KDR LINE REACTORS KDRC3HE01 Input Line Reactor - Input Line Reactors
KDR LINE REACTORSInput Line Reactors

KDR LINE REACTORS KDRC3HE01 Input Line Reactor

The KDR LINE REACTORS Input Line Reactor (UL Type 1, MPN KDRC3HE01) is a High Z reactor rated for 460/480V AC, 20 hp Max Output Power, and 108 W Watts Loss. 3G Electric interprets your demand for this OEM-specified…

SKU 3G-OTH-622359

Brand
KDR LINE REACTORS
Item
KDRC3HE01 Input Line Reactor
Part Number
KDRC3HE01
Category
Input Line Reactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

KDR LINE REACTORS
Manufacturer Part Number
KDRC3HE01
Type
High Z
AC
460/480V
Watts Loss
108 W
Max Output Power
20 hp

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

KDR LINE REACTORS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KDR LINE REACTORS Input Line Reactor (UL Type 1, MPN KDRC3HE01) is a High Z reactor rated for 460/480V AC, 20 hp Max Output Power, and 108 W Watts Loss. 3G Electric interprets your demand for this OEM-specified component and delivers it across 14 industrial departments, with specialist depth in combustion, pumps, and controls as an authorised distributor.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is a KDR line reactor used for?

A KDR line reactor protects variable frequency drives and motor controllers from power line disturbances. It reduces harmonics, limits inrush current, and smooths voltage spikes in industrial machinery. 3G Electric supplies this OEM-specified component across 14 industrial departments, with specialist depth in combustion, pumps, and controls.

What are the specifications of the KDRC3HE01 input line reactor?

The KDRC3HE01 is a UL Type 1, High Z input line reactor rated for 460/480V AC, 20 hp max output power, and 108 W watts loss. It is designed for industrial motor control applications. 3G Electric sources this KDR LINE REACTORS component and delivers it globally.

Where to buy a KDR line reactor worldwide?

3G Electric supplies the KDR LINE REACTORS input line reactor worldwide. We handle full logistics, customs clearance, and delivery to your facility. As a global industrial solutions provider, we interpret your demand and deliver genuine OEM-specified components like the KDRC3HE01 across 14 industrial departments.

How to select the right line reactor for a 20 hp motor?

Select a line reactor with voltage matching your system (e.g., 460/480V AC) and a current rating suitable for the motor's full load amps. The KDRC3HE01 is a High Z reactor designed for 20 hp output. For application guidance, contact 3G Electric; we provide technical support across industrial categories including pumps and controls.

Not sure this is the right part? Photo-identify it

KDR LINE REACTORS Products

3G Electric supplies KDR LINE REACTORS input line reactors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from KDR LINE REACTORS

View all KDR LINE REACTORS parts
Open-style input line reactor rated for 460/480V AC with a maximum output current of 240 A and maximum output power of 200 hp. Provides high impedance to reduce harmonics, limit inrush current, and smooth voltage spikes in motor drive systems. Suitable for use with variable frequency drives and other industrial equipment requiring input line reactance
KDR LINE REACTORS
Open-style input line reactor rated for 460/480V AC with a maximum output current of 240 A and maximum output power of 200 hp. Provides high impedance to reduce harmonics, limit inrush current, and smooth voltage spikes in motor drive systems. Suitable for use with variable frequency drives and other industrial equipment requiring input line reactance
Open-style low-impedance input line reactor rated for 575/600V AC, 125 A maximum output current, and 125 hp maximum output power. Designed for three-phase industrial power systems to protect variable frequency drives and motor controllers from power line disturbances, reduce harmonics, limit inrush current, and smooth voltage spikes
KDR LINE REACTORS
Open-style low-impedance input line reactor rated for 575/600V AC, 125 A maximum output current, and 125 hp maximum output power. Designed for three-phase industrial power systems to protect variable frequency drives and motor controllers from power line disturbances, reduce harmonics, limit inrush current, and smooth voltage spikes
Open-style low impedance input line reactor rated for 575/600V AC, 192 A maximum output current, and 200 hp maximum output power. Used to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, pumping, and material handling applications
KDR LINE REACTORS
Open-style low impedance input line reactor rated for 575/600V AC, 192 A maximum output current, and 200 hp maximum output power. Used to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, pumping, and material handling applications
Low impedance input line reactor rated for 460/480V AC with 0.5 hp max output power and 9.7 W watts loss. Used to protect variable frequency drives and motor systems from power line disturbances, reduce harmonics, limit inrush current, and smooth voltage spikes in industrial machinery
KDR LINE REACTORS
Low impedance input line reactor rated for 460/480V AC with 0.5 hp max output power and 9.7 W watts loss. Used to protect variable frequency drives and motor systems from power line disturbances, reduce harmonics, limit inrush current, and smooth voltage spikes in industrial machinery
This input line reactor is designed for use with variable frequency drives and motor systems to mitigate harmonics, voltage spikes, and current distortion. It is a Low Z type with a maximum output power of 60 hp, rated for 208/240V AC, and has a watts loss of 209 W. The UL Type 1 enclosure allows for general-purpose indoor installation
KDR LINE REACTORS
This input line reactor is designed for use with variable frequency drives and motor systems to mitigate harmonics, voltage spikes, and current distortion. It is a Low Z type with a maximum output power of 60 hp, rated for 208/240V AC, and has a watts loss of 209 W. The UL Type 1 enclosure allows for general-purpose indoor installation
Low-impedance open-style input line reactor for 208/240V AC systems. Rated 211 A maximum output current and 75 hp maximum output power. Used to mitigate harmonics, reduce voltage spikes, and smooth current draw in motor drive applications
KDR LINE REACTORS
Low-impedance open-style input line reactor for 208/240V AC systems. Rated 211 A maximum output current and 75 hp maximum output power. Used to mitigate harmonics, reduce voltage spikes, and smooth current draw in motor drive applications
KDR LINE REACTORS
KDR LINE REACTORS
This input line reactor is a High Z type rated for 575/600V AC with a maximum output power of 1500 hp and 2985 W watts loss. It is used to protect variable frequency drives and motor systems from power line disturbances, harmonics, and voltage spikes in industrial applications such as pumps, conveyors, and compressors
This input line reactor is a High Z unit rated for 460/480V AC with a maximum output power of 5.5 hp and 66.3 W watts loss. It is designed to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current surges. Typical applications include industrial automation, HVAC, and pump systems where power quality improvement is required
KDR LINE REACTORS
This input line reactor is a High Z unit rated for 460/480V AC with a maximum output power of 5.5 hp and 66.3 W watts loss. It is designed to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current surges. Typical applications include industrial automation, HVAC, and pump systems where power quality improvement is required