We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

KUNKLE VALVE Safety Relief Valve: MNPT x FNPT, 3/4 in x 1 in, 264 psi Max. Op Pressure - ASME Section I Steam Pressure Relief Valves
KUNKLE VALVEASME Section I Steam Pressure Relief Valves

KUNKLE VALVE Safety Relief Valve: MNPT x FNPT, 3/4 in x 1 in, 264 psi Max. Op Pressure

The KUNKLE VALVE Safety Relief Valve is an ASME Section I steam pressure relief valve with a 3/4 in MNPT x 1 in FNPT connection, constructed in bronze. It has a maximum operating pressure of 264 psi (MPN…

SKU 3G-OTH-446034

Brand
KUNKLE VALVE
Item
Safety Relief Valve: MNPT x FNPT, 3/4 in x 1 in, 264 psi Max. Op Pressure
Category
ASME Section I Steam Pressure Relief Valves
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

KUNKLE VALVE
Manufacturer Part Number
6010EDE01AAM0050
Type
3/4 in x 1 in, Bronze
Max. Op Pressure
264 psi

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

KUNKLE VALVE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KUNKLE VALVE Safety Relief Valve is an ASME Section I steam pressure relief valve with a 3/4 in MNPT x 1 in FNPT connection, constructed in bronze. It has a maximum operating pressure of 264 psi (MPN 6010EDE01AAM0050).

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is a KUNKLE VALVE safety relief valve used for?

This KUNKLE VALVE safety relief valve is used for overpressure protection on steam boilers and pressure vessels. It meets ASME Section I requirements for steam service, automatically relieving excess pressure to prevent catastrophic failure in industrial heating and process systems.

What are the specifications of the KUNKLE VALVE 6010EDE01AAM0050?

The KUNKLE VALVE 6010EDE01AAM0050 is a 3/4 in x 1 in MNPT x FNPT safety relief valve with a maximum operating pressure of 264 psi. It is constructed from bronze and is designed for ASME Section I steam pressure relief applications.

Where to buy KUNKLE VALVE safety relief valves worldwide?

3G Electric supplies KUNKLE VALVE safety relief valves worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us to source the 6010EDE01AAM0050 or other KUNKLE VALVE models for your application.

How to select the correct KUNKLE VALVE safety relief valve?

Select a KUNKLE VALVE safety relief valve based on your system's maximum allowable working pressure, required relieving capacity, and fluid service (steam, air, or liquid). Verify connection size and material compatibility—bronze for non-corrosive media. Always consult ASME Section I for steam applications to ensure proper sizing and set pressure.

Used in

Common applications for KUNKLE VALVE
Steam boiler overpressure protection — ASME Section I safety relief valves (e.g., 6010EDM01AAM0200)
Compressed air system pressure relief — Non-code adjustable relief valves (e.g., 0019-D12-MG0225)
Inert gas storage tank protection — ASME Section VIII valves (e.g., 6010GFM01AKM0100)
Hydraulic liquid system overpressure — Non-code adjustable relief valves (e.g., 0019-C12-MG0225)
Industrial process piping safety — ASME Section XIII valves (e.g., 6010GFM01AKM0100)
Low-temperature gas handling — Non-code adjustable relief valves rated to -60°F (e.g., 0019-G12-MG0225)

KUNKLE VALVE Products

3G Electric supplies KUNKLE VALVE asme section i steam pressure relief valves. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This ASME Section I steam pressure relief valve features a bronze body with 3/4 in MNPT inlet and 1 in FNPT outlet. Rated for a maximum operating pressure of 264 psi, it provides overpressure protection for steam boilers and pressure vessels
KUNKLE VALVE
This ASME Section I steam pressure relief valve features a bronze body with 3/4 in MNPT inlet and 1 in FNPT outlet. Rated for a maximum operating pressure of 264 psi, it provides overpressure protection for steam boilers and pressure vessels
This ASME Section I steam pressure relief valve features a bronze body with 3/4 in MNPT inlet and 1 in FNPT outlet. Rated for a maximum operating pressure of 264 psi, it is used to protect boilers and pressure vessels from overpressure in steam systems
KUNKLE VALVE
This ASME Section I steam pressure relief valve features a bronze body with 3/4 in MNPT inlet and 1 in FNPT outlet. Rated for a maximum operating pressure of 264 psi, it is used to protect boilers and pressure vessels from overpressure in steam systems
This ASME Section I steam pressure relief valve features a bronze body with 3/4 in male NPT inlet and 1 in female NPT outlet. It has a maximum operating pressure of 264 psi. Used for overpressure protection on steam boilers and pressure vessels in industrial boiler systems, power plants, and process heating equipment
KUNKLE VALVE
This ASME Section I steam pressure relief valve features a bronze body with 3/4 in male NPT inlet and 1 in female NPT outlet. It has a maximum operating pressure of 264 psi. Used for overpressure protection on steam boilers and pressure vessels in industrial boiler systems, power plants, and process heating equipment
This ASME Section I steam pressure relief valve features a bronze body with 1/2 in male NPT inlet and 3/4 in female NPT outlet. It is rated for a maximum operating pressure of 264 psi. Typical applications include overpressure protection for steam boilers and pressure vessels in industrial steam systems
KUNKLE VALVE
This ASME Section I steam pressure relief valve features a bronze body with 1/2 in male NPT inlet and 3/4 in female NPT outlet. It is rated for a maximum operating pressure of 264 psi. Typical applications include overpressure protection for steam boilers and pressure vessels in industrial steam systems
Bronze safety relief valve with 1/2 in MNPT inlet and 3/4 in FNPT outlet. Rated for maximum operating pressure of 264 psi. Designed for overpressure protection on ASME Section I steam boilers and pressure vessels
KUNKLE VALVE
Bronze safety relief valve with 1/2 in MNPT inlet and 3/4 in FNPT outlet. Rated for maximum operating pressure of 264 psi. Designed for overpressure protection on ASME Section I steam boilers and pressure vessels
This ASME Section I steam pressure relief valve features a bronze body with 1/2 in MNPT inlet and 3/4 in FNPT outlet. Rated for a maximum operating pressure of 264 psi, it is used for overpressure protection on steam boilers and pressure vessels
KUNKLE VALVE
This ASME Section I steam pressure relief valve features a bronze body with 1/2 in MNPT inlet and 3/4 in FNPT outlet. Rated for a maximum operating pressure of 264 psi, it is used for overpressure protection on steam boilers and pressure vessels

