We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

INDUSTRIAL SCIENTIFIC Calibration Gas: Oxygen 18% in Nitrogen, CGA 660 - Calibration Gases for Portable Gas Detectors
INDUSTRIAL SCIENTIFICCalibration Gases for Portable Gas Detectors

INDUSTRIAL SCIENTIFIC Calibration Gas: Oxygen 18% in Nitrogen, CGA 660

The INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen (MPN 18109189) is a +/-5% accuracy calibration gas for portable gas detectors, featuring an Oxygen 18% gas mixture with a Nitrogen background gas and a CGA 660…

SKU 3G-OTH-549523

Brand
INDUSTRIAL SCIENTIFIC
Item
Calibration Gas: Oxygen 18% in Nitrogen, CGA 660
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

INDUSTRIAL SCIENTIFIC
Manufacturer Part Number
18109189
Type
+/-5% Accuracy, O2, Calibration Gas, CGA 660
CGA Number
CGA 660
Gas Mixture
Oxygen 18%
For Use With
Mfr. No. 03564
Background Gas
Nitrogen

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

INDUSTRIAL SCIENTIFIC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen (MPN 18109189) is a +/-5% accuracy calibration gas for portable gas detectors, featuring an Oxygen 18% gas mixture with a Nitrogen background gas and a CGA 660 connection. Designed for use with Mfr. No. 03564, this calibration gas ensures precise sensor verification for industrial safety applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is INDUSTRIAL SCIENTIFIC Calibration Gas 18109189 used for?

This calibration gas is used to verify and adjust the accuracy of portable gas detectors, specifically those compatible with Mfr. No. 03564. The Oxygen 18% mixture in a Nitrogen background ensures reliable sensor response for industrial safety monitoring in confined spaces or hazardous environments.

What are the specifications of INDUSTRIAL SCIENTIFIC Calibration Gas 18109189?

The INDUSTRIAL SCIENTIFIC Calibration Gas (MPN 18109189) has a +/-5% accuracy, contains an Oxygen 18% gas mixture with a Nitrogen background, and uses a CGA 660 connection. It is designed for use with Mfr. No. 03564 and is supplied by 3G Electric for industrial safety applications.

Where to buy INDUSTRIAL SCIENTIFIC Calibration Gas 18109189 worldwide?

3G Electric supplies the INDUSTRIAL SCIENTIFIC Calibration Gas 18109189 worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for a quote and lead time on this calibration gas for portable gas detectors.

How to use INDUSTRIAL SCIENTIFIC Calibration Gas 18109189 for detector calibration?

Attach the CGA 660 regulator to the calibration gas cylinder, then connect to the gas detector's inlet. Apply the Oxygen 18% mixture at the flow rate specified by the detector manufacturer. Allow the sensor to stabilize before comparing readings to the certified gas concentration for accurate calibration.

INDUSTRIAL SCIENTIFIC Products

3G Electric supplies INDUSTRIAL SCIENTIFIC calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from INDUSTRIAL SCIENTIFIC

View all INDUSTRIAL SCIENTIFIC parts
Calibration gas cylinder with +/-5% accuracy, containing a C5H12/O2 mixture with 18% Oxygen in a Nitrogen background. Used for calibrating portable gas detectors to ensure accurate readings in industrial environments
INDUSTRIAL SCIENTIFIC
Calibration gas cylinder with +/-5% accuracy, containing a C5H12/O2 mixture with 18% Oxygen in a Nitrogen background. Used for calibrating portable gas detectors to ensure accurate readings in industrial environments
Calibration gas mixture containing 5 ppm chlorine (CL2) balanced with nitrogen. Supplied in a 58 L cylinder. Used to verify and adjust the accuracy of portable gas detectors that sense chlorine
INDUSTRIAL SCIENTIFIC
Calibration gas mixture containing 5 ppm chlorine (CL2) balanced with nitrogen. Supplied in a 58 L cylinder. Used to verify and adjust the accuracy of portable gas detectors that sense chlorine
Calibration gas mixture containing 1,000 ppm hydrogen in nitrogen balance, supplied in a 103 L cylinder. Used for functional testing and calibration of portable gas detectors that require a hydrogen span gas, ensuring accurate sensor response in industrial safety environments
INDUSTRIAL SCIENTIFIC
Calibration gas mixture containing 1,000 ppm hydrogen in nitrogen balance, supplied in a 103 L cylinder. Used for functional testing and calibration of portable gas detectors that require a hydrogen span gas, ensuring accurate sensor response in industrial safety environments
Calibration gas for portable gas detectors, containing 5 ppm chlorine (CL2) in a nitrogen background. Supplied in a 58 L cylinder. Used for verifying and calibrating chlorine sensors in gas detection equipment
INDUSTRIAL SCIENTIFIC
Calibration gas for portable gas detectors, containing 5 ppm chlorine (CL2) in a nitrogen background. Supplied in a 58 L cylinder. Used for verifying and calibrating chlorine sensors in gas detection equipment
Hydrogen sulfide calibration gas mixture (10 ppm H2S in nitrogen) in a 58 L cylinder. Used to verify the accuracy of portable gas detectors that measure hydrogen sulfide in industrial safety applications
INDUSTRIAL SCIENTIFIC
Hydrogen sulfide calibration gas mixture (10 ppm H2S in nitrogen) in a 58 L cylinder. Used to verify the accuracy of portable gas detectors that measure hydrogen sulfide in industrial safety applications
Calibration gas mixture containing 2 ppm chlorine (CL2) in nitrogen background, supplied in a 58 L cylinder. Used for verifying and adjusting the accuracy of portable gas detectors that sense chlorine
INDUSTRIAL SCIENTIFIC
Calibration gas mixture containing 2 ppm chlorine (CL2) in nitrogen background, supplied in a 58 L cylinder. Used for verifying and adjusting the accuracy of portable gas detectors that sense chlorine
This calibration gas mixture contains 25 ppm hydrogen sulfide in a nitrogen background, with +/-5% accuracy. It is used to verify and adjust the response of portable gas detectors that monitor combustible gases (C3H8), carbon monoxide, hydrogen sulfide, and oxygen. Designed for use with Mfr. No. 05841
INDUSTRIAL SCIENTIFIC
This calibration gas mixture contains 25 ppm hydrogen sulfide in a nitrogen background, with +/-5% accuracy. It is used to verify and adjust the response of portable gas detectors that monitor combustible gases (C3H8), carbon monoxide, hydrogen sulfide, and oxygen. Designed for use with Mfr. No. 05841
Sulfur dioxide (SO2) calibration gas mixture at 5 ppm, balanced with nitrogen in a 58 L cylinder. Used for routine calibration of portable gas detectors to verify sensor accuracy for SO2 detection in industrial environments
INDUSTRIAL SCIENTIFIC
Sulfur dioxide (SO2) calibration gas mixture at 5 ppm, balanced with nitrogen in a 58 L cylinder. Used for routine calibration of portable gas detectors to verify sensor accuracy for SO2 detection in industrial environments