We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

MADISON C4651-12802 Continuous Float Level Sensor - Continuous Float Liquid Level Sensors
MADISONContinuous Float Liquid Level Sensors

MADISON C4651-12802 Continuous Float Level Sensor

The MADISON Industrial Continuous Level Transmitter is a float level sensor designed for continuous level measurement of nonhazardous liquids. This rod-type probe features a 316 stainless steel body and stem, a…

SKU 3G-OTH-90280

Also listed as: C465112802 · C4651 12802

Brand
MADISON
Item
C4651-12802 Continuous Float Level Sensor
Category
Continuous Float Liquid Level Sensors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

MADISON
Manufacturer Part Number
C4651-12802
Type
+/-0.25 in
Accuracy
+/-0.25 in
Standards
CE
Probe Type
Rod
Product Type
Float Level Sensor
Body Material
316 Stainless Steel
Stem Material
316 Stainless Steel
Float Material
Polypropylene
For Media Type
Nonhazardous Liquids
Probe Material
316 Stainless Steel
Connection Type
NPT
Stainless Steel
316
Nameplate Voltage
12/30V DC
Mounting Direction
Vertical
Output Voltage Range
4 to 20mA

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

MADISON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The MADISON Industrial Continuous Level Transmitter is a float level sensor designed for continuous level measurement of nonhazardous liquids. This rod-type probe features a 316 stainless steel body and stem, a polypropylene float, and a 4 to 20mA output voltage range with a nameplate voltage of 12/30V DC. It offers an accuracy of +/-0.25 in, mounts vertically, and uses an NPT connection, complying with CE standards.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the MADISON C4651-12802 continuous level transmitter used for?

The MADISON C4651-12802 is a float level sensor used for continuous level measurement of nonhazardous liquids in industrial tanks and vessels. It provides a 4 to 20mA output signal proportional to liquid level, enabling remote monitoring and process control in water, wastewater, and chemical applications.

What are the specifications of the MADISON C4651-12802 float level sensor?

The MADISON C4651-12802 features a 316 stainless steel body and stem, a polypropylene float, and an accuracy of +/-0.25 in. It operates on 12/30V DC with a 4 to 20mA output, uses an NPT connection, mounts vertically, and complies with CE standards. It is designed for nonhazardous liquids only.

Where to buy the MADISON C4651-12802 level transmitter worldwide?

You can source the MADISON C4651-12802 continuous level transmitter through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time on this MADISON float level sensor.

How to install the MADISON C4651-12802 float level sensor?

Install the MADISON C4651-12802 vertically using the NPT connection into a tank nozzle or threaded port. Ensure the polypropylene float moves freely along the 316 stainless steel stem. Wire the 4 to 20mA output to a compatible controller or PLC. Follow standard industrial wiring practices and CE compliance guidelines.

Used in

Common applications for MADISON
Industrial tank level monitoring — MADISON M4400-ULL-NO vertically mounted float switch for high-level alarm in water storage tanks
Pump control in wastewater systems — MADISON M4168-1 side-mounted float switch for automatic pump start/stop in sump pits
Hydraulic system flow verification — MADISON FS8000-20003 piston flow switch for detecting flow in lubrication lines
Chemical processing level sensing — MADISON M3827-3NO stainless steel float switch for corrosive liquid level detection
Non-contact level measurement in bulk storage — MADISON U5098-D024-019 ultrasonic sensor for tank level monitoring up to 19 ft
Cooling water flow monitoring — MADISON FS8000-10010 compact flow switch for verifying coolant flow in heat exchangers
Not sure this is the right part? Photo-identify it