More from KUNKLE VALVE

View all KUNKLE VALVE parts
This ASME Section I steam pressure relief valve features a bronze body with 1 1/4 in MNPT inlet and 1 1/2 in FNPT outlet. Rated for a maximum operating pressure of 264 psi, it provides overpressure protection for steam boilers and pressure vessels in industrial steam systems
KUNKLE VALVE
This ASME Section I steam pressure relief valve features a bronze body with 1 1/4 in MNPT inlet and 1 1/2 in FNPT outlet. Rated for a maximum operating pressure of 264 psi, it provides overpressure protection for steam boilers and pressure vessels in industrial steam systems
ASME Section I steam pressure relief valve with 1 in MNPT inlet and 1 1/4 in FNPT outlet. Constructed of bronze with a maximum operating pressure of 264 psi. Used for overpressure protection on steam boilers and pressure vessels
KUNKLE VALVE
ASME Section I steam pressure relief valve with 1 in MNPT inlet and 1 1/4 in FNPT outlet. Constructed of bronze with a maximum operating pressure of 264 psi. Used for overpressure protection on steam boilers and pressure vessels
This ASME Section I steam pressure relief valve features a bronze body with 2 in MNPT inlet and 2 1/2 in FNPT outlet. Rated for a maximum operating pressure of 264 psi, it automatically opens to release excess steam and reseats to protect boilers and pressure vessels from overpressure
KUNKLE VALVE
This ASME Section I steam pressure relief valve features a bronze body with 2 in MNPT inlet and 2 1/2 in FNPT outlet. Rated for a maximum operating pressure of 264 psi, it automatically opens to release excess steam and reseats to protect boilers and pressure vessels from overpressure
This ASME Section I steam pressure relief valve features a bronze body with 1 1/4 in MNPT inlet and 1 1/2 in FNPT outlet. It is rated for a maximum operating pressure of 264 psi. Used to protect steam boilers and pressure vessels from overpressure conditions
KUNKLE VALVE
This ASME Section I steam pressure relief valve features a bronze body with 1 1/4 in MNPT inlet and 1 1/2 in FNPT outlet. It is rated for a maximum operating pressure of 264 psi. Used to protect steam boilers and pressure vessels from overpressure conditions
This ASME Section I steam pressure relief valve is constructed with a bronze body and features a 1/2 in MNPT inlet and 3/4 in FNPT outlet. It has a maximum operating pressure of 264 psi and is designed for overpressure protection on steam boilers and pressure vessels in industrial heating and power generation systems
KUNKLE VALVE
This ASME Section I steam pressure relief valve is constructed with a bronze body and features a 1/2 in MNPT inlet and 3/4 in FNPT outlet. It has a maximum operating pressure of 264 psi and is designed for overpressure protection on steam boilers and pressure vessels in industrial heating and power generation systems
This ASME Section I steam pressure relief valve features a bronze body with 1 1/4 in MNPT x 1 1/2 in FNPT connections. It has a maximum operating pressure of 264 psi and is designed to protect boilers and pressure vessels from overpressure by automatically releasing steam
KUNKLE VALVE
This ASME Section I steam pressure relief valve features a bronze body with 1 1/4 in MNPT x 1 1/2 in FNPT connections. It has a maximum operating pressure of 264 psi and is designed to protect boilers and pressure vessels from overpressure by automatically releasing steam
ASME Section I steam pressure relief valve with bronze body, 2 in MNPT x 2 1/2 in FNPT connections, and maximum operating pressure of 264 psi. Used for overpressure protection on steam boilers and pressure vessels
KUNKLE VALVE
ASME Section I steam pressure relief valve with bronze body, 2 in MNPT x 2 1/2 in FNPT connections, and maximum operating pressure of 264 psi. Used for overpressure protection on steam boilers and pressure vessels
ASME Section I steam pressure relief valve with 2 in male NPT inlet and 2 1/2 in female NPT outlet. Bronze body construction. Maximum operating pressure 264 psi. Automatically opens at set pressure to protect steam boilers and pressure vessels from overpressure
KUNKLE VALVE
ASME Section I steam pressure relief valve with 2 in male NPT inlet and 2 1/2 in female NPT outlet. Bronze body construction. Maximum operating pressure 264 psi. Automatically opens at set pressure to protect steam boilers and pressure vessels from overpressure