We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

LINCOLN ELECTRIC Contact Tip: Magnum 400A, 3/64 in - Magnum 400A Contact Tips
LINCOLN ELECTRICMagnum 400A Contact Tips

LINCOLN ELECTRIC Contact Tip: Magnum 400A, 3/64 in

The LINCOLN ELECTRIC Magnum 400A Contact Tip (MPN KP14A-364) is a standard-duty, threaded contact tip designed for use with the Magnum Pro 550A nozzle series. It accommodates a maximum wire diameter of 3/64 in.

SKU 3G-OTH-357124

Brand
LINCOLN ELECTRIC
Item
Contact Tip: Magnum 400A, 3/64 in
Category
Magnum 400A Contact Tips
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

LINCOLN ELECTRIC
Manufacturer Part Number
KP14A-364
Duty Rating
Standard Duty
Connection Type
Threaded
For Nozzle Series
Magnum Pro 550A
Maximum Wire Diameter (Merch)
3/64 in
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

LINCOLN ELECTRIC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The LINCOLN ELECTRIC Magnum 400A Contact Tip (MPN KP14A-364) is a standard-duty, threaded contact tip designed for use with the Magnum Pro 550A nozzle series. It accommodates a maximum wire diameter of 3/64 in.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the LINCOLN ELECTRIC Magnum 400A contact tip used for?

The LINCOLN ELECTRIC Magnum 400A contact tip (MPN KP14A-364) is used in MIG welding to transfer electrical current to the wire electrode. It is designed for standard-duty applications with the Magnum Pro 550A nozzle series and accommodates a maximum wire diameter of 3/64 in.

What are the specifications of the LINCOLN ELECTRIC Magnum 400A contact tip?

The LINCOLN ELECTRIC Magnum 400A contact tip has a standard duty rating, threaded connection type, and is designed for the Magnum Pro 550A nozzle series. It supports a maximum wire diameter of 3/64 in. The manufacturer part number is KP14A-364.

Where to buy LINCOLN ELECTRIC Magnum 400A contact tips worldwide?

3G Electric supplies LINCOLN ELECTRIC Magnum 400A contact tips worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time on the KP14A-364 contact tip.

How to select the correct LINCOLN ELECTRIC contact tip for a Magnum Pro 550A nozzle?

To select the correct LINCOLN ELECTRIC contact tip for a Magnum Pro 550A nozzle, ensure the tip has a threaded connection and matches the wire diameter you are using. The Magnum 400A tip (KP14A-364) is a standard-duty option for 3/64 in wire. Always verify compatibility with your welding gun.

Used in

Common applications for LINCOLN ELECTRIC
General steel fabrication — Lincoln Electric UltraCore HD-12C flux-cored wire (E71T-12C, 0.052 in) for single- or multiple-pass welding on carbon steel.
All-position welding with AC power — Lincoln Electric Fleetweld 180 stick electrode (E6011, 5/32 in) for repair and maintenance on galvanized or painted steel.
Severe abrasion resistance — Lincoln Electric Wearshield ME hardfacing electrode (1/8 in, 55 HRC) for earthmoving equipment and crusher components.
Multiprocess welding — Lincoln Electric Flextec 500X with LF-74 wire feeder for switching between MIG, stick, and TIG processes in fabrication shops.
TIG welding with improved gas coverage — Lincoln Electric gas lens (45V44, 3/32 in max electrode) for precision welding of stainless steel or aluminum.
MIG welding of carbon steel — Lincoln Electric ER70S-3 wire (0.035 in, 60 lb spool) for general fabrication and structural welding.

