We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

NEXTTEQ Detector Tube: NEXTEQ NX-1000, NH3, Gas Detection Tube, Ammonia ( NH3 ) - Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
NEXTTEQGas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps

NEXTTEQ Detector Tube: NEXTEQ NX-1000, NH3, Gas Detection Tube, Ammonia ( NH3 )

The NEXTTEQ NX-1000 Detector Tube (MPN NX108M) is an NH3 gas detection tube for ammonia, supplied in a 10-pack for use with NEXTTEQ NX-1000 pumps. It detects ammonia concentrations in two ranges: 10 to 260 ppm and 5…

SKU 3G-OTH-602057

Brand
NEXTTEQ
Item
Detector Tube: NEXTEQ NX-1000, NH3, Gas Detection Tube, Ammonia
Category
Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

NEXTTEQ
Manufacturer Part Number
NX108M
Type
NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

NEXTTEQ Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The NEXTTEQ NX-1000 Detector Tube (MPN NX108M) is an NH3 gas detection tube for ammonia, supplied in a 10-pack for use with NEXTTEQ NX-1000 pumps. It detects ammonia concentrations in two ranges: 10 to 260 ppm and 5 to 130 ppm.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the NEXTTEQ NX-1000 detector tube used for?

The NEXTTEQ NX-1000 detector tube (MPN NX108M) is used to measure ammonia (NH3) concentrations in air. It works with NEXTTEQ NX-1000 pumps and is suitable for industrial hygiene, leak detection, and environmental monitoring in chemical plants, refrigeration, and agriculture.

What are the specifications of the NEXTTEQ NX-1000 ammonia tube?

The NEXTTEQ NX-1000 tube (NX108M) detects ammonia (NH3) in two ranges: 10 to 260 ppm and 5 to 130 ppm. It is supplied as a 10-pack and requires a NEXTTEQ NX-1000 pump for operation. The tube is designed for spot-check measurements in industrial settings.

Where to buy NEXTTEQ NX-1000 detector tubes worldwide?

3G Electric supplies NEXTTEQ NX-1000 detector tubes worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this ammonia detection tube (NX108M).

How to use the NEXTTEQ NX-1000 ammonia detection tube?

To use the NEXTTEQ NX-1000 tube, break off both tips, insert it into the NEXTTEQ NX-1000 pump, and pull the handle to draw a sample. Follow the pump stroke count and read the stain length against the scale on the tube. Always refer to the manufacturer's instructions for accurate results.

NEXTTEQ Products

3G Electric supplies NEXTTEQ gas detection tubes for use in nextteq nx-1000 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from NEXTTEQ

View all NEXTTEQ parts
NEXTTEQ Detector Tube: NEXTEQ NX-1000, CH4S, Gas Detection Tube, Methyl Mercaptan ( CH4S ), 10 PK (MPN NX188L). Key specifications — attr914051: Methyl Mercaptan; attr914053: 0.5 to 5 ppm/1 to 10 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, CH4S, Gas Detection Tube, Methyl Mercaptan ( CH4S ), 10 PK (MPN NX188L). Key specifications — attr914051: Methyl Mercaptan; attr914053: 0.5 to 5 ppm/1 to 10 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, H2S, Gas Detection Tube, Hydrogen Sulfide ( H2S ), 10 PK (MPN NX169VH). Key specifications — attr914051: Hydrogen Sulfide; attr914053: 0.1 to 4% vol.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, H2S, Gas Detection Tube, Hydrogen Sulfide ( H2S ), 10 PK (MPN NX169VH). Key specifications — attr914051: Hydrogen Sulfide; attr914053: 0.1 to 4% vol.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, CH4S, Gas Detection Tube, Methyl Mercaptan ( CH4S ), 10 PK (MPN NX188H). Key specifications — attr914051: Methyl Mercaptan; attr914053: 50 to 1,000 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, CH4S, Gas Detection Tube, Methyl Mercaptan ( CH4S ), 10 PK (MPN NX188H). Key specifications — attr914051: Methyl Mercaptan; attr914053: 50 to 1,000 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, SO2, Gas Detection Tube, Sulfur Dioxide ( SO2 ), 10 PK (MPN NX211LM). Key specifications — attr914051: Sulfur Dioxide; attr914053: 20 to 300 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, SO2, Gas Detection Tube, Sulfur Dioxide ( SO2 ), 10 PK (MPN NX211LM). Key specifications — attr914051: Sulfur Dioxide; attr914053: 20 to 300 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C2H4O, Gas Detection Tube, Ethylene Oxide ( C2H4O ), 10 PK (MPN NX155H). Key specifications — attr914051: Ethylene Oxide; attr914053: 130 to 2600 ppm/50 to 1,000 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C2H4O, Gas Detection Tube, Ethylene Oxide ( C2H4O ), 10 PK (MPN NX155H). Key specifications — attr914051: Ethylene Oxide; attr914053: 130 to 2600 ppm/50 to 1,000 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C4H5Cl, Gas Detection Tube, Chloroprene ( C4H5Cl ), 5 PK (MPN NX127). Key specifications — attr914051: Chloroprene; attr914053: 0.5 to 10 ppm/1 to 20 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C4H5Cl, Gas Detection Tube, Chloroprene ( C4H5Cl ), 5 PK (MPN NX127). Key specifications — attr914051: Chloroprene; attr914053: 0.5 to 10 ppm/1 to 20 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, H2O, Gas Detection Tube, Water Vapor ( H2O ), 10 PK (MPN NX222M). Key specifications — attr914051: Water Vapor; attr914053: 1.7 to 33.8 mg/L.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, H2O, Gas Detection Tube, Water Vapor ( H2O ), 10 PK (MPN NX222M). Key specifications — attr914051: Water Vapor; attr914053: 1.7 to 33.8 mg/L.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, Cl3CNO2, Gas Detection Tube, Chloropicrin ( Cl3CNO2 ), 5 PK (MPN NX126). Key specifications — attr914051: Chloropicrin; attr914053: 0.05 to 8 ppm/0.1 to 16 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, Cl3CNO2, Gas Detection Tube, Chloropicrin ( Cl3CNO2 ), 5 PK (MPN NX126). Key specifications — attr914051: Chloropicrin; attr914053: 0.05 to 8 ppm/0.1 to 16 ppm.