We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Honeywell Q347A1004 Direct Spark Igniter - Replacement HVACR Controls, Switches & Thermostats
HoneywellReplacement HVACR Controls, Switches & Thermostats

Honeywell Q347A1004 Direct Spark Igniter

Honeywell Replacement HVACR Controls, Switches & Thermostats. Specifications: Product Type: Direct Spark Igniter.

SKU 3G-OTH-75493

Brand
Honeywell
Item
Q347A1004 Direct Spark Igniter
Category
Replacement HVACR Controls, Switches & Thermostats
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Honeywell
Manufacturer Part Number
Q347A1004
Product Type
Direct Spark Igniter

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Honeywell Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Honeywell Replacement HVACR Controls, Switches & Thermostats. Specifications: Product Type: Direct Spark Igniter.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Honeywell Q347A1004 direct spark igniter used for?

The Honeywell Q347A1004 direct spark igniter is used in gas-fired heating equipment to ignite the burner by generating a high-voltage spark. It is commonly applied in commercial and industrial furnaces, boilers, and rooftop units where reliable ignition is required.

What are the specifications of the Honeywell Q347A1004?

The Honeywell Q347A1004 is a direct spark igniter with manufacturer part number Q347A1004. It is designed for replacement in HVACR controls, switches, and thermostats. This component provides a high-voltage spark for ignition in gas-fired systems.

Where to buy the Honeywell Q347A1004 worldwide?

You can source the Honeywell Q347A1004 direct spark igniter through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations, ensuring the part reaches your facility reliably.

How to install the Honeywell Q347A1004 direct spark igniter?

To install the Honeywell Q347A1004, first disconnect power and gas supply. Remove the old igniter and mount the new unit in the same position, ensuring the spark gap matches the manufacturer's specification. Reconnect wiring per the system diagram, then test for proper spark before restoring gas.

Used in

Common applications for Honeywell
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

Honeywell Products

3G Electric supplies Honeywell replacement hvacr controls, switches & thermostats. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Flame sensor for gas-fired burners in HVAC systems. Detects flame presence to ensure safe burner operation by signaling the control board to keep the gas valve open only when a flame is present. Replacement component for HVACR controls
Honeywell
Flame sensor for gas-fired burners in HVAC systems. Detects flame presence to ensure safe burner operation by signaling the control board to keep the gas valve open only when a flame is present. Replacement component for HVACR controls
Flame amplifier for use in industrial and commercial burner systems. Detects and amplifies flame signals from a flame sensor to verify flame presence and trigger safety shutdowns if flame is lost. Commonly applied in boilers, furnaces, and process heaters
Honeywell
Flame amplifier for use in industrial and commercial burner systems. Detects and amplifies flame signals from a flame sensor to verify flame presence and trigger safety shutdowns if flame is lost. Commonly applied in boilers, furnaces, and process heaters
This well is a replacement component for HVACR systems, designed to house temperature sensors or thermostats. It provides a protective enclosure for accurate temperature measurement in ducts, tanks, or pipes. Commonly used in commercial and industrial heating, ventilation, and refrigeration equipment
Honeywell
This well is a replacement component for HVACR systems, designed to house temperature sensors or thermostats. It provides a protective enclosure for accurate temperature measurement in ducts, tanks, or pipes. Commonly used in commercial and industrial heating, ventilation, and refrigeration equipment
Flame sensor for use in HVAC and combustion systems to detect flame presence. Signals control system to maintain fuel flow only when flame is confirmed, preventing unburned fuel accumulation. Direct replacement component for compatible burner control systems
Honeywell
Flame sensor for use in HVAC and combustion systems to detect flame presence. Signals control system to maintain fuel flow only when flame is confirmed, preventing unburned fuel accumulation. Direct replacement component for compatible burner control systems
Honeywell
Honeywell
This Honeywell pressure switch monitors and controls pressure levels in HVACR systems. It is used in commercial refrigeration, air conditioning, and heating equipment to protect compressors and maintain system performance
Flame sensor for use in HVAC burner systems. Detects flame presence in oil or gas burners, furnaces, and boilers to verify ignition and prevent unburned fuel accumulation. Suitable for replacement in commercial and industrial heating equipment
Honeywell
Flame sensor for use in HVAC burner systems. Detects flame presence in oil or gas burners, furnaces, and boilers to verify ignition and prevent unburned fuel accumulation. Suitable for replacement in commercial and industrial heating equipment

More from Honeywell

View all Honeywell parts
Line-voltage thermostat for 240 VAC electric heating systems. Controls baseboard heaters, radiant ceilings, or fan-forced heaters in commercial and industrial HVACR applications. Nonprogrammable design for simple temperature regulation
Honeywell
Line-voltage thermostat for 240 VAC electric heating systems. Controls baseboard heaters, radiant ceilings, or fan-forced heaters in commercial and industrial HVACR applications. Nonprogrammable design for simple temperature regulation
The Honeywell L91A1037 is an air switching valve used in HVACR systems to direct or switch airflow between circuits or components. It is commonly applied in commercial and industrial heating, ventilation, and air conditioning systems to control pneumatic actuators or dampers
Honeywell
The Honeywell L91A1037 is an air switching valve used in HVACR systems to direct or switch airflow between circuits or components. It is commonly applied in commercial and industrial heating, ventilation, and air conditioning systems to control pneumatic actuators or dampers
Auxiliary switch kit for HVACR systems, providing additional switching contacts for monitoring or control functions such as indicating valve position or activating alarms. Suitable for use in commercial and industrial heating, ventilation, and air conditioning equipment
Honeywell
Auxiliary switch kit for HVACR systems, providing additional switching contacts for monitoring or control functions such as indicating valve position or activating alarms. Suitable for use in commercial and industrial heating, ventilation, and air conditioning equipment
Rectification amplifier for use in combustion safety systems. Converts flame-rod AC signals to a DC output for burner management controllers. Suitable for flame detection in boilers, furnaces, and process heaters
Honeywell
Rectification amplifier for use in combustion safety systems. Converts flame-rod AC signals to a DC output for burner management controllers. Suitable for flame detection in boilers, furnaces, and process heaters
The Honeywell TR22/U is a temperature sensor designed for use in HVACR systems. It is suitable for monitoring and controlling temperature in commercial and industrial environments, including building automation, refrigeration, and process control applications
Honeywell
The Honeywell TR22/U is a temperature sensor designed for use in HVACR systems. It is suitable for monitoring and controlling temperature in commercial and industrial environments, including building automation, refrigeration, and process control applications
Temperature sensor for duct mounting in HVAC systems. Monitors air temperature within ductwork to enable control of heating, cooling, and ventilation. Suitable for commercial and industrial building applications
Honeywell
Temperature sensor for duct mounting in HVAC systems. Monitors air temperature within ductwork to enable control of heating, cooling, and ventilation. Suitable for commercial and industrial building applications
Resistor kit for HVACR control systems. Used for troubleshooting, calibration, or replacement of resistors in thermostats and control boards. Provides precise resistance values for service and maintenance
Honeywell
Resistor kit for HVACR control systems. Used for troubleshooting, calibration, or replacement of resistors in thermostats and control boards. Provides precise resistance values for service and maintenance
The Honeywell Q7330A1004/U is an ignition module designed for use in HVAC systems to control the ignition sequence for gas burners. It is suitable for commercial and industrial heating applications, including furnaces and boilers, ensuring safe and reliable burner startup
Honeywell
The Honeywell Q7330A1004/U is an ignition module designed for use in HVAC systems to control the ignition sequence for gas burners. It is suitable for commercial and industrial heating applications, including furnaces and boilers, ensuring safe and reliable burner startup