KDR LINE REACTORS Input Line Reactor: Open, Low Z, 125 hp Max Output Power, 208/240V AC - Input Line Reactors
KDR LINE REACTORSInput Line Reactors

KDR LINE REACTORS Input Line Reactor: Open, Low Z, 125 hp Max Output Power, 208/240V AC

The KDR LINE REACTORS Input Line Reactor: Open (SKU KDRULG22L, MPN KDRULG22L) is a Low Z, 377 A Output Current - Max unit rated for 125 hp Max Output Power at 208/240V AC. 3G Electric interprets your demand for this…

SKU 3G-OTH-622469

Brand
KDR LINE REACTORS
Item
Input Line Reactor: Open, Low Z, 125 hp Max Output Power, 208/240V AC
Category
Input Line Reactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

KDR LINE REACTORS
Manufacturer Part Number
KDRULG22L
Type
Low Z, 377 A Output Current - Max
AC
208/240V
Max Output Power
125 hp

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

KDR LINE REACTORS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KDR LINE REACTORS Input Line Reactor: Open (SKU KDRULG22L, MPN KDRULG22L) is a Low Z, 377 A Output Current - Max unit rated for 125 hp Max Output Power at 208/240V AC. 3G Electric interprets your demand for this OEM-specified component and delivers it with specialist support across 14 industrial departments, including deep expertise in controls and power transmission.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is a KDR line reactor used for?

A KDR line reactor protects variable frequency drives and other power electronics from harmonics, voltage spikes, and current distortion. It smooths incoming power, reduces electrical noise, and extends equipment life in industrial motor control and power transmission systems.

What are the specifications of the KDRULG22L input line reactor?

The KDRULG22L is an open-style, low-impedance input line reactor rated for 125 hp max output power at 208/240V AC, with 377 A max output current. It is designed for industrial applications requiring robust harmonic mitigation and surge protection.

Where to buy KDR line reactors worldwide?

3G Electric supplies the KDRULG22L and other KDR line reactors worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for a quote and lead time on this OEM-specified component.

How to select the right input line reactor for a VFD?

Select a line reactor by matching its voltage and current ratings to your VFD and motor. The KDRULG22L is a low-impedance unit for 208/240V AC systems up to 125 hp. Always verify the reactor's impedance percentage and ambient temperature rating per the drive manufacturer's guidelines.

KDR LINE REACTORS Products

3G Electric supplies KDR LINE REACTORS input line reactors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Input Line Reactor: UL Type 1, Low Z, 2 hp Max Output Power, 575/600V AC, 3.2 A Output Current - Max (MPN KDRMA47L1E01)
KDR LINE REACTORS
Input Line Reactor: UL Type 1, Low Z, 2 hp Max Output Power, 575/600V AC, 3.2 A Output Current - Max (MPN KDRMA47L1E01)
Input Line Reactor: UL Type 1, High Z, 50 hp Max Output Power, 575/600V AC, 165 W Watts Loss (MPN KDRF45HE01)
KDR LINE REACTORS
Input Line Reactor: UL Type 1, High Z, 50 hp Max Output Power, 575/600V AC, 165 W Watts Loss (MPN KDRF45HE01)
Input Line Reactor: UL Type 1, Low Z, 0.75 hp Max Output Power, 575/600V AC, 10.9 W Watts Loss (MPN KDRMA44L1E01)
KDR LINE REACTORS
Input Line Reactor: UL Type 1, Low Z, 0.75 hp Max Output Power, 575/600V AC, 10.9 W Watts Loss (MPN KDRMA44L1E01)
Output Line Reactor: UL Type 1, Ultra Low Z, 75 hp Max Output Power, 575/600V AC, 187.5 W Watts Loss (MPN KDRULF32PE01)
KDR LINE REACTORS
Output Line Reactor: UL Type 1, Ultra Low Z, 75 hp Max Output Power, 575/600V AC, 187.5 W Watts Loss (MPN KDRULF32PE01)

More from KDR LINE REACTORS

View all KDR LINE REACTORS parts
Input Line Reactor: Open, Low Z, 60 hp Max Output Power, 460/480V AC, 77 A Output Current - Max (MPN KDRF4L)
KDR LINE REACTORS
Input Line Reactor: Open, Low Z, 60 hp Max Output Power, 460/480V AC, 77 A Output Current - Max (MPN KDRF4L)
Input Line Reactor: Open, High Z, 50 hp Max Output Power, 208/240V AC, 143 A Output Current - Max (MPN KDRULH24H)
KDR LINE REACTORS
Input Line Reactor: Open, High Z, 50 hp Max Output Power, 208/240V AC, 143 A Output Current - Max (MPN KDRULH24H)
Input Line Reactor: Open, Low Z, 3 hp Max Output Power, 208/240V AC, 12 A Output Current - Max (MPN KDRAA28L2)
KDR LINE REACTORS
Input Line Reactor: Open, Low Z, 3 hp Max Output Power, 208/240V AC, 12 A Output Current - Max (MPN KDRAA28L2)
Input Line Reactor: Open, Low Z, 1.5 hp Max Output Power, 460/480V AC, 3.4 A Output Current - Max (MPN KDRMA6L1)
KDR LINE REACTORS
Input Line Reactor: Open, Low Z, 1.5 hp Max Output Power, 460/480V AC, 3.4 A Output Current - Max (MPN KDRMA6L1)
Input Line Reactor: Open, Low Z, 2 hp Max Output Power, 208/240V AC, 10 A Output Current - Max (MPN KDRMA27L1)
KDR LINE REACTORS
Input Line Reactor: Open, Low Z, 2 hp Max Output Power, 208/240V AC, 10 A Output Current - Max (MPN KDRMA27L1)
Input Line Reactor: Open, Low Z, 1.5 hp Max Output Power, 575/600V AC, 3.4 A Output Current - Max (MPN KDRMA46L1)
KDR LINE REACTORS
Input Line Reactor: Open, Low Z, 1.5 hp Max Output Power, 575/600V AC, 3.4 A Output Current - Max (MPN KDRMA46L1)
Input Line Reactor: Open, High Z, 15 hp Max Output Power, 575/600V AC, 18.5 A Output Current - Max (MPN KDRULB44H)
KDR LINE REACTORS
Input Line Reactor: Open, High Z, 15 hp Max Output Power, 575/600V AC, 18.5 A Output Current - Max (MPN KDRULB44H)
KDR LINE REACTORS
KDR LINE REACTORS
Input Line Reactor: Open, High Z, 800 hp Max Output Power, 460/480V AC, 965 A Output Current - Max (MPN KDRULX2H)