We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
HONEYWELL HOMEIntermittent Pilot Ignition Controls

HONEYWELL HOME R8184G4066 Integrated Furnace Control

The HONEYWELL HOME R8184G4066 is an Integrated Furnace Control, specifically an Oil Burner Control with Intermittent Pilot Ignition. It operates at a control voltage of 24 V AC and features a 15-second lockout time…

SKU 3G-OTH-68256

Brand
HONEYWELL HOME
Item
R8184G4066 Integrated Furnace Control
Category
Intermittent Pilot Ignition Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

HONEYWELL HOME
Manufacturer Part Number
R8184G4066
Product Type
Integrated Furnace Control
Control Voltage
24 V AC

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HONEYWELL HOME Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HONEYWELL HOME R8184G4066 is an Integrated Furnace Control, specifically an Oil Burner Control with Intermittent Pilot Ignition. It operates at a control voltage of 24 V AC and features a 15-second lockout time, with main valve output ratings of 7.4 A and 3.7 A.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Honeywell Home R8184G4066 oil burner control used for?

The Honeywell Home R8184G4066 is an Integrated Furnace Control designed for oil-fired heating systems. It manages intermittent pilot ignition and burner operation, providing a 15-second lockout time and main valve outputs of 7.4 A and 3.7 A at 24 V AC.

What are the specifications of the Honeywell Home R8184G4066?

The Honeywell Home R8184G4066 operates at 24 V AC control voltage with a 15-second lockout time. It has main valve output ratings of 7.4 A and 3.7 A. This Integrated Furnace Control supports intermittent pilot ignition for oil burners.

Where to buy the Honeywell Home R8184G4066 worldwide?

3G Electric supplies the Honeywell Home R8184G4066 worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to install the Honeywell Home R8184G4066 oil burner control?

Install the Honeywell Home R8184G4066 by disconnecting power, mounting the control per the manufacturer's instructions, and wiring the 24 V AC supply, burner motor, and valve outputs. Always follow local codes and the Honeywell Home manual for safe setup.

Used in

Common applications for HONEYWELL HOME
Residential HVAC — Honeywell Home TH115-A-120S/U thermostat for 7-day programmable temperature control in homes.
Light commercial buildings — Honeywell Home TL8230A1003 line-voltage thermostat for electric heating systems in offices.
Hydronic heating systems — Honeywell Home L4006E1117 immersion controller for high-limit temperature regulation in boilers.
Indoor air quality monitoring — Honeywell Home C7263A1008 air quality sensor for gas analysis in commercial facilities.
Furnace control — Honeywell Home ST9120U1011 timer controller for circulating fan timing in integrated furnace systems.
HVAC switching — Honeywell Home RA889A1001 switching relay for 24V AC control of zone valves or dampers.

HONEYWELL HOME Products

3G Electric supplies HONEYWELL HOME intermittent pilot ignition controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Universal hot surface ignition module for gas-fired heating equipment. Operates on 120V AC control voltage with a 4-second lockout and 32-second pre-purge timing. Replaces White-Rodgers OEM brands. Controls ignition sequence by energizing a hot surface igniter and monitoring flame presence
HONEYWELL HOME
Universal hot surface ignition module for gas-fired heating equipment. Operates on 120V AC control voltage with a 4-second lockout and 32-second pre-purge timing. Replaces White-Rodgers OEM brands. Controls ignition sequence by energizing a hot surface igniter and monitoring flame presence
Integrated furnace control for intermittent pilot ignition systems. Operates at 120V AC control voltage with a 270-second lockout, 15-second pre-purge, and 1.5 A main valve output. Designed as an OEM replacement for Goodman equipment. Used in gas furnaces to manage ignition sequencing and safety functions
WHITE-RODGERS
Integrated furnace control for intermittent pilot ignition systems. Operates at 120V AC control voltage with a 270-second lockout, 15-second pre-purge, and 1.5 A main valve output. Designed as an OEM replacement for Goodman equipment. Used in gas furnaces to manage ignition sequencing and safety functions
Integrated furnace control for intermittent pilot ignition systems. Operates at 120V AC control voltage with a 15-second pre-purge, 258-second lockout, and 1.5 A main valve output. Suitable for use as an OEM replacement in gas furnaces requiring 120V AC control
WHITE-RODGERS
Integrated furnace control for intermittent pilot ignition systems. Operates at 120V AC control voltage with a 15-second pre-purge, 258-second lockout, and 1.5 A main valve output. Suitable for use as an OEM replacement in gas furnaces requiring 120V AC control
Universal flame sensor accessory for oil-fired furnace control systems used in hot water and steam boiler applications. Includes 60-inch wire leads for flexible installation. Detects flame presence to support safe burner operation
HONEYWELL HOME
Universal flame sensor accessory for oil-fired furnace control systems used in hot water and steam boiler applications. Includes 60-inch wire leads for flexible installation. Detects flame presence to support safe burner operation
Oil primary control for managing burner operation in hot water and steam boiler systems. Designed for junction box mounting with an integrated display. Compatible with hydronic and forced air heating systems for residential and light commercial applications
HONEYWELL HOME
Oil primary control for managing burner operation in hot water and steam boiler systems. Designed for junction box mounting with an integrated display. Compatible with hydronic and forced air heating systems for residential and light commercial applications
This integrated furnace control is a hot surface ignition control designed for use in gas furnaces. It operates at 120V AC and features a 240-second lockout time, a 15-second pre-purge period, and a main valve output of 1.5 A. Suitable as a replacement for Carrier OEM systems
WHITE-RODGERS
This integrated furnace control is a hot surface ignition control designed for use in gas furnaces. It operates at 120V AC and features a 240-second lockout time, a 15-second pre-purge period, and a main valve output of 1.5 A. Suitable as a replacement for Carrier OEM systems

More from HONEYWELL HOME

View all HONEYWELL HOME parts
Intermittent pilot ignition control for gas-fired heating systems. Operates at 24V AC with a 15-second lockout time and 30-second pre-purge period. Main valve output rated at 24 A. Universal replacement for Honeywell OEM brands
HONEYWELL HOME
Intermittent pilot ignition control for gas-fired heating systems. Operates at 24V AC with a 15-second lockout time and 30-second pre-purge period. Main valve output rated at 24 A. Universal replacement for Honeywell OEM brands
This 24V AC intermittent pilot ignitor provides a 30-second pre-purge and a 15-second lockout for safe gas ignition. It is designed as a universal replacement for Honeywell OEM brands in furnaces, boilers, and other heating appliances
HONEYWELL HOME
This 24V AC intermittent pilot ignitor provides a 30-second pre-purge and a 15-second lockout for safe gas ignition. It is designed as a universal replacement for Honeywell OEM brands in furnaces, boilers, and other heating appliances