We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

KDR LINE REACTORS Input Line Reactor, Open Style, 208/240V AC, 10 A, 2 hp - Input Line Reactors
KDR LINE REACTORSInput Line Reactors

KDR LINE REACTORS Input Line Reactor, Open Style, 208/240V AC, 10 A, 2 hp

The KDR LINE REACTORS Input Line Reactor: Open (MPN KDRMA26H1) is a High Z, 10 A Output Current - Max input line reactor operating at 208/240V AC with a 2 hp Max Output Power. 3G Electric interprets your demand for…

SKU 3G-OTH-622323

Brand
KDR LINE REACTORS
Item
Input Line Reactor, Open Style, 208/240V AC, 10 A, 2 hp
Part Number
KDRMA26H1
Category
Input Line Reactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

KDR LINE REACTORS
Manufacturer Part Number
KDRMA26H1
Type
High Z, 10 A Output Current - Max
AC
208/240V
Max Output Power
2 hp

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

KDR LINE REACTORS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KDR LINE REACTORS Input Line Reactor: Open (MPN KDRMA26H1) is a High Z, 10 A Output Current - Max input line reactor operating at 208/240V AC with a 2 hp Max Output Power. 3G Electric interprets your demand for this specific KDR component and delivers it as part of our broad industrial supply across 14 departments, with specialist depth in electrical controls and power transmission.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is a KDR input line reactor used for?

A KDR input line reactor protects variable frequency drives and motor controllers from power line harmonics, voltage spikes, and current distortion. It smooths incoming AC power to reduce electrical noise and improve equipment reliability in industrial automation and HVAC systems.

What are the specifications of the KDRMA26H1 input line reactor?

The KDRMA26H1 is an open-style, high-impedance input line reactor rated for 208/240V AC, 10 A maximum output current, and 2 hp maximum output power. It is designed for industrial motor drive applications requiring harmonic mitigation and surge protection.

Where to buy KDR line reactors worldwide?

3G Electric supplies the KDRMA26H1 input line reactor to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. As a global industrial solutions provider, we source and deliver genuine KDR components across 14 departments including electrical controls and power transmission.

How to select the right input line reactor for a motor drive?

Select an input line reactor by matching its voltage rating (e.g., 208/240V AC), current rating (e.g., 10 A), and impedance type (e.g., high Z) to your variable frequency drive's input specifications. The KDRMA26H1 supports up to 2 hp motors. Always consult the drive manufacturer's guidelines for proper sizing.

Not sure this is the right part? Photo-identify it

KDR LINE REACTORS Products

3G Electric supplies KDR LINE REACTORS input line reactors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Open-style high-impedance input line reactor rated for 208/240V AC, 11 A maximum output current, and 3 hp maximum output power. Used to protect variable frequency drives and motor controllers from power line harmonics, surges, and voltage spikes, smoothing current draw and reducing electrical noise
KDR LINE REACTORS
Open-style high-impedance input line reactor rated for 208/240V AC, 11 A maximum output current, and 3 hp maximum output power. Used to protect variable frequency drives and motor controllers from power line harmonics, surges, and voltage spikes, smoothing current draw and reducing electrical noise
Open-style input line reactor rated for 208/240V AC, 80 A maximum output current, and 25 hp maximum output power. Low impedance design reduces harmonics, limits inrush current, and smooths voltage spikes. Used to protect variable frequency drives and other sensitive equipment from power line disturbances in industrial motor control systems
KDR LINE REACTORS
Open-style input line reactor rated for 208/240V AC, 80 A maximum output current, and 25 hp maximum output power. Low impedance design reduces harmonics, limits inrush current, and smooths voltage spikes. Used to protect variable frequency drives and other sensitive equipment from power line disturbances in industrial motor control systems
Open-style input line reactor for 208/240V AC systems. Low impedance design with 12 A maximum output current and 3 hp maximum output power. Used to protect variable frequency drives and motor controllers from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, and pump systems
KDR LINE REACTORS
Open-style input line reactor for 208/240V AC systems. Low impedance design with 12 A maximum output current and 3 hp maximum output power. Used to protect variable frequency drives and motor controllers from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, and pump systems
High-impedance open-style input line reactor rated for 208/240V AC with a maximum output current of 47 A and maximum output power of 15 hp. Used to protect variable frequency drives and motor controllers from power line harmonics, voltage spikes, and current surges in industrial applications such as machining, HVAC, and material handling systems
KDR LINE REACTORS
High-impedance open-style input line reactor rated for 208/240V AC with a maximum output current of 47 A and maximum output power of 15 hp. Used to protect variable frequency drives and motor controllers from power line harmonics, voltage spikes, and current surges in industrial applications such as machining, HVAC, and material handling systems
Open-style low impedance input line reactor rated for 208/240V AC, 420 A maximum output current, and 150 hp maximum output power. Used to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, and pump applications
KDR LINE REACTORS
Open-style low impedance input line reactor rated for 208/240V AC, 420 A maximum output current, and 150 hp maximum output power. Used to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, and pump applications
Open-style input line reactor rated for 208/240V AC, 92 A maximum output current, and 30 hp maximum output power. Designed to protect variable frequency drives and motor controllers from power line harmonics, voltage spikes, and current distortion in industrial motor drive applications
KDR LINE REACTORS
Open-style input line reactor rated for 208/240V AC, 92 A maximum output current, and 30 hp maximum output power. Designed to protect variable frequency drives and motor controllers from power line harmonics, voltage spikes, and current distortion in industrial motor drive applications