LINCOLN ELECTRIC Products

3G Electric supplies LINCOLN ELECTRIC magnum 400a contact tips. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
LINCOLN ELECTRIC Contact Tip: Magnum Pro 350A, 3/64 in, Std Duty, Lincoln (MPN KP2744-364A5356). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 350A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 3/64 in.
LINCOLN ELECTRIC
LINCOLN ELECTRIC Contact Tip: Magnum Pro 350A, 3/64 in, Std Duty, Lincoln (MPN KP2744-364A5356). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 350A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 3/64 in.
LINCOLN ELECTRIC Contact Tip: Magnum Pro 350A, 1/16 in, Std Duty, Lincoln (MPN KP2744-116A). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 350A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 1/16 in.
LINCOLN ELECTRIC
LINCOLN ELECTRIC Contact Tip: Magnum Pro 350A, 1/16 in, Std Duty, Lincoln (MPN KP2744-116A). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 350A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 1/16 in.
LINCOLN ELECTRIC Contact Tip: Magnum 100A, 0.035 in, Std Duty, Lincoln (MPN KP2078-1B1). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum 100A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 0.035 in.
LINCOLN ELECTRIC
LINCOLN ELECTRIC Contact Tip: Magnum 100A, 0.035 in, Std Duty, Lincoln (MPN KP2078-1B1). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum 100A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 0.035 in.
LINCOLN ELECTRIC Contact Tip: Magnum Pro 350A, 0.035 in, Std Duty, Lincoln (MPN KP2744-035A). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 350A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 0.035 in.
LINCOLN ELECTRIC
LINCOLN ELECTRIC Contact Tip: Magnum Pro 350A, 0.035 in, Std Duty, Lincoln (MPN KP2744-035A). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 350A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 0.035 in.
LINCOLN ELECTRIC Contact Tip: Magnum Pro 550A, 7/64 in, Std Duty (MPN KP2745-764). Key specifications — attr30080: Standard Duty; attr30077: Threaded; attr30082: Magnum Pro 550A; attr30067: LINCOLN ELECTRIC; attr30081: Magnum Pro 550; attr59180: 7/64 in.
LINCOLN ELECTRIC
LINCOLN ELECTRIC Contact Tip: Magnum Pro 550A, 7/64 in, Std Duty (MPN KP2745-764). Key specifications — attr30080: Standard Duty; attr30077: Threaded; attr30082: Magnum Pro 550A; attr30067: LINCOLN ELECTRIC; attr30081: Magnum Pro 550; attr59180: 7/64 in.
LINCOLN ELECTRIC Contact Tip: Magnum Pro 550A, 3/32 in, Std Duty (MPN KP2745-332). Key specifications — attr30080: Standard Duty; attr30077: Threaded; attr30082: Magnum Pro 550A; attr30067: LINCOLN ELECTRIC; attr30081: Magnum Pro 550; attr59180: 3/32 in.
LINCOLN ELECTRIC
LINCOLN ELECTRIC Contact Tip: Magnum Pro 550A, 3/32 in, Std Duty (MPN KP2745-332). Key specifications — attr30080: Standard Duty; attr30077: Threaded; attr30082: Magnum Pro 550A; attr30067: LINCOLN ELECTRIC; attr30081: Magnum Pro 550; attr59180: 3/32 in.

More from LINCOLN ELECTRIC

View all LINCOLN ELECTRIC parts
LINCOLN ELECTRIC Contact Tip: Magnum 400A, 0.025 in, Std Duty (MPN KP14-25). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 550A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 0.025 in.
LINCOLN ELECTRIC
LINCOLN ELECTRIC Contact Tip: Magnum 400A, 0.025 in, Std Duty (MPN KP14-25). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 550A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 0.025 in.
LINCOLN ELECTRIC Contact Tip: Magnum 400A, 0.03 in, Std Duty (MPN KP14-30). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 550A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 0.03 in.
LINCOLN ELECTRIC
LINCOLN ELECTRIC Contact Tip: Magnum 400A, 0.03 in, Std Duty (MPN KP14-30). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 550A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 0.03 in.
LINCOLN ELECTRIC Contact Tip: Magnum 400A, 0.035 in, Std Duty (MPN KP14-35-B100). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 550A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 0.035 in.
LINCOLN ELECTRIC
LINCOLN ELECTRIC Contact Tip: Magnum 400A, 0.035 in, Std Duty (MPN KP14-35-B100). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 550A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 0.035 in.
LINCOLN ELECTRIC Contact Tip: Magnum 400A, 0.035 in, Std Duty, Lincoln (MPN KP14-35). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 550A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 0.035 in.
LINCOLN ELECTRIC
LINCOLN ELECTRIC Contact Tip: Magnum 400A, 0.035 in, Std Duty, Lincoln (MPN KP14-35). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 550A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 0.035 in.
LINCOLN ELECTRIC Contact Tip: Magnum 400A, 0.04 in, Std Duty (MPN KP14-40). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 550A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 0.04 in.
LINCOLN ELECTRIC
LINCOLN ELECTRIC Contact Tip: Magnum 400A, 0.04 in, Std Duty (MPN KP14-40). Key specifications — Duty Rating: Standard Duty; Connection Type: Threaded; For Nozzle Series: Magnum Pro 550A; Brand: LINCOLN ELECTRIC; Maximum Wire Diameter (Merch): 0.04 in.