MADISON Products

3G Electric supplies MADISON continuous float liquid level sensors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Rod-type conductivity liquid level sensor for nonhazardous liquids. Features a 316 stainless steel stem and probe, 1 in NPT connection, and vertical mounting. Operates at 120V AC. Suitable for level detection in tanks, sumps, and process vessels
MADISON
Rod-type conductivity liquid level sensor for nonhazardous liquids. Features a 316 stainless steel stem and probe, 1 in NPT connection, and vertical mounting. Operates at 120V AC. Suitable for level detection in tanks, sumps, and process vessels
Vertically mounted float switch with selectable SPST stainless steel design. Electrical connection via lead wires. Requires minimum media specific gravity of 0.63. Used for liquid level detection and control in tanks, reservoirs, and process vessels
MADISON
Vertically mounted float switch with selectable SPST stainless steel design. Electrical connection via lead wires. Requires minimum media specific gravity of 0.63. Used for liquid level detection and control in tanks, reservoirs, and process vessels
Noncontact ultrasonic level sensor transmitter with 1 in NPT connection and PVC construction. Provides continuous level measurement with 4-20mA output, 30V DC supply, and accuracy of +/-0.25% of full scale over a 6 ft range. Suitable for liquid level sensing in tanks, sumps, and open channels where noncontact operation is required
MADISON
Noncontact ultrasonic level sensor transmitter with 1 in NPT connection and PVC construction. Provides continuous level measurement with 4-20mA output, 30V DC supply, and accuracy of +/-0.25% of full scale over a 6 ft range. Suitable for liquid level sensing in tanks, sumps, and open channels where noncontact operation is required
Noncontact ultrasonic level sensor transmitter with 1 in NPT connection and 1 in antenna diameter. Measures liquid level in tanks or vessels up to 6 ft with ±0.25% accuracy. Operates on 30V DC with 4-20mA output. PVC construction suitable for water, wastewater, and industrial fluid management
MADISON
Noncontact ultrasonic level sensor transmitter with 1 in NPT connection and 1 in antenna diameter. Measures liquid level in tanks or vessels up to 6 ft with ±0.25% accuracy. Operates on 30V DC with 4-20mA output. PVC construction suitable for water, wastewater, and industrial fluid management
Noncontact ultrasonic level sensor transmitter with 1 in NPT connection and 1 in antenna diameter. Measures liquid levels up to 6 ft with +/-0.25% accuracy. Operates on 30V DC with 4-20mA output. PVC construction. Suitable for continuous level monitoring in tanks or vessels
MADISON
Noncontact ultrasonic level sensor transmitter with 1 in NPT connection and 1 in antenna diameter. Measures liquid levels up to 6 ft with +/-0.25% accuracy. Operates on 30V DC with 4-20mA output. PVC construction. Suitable for continuous level monitoring in tanks or vessels
Vertically mounted float switch with 316 stainless steel construction. Features selectable SPST contact and lead wire electrical connection. Requires minimum media specific gravity of 0.69 for operation. Used for liquid level detection in tanks or vessels
MADISON
Vertically mounted float switch with 316 stainless steel construction. Features selectable SPST contact and lead wire electrical connection. Requires minimum media specific gravity of 0.69 for operation. Used for liquid level detection in tanks or vessels

More from MADISON

View all MADISON parts
Rod-type float level sensor with 316 stainless steel construction for body, stem, float, and probe. Accuracy ±0.25 in, 4 to 20mA output, 12/30V DC supply. NPT connection, vertical mounting, cULus listed for nonhazardous liquids. Used for continuous level measurement in industrial tanks and vessels
MADISON
Rod-type float level sensor with 316 stainless steel construction for body, stem, float, and probe. Accuracy ±0.25 in, 4 to 20mA output, 12/30V DC supply. NPT connection, vertical mounting, cULus listed for nonhazardous liquids. Used for continuous level measurement in industrial tanks and vessels
Rod-type float level sensor with 316 stainless steel body and stem, Buna N float, and 4 to 20mA output. Accuracy +/-0.25 in, operates on 12/30V DC, vertical NPT connection. cULus listed for chemical media. Used for continuous level monitoring in tanks and process vessels
MADISON
Rod-type float level sensor with 316 stainless steel body and stem, Buna N float, and 4 to 20mA output. Accuracy +/-0.25 in, operates on 12/30V DC, vertical NPT connection. cULus listed for chemical media. Used for continuous level monitoring in tanks and process vessels