We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, CH4/O2, Calibration Gas - Calibration Gases for Portable Gas Detectors
INDUSTRIAL SCIENTIFICCalibration Gases for Portable Gas Detectors

INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, CH4/O2, Calibration Gas

The INDUSTRIAL SCIENTIFIC Calibration Gas (SKU 55PV02, MPN 18109256) is a CH4/O2 calibration gas with a background of Nitrogen and an Oxygen 18% mixture, supplied in a 103 L cylinder. Designed for use with Mfr. No…

SKU 3G-OTH-549912

Brand
INDUSTRIAL SCIENTIFIC
Item
Calibration Gas: Nitrogen, CH4/O2, Calibration Gas
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

INDUSTRIAL SCIENTIFIC
Manufacturer Part Number
18109256
Type
CH4/O2, Calibration Gas
Gas Mixture
Oxygen 18%
For Use With
Mfr. No. 09244
Background Gas
Nitrogen
Cylinder Capacity
103 L
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

INDUSTRIAL SCIENTIFIC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The INDUSTRIAL SCIENTIFIC Calibration Gas (SKU 55PV02, MPN 18109256) is a CH4/O2 calibration gas with a background of Nitrogen and an Oxygen 18% mixture, supplied in a 103 L cylinder. Designed for use with Mfr. No. 09244, this calibration gas supports the accurate testing and calibration of portable gas detectors.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is INDUSTRIAL SCIENTIFIC Calibration Gas 18109256 used for?

This CH4/O2 calibration gas with 18% oxygen in nitrogen is used to test and calibrate portable gas detectors, specifically for Mfr. No. 09244. It ensures accurate sensor response for methane and oxygen readings in industrial safety applications.

What are the specifications of INDUSTRIENTIFIC Calibration Gas 18109256?

The INDUSTRIAL SCIENTIFIC calibration gas (MPN 18109256) is a CH4/O2 mixture with 18% oxygen, balanced in nitrogen. It comes in a 103 L cylinder and is designed for use with Mfr. No. 09244. Background gas is nitrogen.

Where to buy INDUSTRIAL SCIENTIFIC Calibration Gas 18109256 worldwide?

3G Electric supplies the INDUSTRIAL SCIENTIFIC Calibration Gas 18109256 worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time on this calibration gas for portable gas detectors.

How to use INDUSTRIAL SCIENTIFIC Calibration Gas 18109256 for detector calibration?

Attach the 103 L cylinder to the detector's calibration adapter using the appropriate regulator. Apply the gas at the flow rate specified by the detector manufacturer. Allow readings to stabilize, then adjust the detector to match the certified gas values. Dispose of cylinder per local regulations.

INDUSTRIAL SCIENTIFIC Products

3G Electric supplies INDUSTRIAL SCIENTIFIC calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from INDUSTRIAL SCIENTIFIC

View all INDUSTRIAL SCIENTIFIC parts
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, +/-5% Accuracy, C5H12/H2S/O2/SO2, Calibration Gas (MPN 18109179). Key specifications — For Use With: Mfr. No. 02509; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Sulfur Dioxide 5 ppm.
INDUSTRIAL SCIENTIFIC
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, +/-5% Accuracy, C5H12/H2S/O2/SO2, Calibration Gas (MPN 18109179). Key specifications — For Use With: Mfr. No. 02509; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Sulfur Dioxide 5 ppm.
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, +/-5% Accuracy, CO, Calibration Gas, Cylinder (MPN 18102230). Key specifications — For Use With: Mfr. No. 00883; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Carbon Monoxide 50 ppm.
INDUSTRIAL SCIENTIFIC
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, +/-5% Accuracy, CO, Calibration Gas, Cylinder (MPN 18102230). Key specifications — For Use With: Mfr. No. 00883; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Carbon Monoxide 50 ppm.
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, CO2, Calibration Gas, 103 L Cylinder Capacity (MPN 18106153). Key specifications — For Use With: Mfr. No. 09244; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Carbon Dioxide 1,000 ppm.
INDUSTRIAL SCIENTIFIC
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, CO2, Calibration Gas, 103 L Cylinder Capacity (MPN 18106153). Key specifications — For Use With: Mfr. No. 09244; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Carbon Dioxide 1,000 ppm.
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, +/-5% Accuracy, H2, Calibration Gas, Cylinder (MPN 18102996). Key specifications — For Use With: Mfr. No. 05841; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Hydrogen 500 ppm.
INDUSTRIAL SCIENTIFIC
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, +/-5% Accuracy, H2, Calibration Gas, Cylinder (MPN 18102996). Key specifications — For Use With: Mfr. No. 05841; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Hydrogen 500 ppm.
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, +/-5% Accuracy, CH4/CO/CO2/H2S/O2, Calibration Gas (MPN 18109185). Key specifications — For Use With: Mfr. No. 09244; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Hydrogen sulfide 25 ppm.
INDUSTRIAL SCIENTIFIC
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, +/-5% Accuracy, CH4/CO/CO2/H2S/O2, Calibration Gas (MPN 18109185). Key specifications — For Use With: Mfr. No. 09244; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Hydrogen sulfide 25 ppm.
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, HCL, Calibration Gas, 58 L Cylinder Capacity (MPN 18102154). Key specifications — For Use With: Mfr. No. 00883; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Hydrogen Chloride 10 ppm.
INDUSTRIAL SCIENTIFIC
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, HCL, Calibration Gas, 58 L Cylinder Capacity (MPN 18102154). Key specifications — For Use With: Mfr. No. 00883; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Hydrogen Chloride 10 ppm.
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, CO, Calibration Gas, 103 L Cylinder Capacity (MPN 18106005). Key specifications — For Use With: Mfr. No. 00883; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Carbon Monoxide 25 ppm.
INDUSTRIAL SCIENTIFIC
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, CO, Calibration Gas, 103 L Cylinder Capacity (MPN 18106005). Key specifications — For Use With: Mfr. No. 00883; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Carbon Monoxide 25 ppm.
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, CO, Calibration Gas, 103 L Cylinder Capacity (MPN 18102302). Key specifications — For Use With: Mfr. No. 05841; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Carbon Monoxide 250 ppm.
INDUSTRIAL SCIENTIFIC
INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen, CO, Calibration Gas, 103 L Cylinder Capacity (MPN 18102302). Key specifications — For Use With: Mfr. No. 05841; Background Gas: Nitrogen; Brand: INDUSTRIAL SCIENTIFIC; Gas Mixture: Carbon Monoxide 250 ppm.