We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

JOHNSON CONTROLS High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi - Single-Pressure Controls
JOHNSON CONTROLSSingle-Pressure Controls

JOHNSON CONTROLS High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi

The JOHNSON CONTROLS P70KA-7C is a High Pressure Control: High Limit, categorized as a Single-Pressure Control. It features a SPST contact form, rated for 208/240V AC, with a switch action of Open on Rise and a…

SKU 3G-OTH-69166

Also listed as: P70KA7C · P70KA 7C

Brand
JOHNSON CONTROLS
Item
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi
Category
Single-Pressure Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

JOHNSON CONTROLS
Manufacturer Part Number
P70KA-7C
Type
Manual Reset, 50 psi to 500 psi, Close on Rise/Open on Rise, SPST
Contact Form
SPST
Rated Voltage
208/240V AC
Switch Action
Open on Rise

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

JOHNSON CONTROLS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The JOHNSON CONTROLS P70KA-7C is a High Pressure Control: High Limit, categorized as a Single-Pressure Control. It features a SPST contact form, rated for 208/240V AC, with a switch action of Open on Rise and a manual reset, operating within a 50 psi to 500 psi range.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Johnson Controls P70KA-7C high-pressure control used for?

The Johnson Controls P70KA-7C is a single-pressure control used as a high-limit safety device in industrial refrigeration, HVAC, and process systems. It opens on rising pressure to protect compressors and equipment from overpressure conditions, with a manual reset requiring operator intervention after a trip.

What are the specifications of the Johnson Controls P70KA-7C?

The Johnson Controls P70KA-7C is a SPST high-pressure control with a range of 50 psi to 500 psi. It is rated for 208/240V AC, features an open-on-rise switch action, and includes a manual reset. The contact form is SPST, and the manufacturer part number is P70KA-7C.

Where to buy the Johnson Controls P70KA-7C worldwide?

3G Electric supplies the Johnson Controls P70KA-7C worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time; we source and deliver this single-pressure control to any country.

How to install the Johnson Controls P70KA-7C high-pressure control?

Install the Johnson Controls P70KA-7C by mounting it on the refrigeration or compressor discharge line. Connect the SPST contacts per the wiring diagram for 208/240V AC. Set the cut-out pressure within the 50 psi to 500 psi range. After a trip, manually reset the control by pressing the reset button.

Used in

Common applications for JOHNSON CONTROLS
Industrial refrigeration — Johnson Controls P170SA-1C dual pressure control for compressor protection in ammonia or halocarbon systems
Chiller plant automation — Johnson Controls VA7810-HGA-2 electric globe valve actuator for modulating chilled water flow in VG7000 series valves
Pneumatic HVAC retrofit — Johnson Controls T-4002-302 conversion kit for upgrading existing Robertshaw thermostats in commercial buildings
Cooling tower water management — Johnson Controls V-4332-1007 pneumatically actuated diaphragm valve for 3-way diverting of water flow
Boiler fuel oil pressure monitoring — Johnson Controls P545NCB-25C electronic lube oil pressure control with alarm for burner management systems
Process pressure sensing — Johnson Controls P599AAPS105C pressure transmitter with IP67 rating for washdown zones in food and beverage plants

JOHNSON CONTROLS Products

3G Electric supplies JOHNSON CONTROLS single-pressure controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
High Pressure Control: High Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P70CA-61C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P70CA-61C)
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Close on Rise/Open on Rise, SPST (MPN P70KA-1C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Close on Rise/Open on Rise, SPST (MPN P70KA-1C)
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-2C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-2C)
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, 35 psi to 200 psi, Close on Rise (MPN P70KA-7)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, 35 psi to 200 psi, Close on Rise (MPN P70KA-7)
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-1C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-1C)
High Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi, Open on Rise (MPN P70CA-3C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi, Open on Rise (MPN P70CA-3C)

More from JOHNSON CONTROLS

View all JOHNSON CONTROLS parts
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Fall (MPN P70AB-2C)
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Fall (MPN P70AB-2C)
Pressure Cut-Out Control: Low Limit, Manual Reset, 7 psi to 40 psi, Open on Fall, SPST, 1/4 in Sweat (MPN P20BB-1C)
JOHNSON CONTROLS
Pressure Cut-Out Control: Low Limit, Manual Reset, 7 psi to 40 psi, Open on Fall, SPST, 1/4 in Sweat (MPN P20BB-1C)
Single Pressure Control: Low Limit, Auto Reset, 12 in Hg to 80 psi, 5 psi to 35 psi, Open on Fall (MPN P170AB-12C)
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Auto Reset, 12 in Hg to 80 psi, 5 psi to 35 psi, Open on Fall (MPN P170AB-12C)
Single Pressure Control: Low Limit, Manual Reset, 20 in Hg to 100 psi, Open on Fall, SPST (MPN P70BA-1C)
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Manual Reset, 20 in Hg to 100 psi, Open on Fall, SPST (MPN P70BA-1C)
High Pressure Control: High Limit, Manual Reset, 200 psi to 610 psi, Open on Rise, SPST (MPN P70DA-400C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 200 psi to 610 psi, Open on Rise, SPST (MPN P70DA-400C)
Single Pressure Control: High Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P70CA-1C)
JOHNSON CONTROLS
Single Pressure Control: High Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P70CA-1C)
Pressure Cut-Out Control: High Limit, Manual Reset, 400 psi to 600 psi, Open on Rise, SPST (MPN P20DA-116C)
JOHNSON CONTROLS
Pressure Cut-Out Control: High Limit, Manual Reset, 400 psi to 600 psi, Open on Rise, SPST (MPN P20DA-116C)
Single Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi, Open on Rise (MPN P170CA-3C)
JOHNSON CONTROLS
Single Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi, Open on Rise (MPN P170CA-3C)