, Oxygen ( O2 ), With Pump, 5 PK (MPN NX198). Key specifications — attr914051: Oxygen; attr914053: 1.5 to 3% vol/3 to 24%.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, O2, Gas Detection Tube, Oxygen ( O2 ), With Pump, 5 PK (MPN NX198). Key specifications — attr914051: Oxygen; attr914053: 1.5 to 3% vol/3 to 24%.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, SO2, Gas Detection Tube, Sulfur Dioxide ( SO2 ), 10 PK (MPN NX211L). Key specifications — attr914051: Sulfur Dioxide; attr914053: 1 to 60 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, SO2, Gas Detection Tube, Sulfur Dioxide ( SO2 ), 10 PK (MPN NX211L). Key specifications — attr914051: Sulfur Dioxide; attr914053: 1 to 60 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C6H6, Gas Detection Tube, Benzene ( C6H6 ), With Pump, 5 PK (MPN NX111VH). Key specifications — attr914051: Benzene; attr914053: 5 to 300 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C6H6, Gas Detection Tube, Benzene ( C6H6 ), With Pump, 5 PK (MPN NX111VH). Key specifications — attr914051: Benzene; attr914053: 5 to 300 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C6H12O2, Gas Detection Tube, With Pump, 10 to 400 ppm, 10 PK (MPN NX171). Key specifications — attr914051: Isobutyl Acetate; attr914053: 10 to 400 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C6H12O2, Gas Detection Tube, With Pump, 10 to 400 ppm, 10 PK (MPN NX171). Key specifications — attr914051: Isobutyl Acetate; attr914053: 10 to 400 ppm.