More from KDR LINE REACTORS

View all KDR LINE REACTORS parts
Open-style input line reactor rated for 460/480V AC with a maximum output current of 240 A and maximum output power of 200 hp. Provides high impedance to reduce harmonics, limit inrush current, and smooth voltage spikes in motor drive systems. Suitable for use with variable frequency drives and other industrial equipment requiring input line reactance
KDR LINE REACTORS
Open-style input line reactor rated for 460/480V AC with a maximum output current of 240 A and maximum output power of 200 hp. Provides high impedance to reduce harmonics, limit inrush current, and smooth voltage spikes in motor drive systems. Suitable for use with variable frequency drives and other industrial equipment requiring input line reactance
Open-style low-impedance input line reactor rated for 575/600V AC, 125 A maximum output current, and 125 hp maximum output power. Designed for three-phase industrial power systems to protect variable frequency drives and motor controllers from power line disturbances, reduce harmonics, limit inrush current, and smooth voltage spikes
KDR LINE REACTORS
Open-style low-impedance input line reactor rated for 575/600V AC, 125 A maximum output current, and 125 hp maximum output power. Designed for three-phase industrial power systems to protect variable frequency drives and motor controllers from power line disturbances, reduce harmonics, limit inrush current, and smooth voltage spikes
Open-style low impedance input line reactor rated for 575/600V AC, 192 A maximum output current, and 200 hp maximum output power. Used to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, pumping, and material handling applications
KDR LINE REACTORS
Open-style low impedance input line reactor rated for 575/600V AC, 192 A maximum output current, and 200 hp maximum output power. Used to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, pumping, and material handling applications
Low impedance input line reactor rated for 460/480V AC with 0.5 hp max output power and 9.7 W watts loss. Used to protect variable frequency drives and motor systems from power line disturbances, reduce harmonics, limit inrush current, and smooth voltage spikes in industrial machinery
KDR LINE REACTORS
Low impedance input line reactor rated for 460/480V AC with 0.5 hp max output power and 9.7 W watts loss. Used to protect variable frequency drives and motor systems from power line disturbances, reduce harmonics, limit inrush current, and smooth voltage spikes in industrial machinery
This input line reactor is designed for use with variable frequency drives and motor systems to mitigate harmonics, voltage spikes, and current distortion. It is a Low Z type with a maximum output power of 60 hp, rated for 208/240V AC, and has a watts loss of 209 W. The UL Type 1 enclosure allows for general-purpose indoor installation
KDR LINE REACTORS
This input line reactor is designed for use with variable frequency drives and motor systems to mitigate harmonics, voltage spikes, and current distortion. It is a Low Z type with a maximum output power of 60 hp, rated for 208/240V AC, and has a watts loss of 209 W. The UL Type 1 enclosure allows for general-purpose indoor installation
Low-impedance open-style input line reactor for 208/240V AC systems. Rated 211 A maximum output current and 75 hp maximum output power. Used to mitigate harmonics, reduce voltage spikes, and smooth current draw in motor drive applications
KDR LINE REACTORS
Low-impedance open-style input line reactor for 208/240V AC systems. Rated 211 A maximum output current and 75 hp maximum output power. Used to mitigate harmonics, reduce voltage spikes, and smooth current draw in motor drive applications
KDR LINE REACTORS
KDR LINE REACTORS
This input line reactor is a High Z type rated for 575/600V AC with a maximum output power of 1500 hp and 2985 W watts loss. It is used to protect variable frequency drives and motor systems from power line disturbances, harmonics, and voltage spikes in industrial applications such as pumps, conveyors, and compressors
This input line reactor is a High Z unit rated for 460/480V AC with a maximum output power of 5.5 hp and 66.3 W watts loss. It is designed to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current surges. Typical applications include industrial automation, HVAC, and pump systems where power quality improvement is required
KDR LINE REACTORS
This input line reactor is a High Z unit rated for 460/480V AC with a maximum output power of 5.5 hp and 66.3 W watts loss. It is designed to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current surges. Typical applications include industrial automation, HVAC, and pump systems where power quality improvement is required