JOHNSON CONTROLS Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi - Single-Pressure Controls
JOHNSON CONTROLSSingle-Pressure Controls

JOHNSON CONTROLS Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi

The JOHNSON CONTROLS Single Pressure Control: Low Limit (MPN P70AA-5C) is a single-pressure control with an SPST contact form, rated for 120V AC. It features an Open on Fall switch action and auto reset, with a…

SKU 3G-OTH-69019

Also listed as: P70AA5C · P70AA 5C

Brand
JOHNSON CONTROLS
Item
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi
Category
Single-Pressure Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

JOHNSON CONTROLS
Manufacturer Part Number
P70AA-5C
Type
Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Fall
Contact Form
SPST
Rated Voltage
120V AC
Switch Action
Open on Fall

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

JOHNSON CONTROLS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The JOHNSON CONTROLS Single Pressure Control: Low Limit (MPN P70AA-5C) is a single-pressure control with an SPST contact form, rated for 120V AC. It features an Open on Fall switch action and auto reset, with a pressure range of 20 in Hg to 100 psi and a differential of 7 psi to 50 psi.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Johnson Controls P70AA-5C single pressure control used for?

The Johnson Controls P70AA-5C is a low-limit single pressure control used in HVAC and refrigeration systems to protect equipment by opening its SPST contacts on a fall in pressure. It auto-resets when pressure rises above the differential, preventing damage from low-pressure conditions.

What are the specifications of the Johnson Controls P70AA-5C?

The Johnson Controls P70AA-5C is a single-pressure control with SPST contact form, rated for 120V AC. It has an Open on Fall switch action and auto reset, with a pressure range of 20 in Hg to 100 psi and a differential of 7 psi to 50 psi. The manufacturer part number is P70AA-5C.

Where to buy the Johnson Controls P70AA-5C worldwide?

You can source the Johnson Controls P70AA-5C through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time on this single pressure control.

How to select a Johnson Controls P70AA-5C pressure control?

To select the Johnson Controls P70AA-5C, verify your system requires a low-limit, auto-reset control with Open on Fall action. Confirm the pressure range (20 in Hg to 100 psi) and differential (7 psi to 50 psi) match your application. Ensure the SPST contacts and 120V AC rating are compatible with your circuit.

Used in

Common applications for JOHNSON CONTROLS
Industrial refrigeration — Johnson Controls P170SA-1C dual pressure control for compressor protection in ammonia or halocarbon systems
Chiller plant automation — Johnson Controls VA7810-HGA-2 electric globe valve actuator for modulating chilled water flow in VG7000 series valves
Pneumatic HVAC retrofit — Johnson Controls T-4002-302 conversion kit for upgrading existing Robertshaw thermostats in commercial buildings
Cooling tower water management — Johnson Controls V-4332-1007 pneumatically actuated diaphragm valve for 3-way diverting of water flow
Boiler fuel oil pressure monitoring — Johnson Controls P545NCB-25C electronic lube oil pressure control with alarm for burner management systems
Process pressure sensing — Johnson Controls P599AAPS105C pressure transmitter with IP67 rating for washdown zones in food and beverage plants

JOHNSON CONTROLS Products

3G Electric supplies JOHNSON CONTROLS single-pressure controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Fall (MPN P70AB-2C)
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Fall (MPN P70AB-2C)
Single Pressure Control: Low Limit, Auto Reset, 12 in Hg to 80 psi, 5 psi to 35 psi, Open on Fall (MPN P70AB-12C)
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Auto Reset, 12 in Hg to 80 psi, 5 psi to 35 psi, Open on Fall (MPN P70AB-12C)
Low Pressure Control: Low Limit, Auto Reset, 100 psi to 100 psi, 7 psi to 50 psi, Open on Fall, SPST (MPN P70AB-2CQ)
JOHNSON CONTROLS
Low Pressure Control: Low Limit, Auto Reset, 100 psi to 100 psi, 7 psi to 50 psi, Open on Fall, SPST (MPN P70AB-2CQ)
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Fall (MPN P170AB-2C)
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Fall (MPN P170AB-2C)
Single Pressure Control: High Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P70CA-4C)
JOHNSON CONTROLS
Single Pressure Control: High Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P70CA-4C)
Single Pressure Control: Low Limit, Auto Reset, 12 in Hg to 80 psi, 5 psi to 35 psi, Open on Fall (MPN P170AB-12C)
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Auto Reset, 12 in Hg to 80 psi, 5 psi to 35 psi, Open on Fall (MPN P170AB-12C)

More from JOHNSON CONTROLS

View all JOHNSON CONTROLS parts
Single Pressure Control: Low Limit, Manual Reset, 20 in Hg to 100 psi, Open on Fall, SPST (MPN P70BA-1C)
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Manual Reset, 20 in Hg to 100 psi, Open on Fall, SPST (MPN P70BA-1C)
High Pressure Control: High Limit, Manual Reset, 200 psi to 610 psi, Open on Rise, SPST (MPN P70DA-400C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 200 psi to 610 psi, Open on Rise, SPST (MPN P70DA-400C)
Single Pressure Control: High Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P70CA-1C)
JOHNSON CONTROLS
Single Pressure Control: High Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P70CA-1C)
Pressure Cut-Out Control: High Limit, Manual Reset, 400 psi to 600 psi, Open on Rise, SPST (MPN P20DA-116C)
JOHNSON CONTROLS
Pressure Cut-Out Control: High Limit, Manual Reset, 400 psi to 600 psi, Open on Rise, SPST (MPN P20DA-116C)
Single Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi, Open on Rise (MPN P170CA-3C)
JOHNSON CONTROLS
Single Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi, Open on Rise (MPN P170CA-3C)
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P170CA-1C)
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P170CA-1C)
Single Pressure Control: High Limit, Manual Reset, 200 psi to 610 psi, Open on Rise, SPST (MPN P170DA-400C)
JOHNSON CONTROLS
Single Pressure Control: High Limit, Manual Reset, 200 psi to 610 psi, Open on Rise, SPST (MPN P170DA-400C)
High Pressure Control: Fan Cycling, Auto Reset, 200 psi to 610 psi, 60 psi to 150 psi, Open on Rise (MPN P70CA-400C)
JOHNSON CONTROLS
High Pressure Control: Fan Cycling, Auto Reset, 200 psi to 610 psi, 60 psi to 150 psi, Open on Rise (MPN P70CA-400C)