We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

KDR LINE REACTORS Input Line Reactor: Open, Low Z, 500 hp Max Output Power, 480V AC - Input Line Reactors
KDR LINE REACTORSInput Line Reactors

KDR LINE REACTORS Input Line Reactor: Open, Low Z, 500 hp Max Output Power, 480V AC

The KDR LINE REACTORS Input Line Reactor: Open (SKU 3G-OTH-622495, MPN KDRULL2L) is a Low Z, 610 A Output Current - Max reactor designed for 480V AC systems with 500 hp Max Output Power. 3G Electric interprets this…

SKU 3G-OTH-622495

Brand
KDR LINE REACTORS
Item
Input Line Reactor: Open, Low Z, 500 hp Max Output Power, 480V AC
Category
Input Line Reactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

KDR LINE REACTORS
Manufacturer Part Number
KDRULL2L
Type
Low Z, 610 A Output Current - Max
AC
480V
Max Output Power
500 hp

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

KDR LINE REACTORS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KDR LINE REACTORS Input Line Reactor: Open (SKU 3G-OTH-622495, MPN KDRULL2L) is a Low Z, 610 A Output Current - Max reactor designed for 480V AC systems with 500 hp Max Output Power. 3G Electric interprets this demand and delivers this KDR component across 14 industrial departments, with specialist depth in combustion, pumps and controls as an authorised distributor.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is a KDR input line reactor used for?

A KDR input line reactor protects variable frequency drives and other power electronics from harmonic distortion, voltage spikes, and current surges. It is commonly used in industrial motor control systems, pumps, and HVAC equipment to improve power quality and extend equipment life.

What are the specifications of the KDRULL2L input line reactor?

The KDRULL2L is a Low Z, open-style input line reactor rated for 480V AC systems with a maximum output current of 610 A and a maximum output power of 500 hp. It is designed for demanding industrial applications requiring reliable harmonic mitigation and surge protection.

Where to buy KDR line reactors worldwide?

3G Electric supplies the KDRULL2L input line reactor to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. As a global industrial solutions provider, we source and deliver genuine KDR components across 14 departments, including specialist expertise in pumps and controls.

How to select the right input line reactor for a 480V AC system?

Select an input line reactor by matching its voltage rating (e.g., 480V AC) and current rating (e.g., 610 A) to your drive's full-load amps. Consider the reactor's impedance (Low Z for minimal voltage drop) and maximum output power (e.g., 500 hp). Consult the drive manufacturer's guidelines for optimal harmonic filtering.

KDR LINE REACTORS Products

3G Electric supplies KDR LINE REACTORS input line reactors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from KDR LINE REACTORS

View all KDR LINE REACTORS parts
Input Line Reactor: Open, Low Z, 600 hp Max Output Power, 575/600V AC, 610 A Output Current - Max (MPN KDRULL42L)
KDR LINE REACTORS
Input Line Reactor: Open, Low Z, 600 hp Max Output Power, 575/600V AC, 610 A Output Current - Max (MPN KDRULL42L)
Input Line Reactor: Open, Low Z, 100 hp Max Output Power, 575/600V AC, 99 A Output Current - Max (MPN KDRULF45L)
KDR LINE REACTORS
Input Line Reactor: Open, Low Z, 100 hp Max Output Power, 575/600V AC, 99 A Output Current - Max (MPN KDRULF45L)
Input Line Reactor: UL Type 1, High Z, 60 hp Max Output Power, 575/600V AC, 205 W Watts Loss (MPN KDRH43HE01)
KDR LINE REACTORS
Input Line Reactor: UL Type 1, High Z, 60 hp Max Output Power, 575/600V AC, 205 W Watts Loss (MPN KDRH43HE01)
Input Line Reactor: Open, Low Z, 500 hp Max Output Power, 575/600V AC, 480 A Output Current - Max (MPN KDRULL45L)
KDR LINE REACTORS
Input Line Reactor: Open, Low Z, 500 hp Max Output Power, 575/600V AC, 480 A Output Current - Max (MPN KDRULL45L)
Input Line Reactor: UL Type 1, Low Z, 1.5 hp Max Output Power, 208/240V AC, 8 A Output Current - Max (MPN KDRMA25L1E01)
KDR LINE REACTORS
Input Line Reactor: UL Type 1, Low Z, 1.5 hp Max Output Power, 208/240V AC, 8 A Output Current - Max (MPN KDRMA25L1E01)
Input Line Reactor: Open, Low Z, 15 hp Max Output Power, 460/480V AC, 30 A Output Current - Max (MPN KDRULB2L)
KDR LINE REACTORS
Input Line Reactor: Open, Low Z, 15 hp Max Output Power, 460/480V AC, 30 A Output Current - Max (MPN KDRULB2L)
Input Line Reactor: Open, Low Z, 350 hp Max Output Power, 460/480V AC, 500 A Output Current - Max (MPN KDRULJ2L)
KDR LINE REACTORS
Input Line Reactor: Open, Low Z, 350 hp Max Output Power, 460/480V AC, 500 A Output Current - Max (MPN KDRULJ2L)
Input Line Reactor: Open, High Z, 20 hp Max Output Power, 575/600V AC, 23 A Output Current - Max (MPN KDRD41H)
KDR LINE REACTORS
Input Line Reactor: Open, High Z, 20 hp Max Output Power, 575/600V AC, 23 A Output Current - Max (MPN KDRD41H)