We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
HONEYWELL HOMEIntermittent Pilot Ignition Controls

HONEYWELL HOME Oil Burner Control: 24 V AC, 15 sec Lock Out

The HONEYWELL HOME R8184G4066 is an Integrated Furnace Control, specifically an Oil Burner Control with Intermittent Pilot Ignition. It operates at a control voltage of 24 V AC and features a 15-second lockout time…

SKU 3G-OTH-68256

Brand
HONEYWELL HOME
Item
Oil Burner Control: 24 V AC, 15 sec Lock Out
Category
Intermittent Pilot Ignition Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

HONEYWELL HOME
Manufacturer Part Number
R8184G4066
Product Type
Integrated Furnace Control
Control Voltage
24 V AC
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HONEYWELL HOME Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HONEYWELL HOME R8184G4066 is an Integrated Furnace Control, specifically an Oil Burner Control with Intermittent Pilot Ignition. It operates at a control voltage of 24 V AC and features a 15-second lockout time, with main valve output ratings of 7.4 A and 3.7 A.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Honeywell Home R8184G4066 oil burner control used for?

The Honeywell Home R8184G4066 is an Integrated Furnace Control designed for oil-fired heating systems. It manages intermittent pilot ignition and burner operation, providing a 15-second lockout time and main valve outputs of 7.4 A and 3.7 A at 24 V AC.

What are the specifications of the Honeywell Home R8184G4066?

The Honeywell Home R8184G4066 operates at 24 V AC control voltage with a 15-second lockout time. It has main valve output ratings of 7.4 A and 3.7 A. This Integrated Furnace Control supports intermittent pilot ignition for oil burners.

Where to buy the Honeywell Home R8184G4066 worldwide?

3G Electric supplies the Honeywell Home R8184G4066 worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to install the Honeywell Home R8184G4066 oil burner control?

Install the Honeywell Home R8184G4066 by disconnecting power, mounting the control per the manufacturer's instructions, and wiring the 24 V AC supply, burner motor, and valve outputs. Always follow local codes and the Honeywell Home manual for safe setup.

Used in

Common applications for HONEYWELL HOME
Residential HVAC — Honeywell Home TH115-A-120S/U thermostat for 7-day programmable temperature control in homes.
Light commercial buildings — Honeywell Home TL8230A1003 line-voltage thermostat for electric heating systems in offices.
Hydronic heating systems — Honeywell Home L4006E1117 immersion controller for high-limit temperature regulation in boilers.
Indoor air quality monitoring — Honeywell Home C7263A1008 air quality sensor for gas analysis in commercial facilities.
Furnace control — Honeywell Home ST9120U1011 timer controller for circulating fan timing in integrated furnace systems.
HVAC switching — Honeywell Home RA889A1001 switching relay for 24V AC control of zone valves or dampers.

HONEYWELL HOME Products

3G Electric supplies HONEYWELL HOME intermittent pilot ignition controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
Hot Surface Ignition Module: Universal, 120V AC, 4 sec Lock Out, 32 sec Pre-Purge, 3000 (MPN S8910U3000). Key specifications — Product Type: Hot Surface Ignition Module; Brand: HONEYWELL HOME; Control Voltage: 120V AC; Replacement for OEM Brands: White-Rodgers.
HONEYWELL HOME
Hot Surface Ignition Module: Universal, 120V AC, 4 sec Lock Out, 32 sec Pre-Purge, 3000 (MPN S8910U3000). Key specifications — Product Type: Hot Surface Ignition Module; Brand: HONEYWELL HOME; Control Voltage: 120V AC; Replacement for OEM Brands: White-Rodgers.
Ignition Control: OEM, 120V AC, 270 sec Lock Out, 15 sec Pre-Purge, 1.5 A Main Valve Output (MPN 50C51-707). Key specifications — Product Type: Integrated Furnace Control; Brand: WHITE-RODGERS; Control Voltage: 120V AC; Replacement for OEM Brands: Goodman.
WHITE-RODGERS
Ignition Control: OEM, 120V AC, 270 sec Lock Out, 15 sec Pre-Purge, 1.5 A Main Valve Output (MPN 50C51-707). Key specifications — Product Type: Integrated Furnace Control; Brand: WHITE-RODGERS; Control Voltage: 120V AC; Replacement for OEM Brands: Goodman.
Ignition Control: OEM, 120V AC, 258 sec Lock Out, 15 sec Pre-Purge, 1.5 A Main Valve Output (MPN 50V54-820). Key specifications — Product Type: Integrated Furnace Control; Brand: WHITE-RODGERS; Control Voltage: 120V AC; Replacement for OEM Brands: Trane.
WHITE-RODGERS
Ignition Control: OEM, 120V AC, 258 sec Lock Out, 15 sec Pre-Purge, 1.5 A Main Valve Output (MPN 50V54-820). Key specifications — Product Type: Integrated Furnace Control; Brand: WHITE-RODGERS; Control Voltage: 120V AC; Replacement for OEM Brands: Trane.
HONEYWELL HOME Hot Water and Steam Boiler Oil Burner Control: R7284U1004, Junction Box, Display. Key specifications — Includes: Display; Manufacturer Part Number: R7284U1004; Accessory Type: Oil Primary Control; Brand: HONEYWELL HOME; Compatible with Product Type: Hydronic and Forced Air Systems; Model Number: R7284U1004; Mounting Type: Junction Box; Product Type: Controls.
HONEYWELL HOME
HONEYWELL HOME Hot Water and Steam Boiler Oil Burner Control: R7284U1004, Junction Box, Display. Key specifications — Includes: Display; Manufacturer Part Number: R7284U1004; Accessory Type: Oil Primary Control; Brand: HONEYWELL HOME; Compatible with Product Type: Hydronic and Forced Air Systems; Model Number: R7284U1004; Mounting Type: Junction Box; Product Type: Controls.
HONEYWELL HOME Hot Water and Steam Boiler Oil Burner Control: C554A1463, Universal, C554A1463. Key specifications — Includes: 60 in Wire Leads; Manufacturer Part Number: C554A1463; Accessory Type: Flame Sensor; Brand: HONEYWELL HOME; Compatible with Product Type: Oil Fired Furnace Control Systems; Model Number: C554A1463; Mounting Type: Universal; Product Type: Controls.
HONEYWELL HOME
HONEYWELL HOME Hot Water and Steam Boiler Oil Burner Control: C554A1463, Universal, C554A1463. Key specifications — Includes: 60 in Wire Leads; Manufacturer Part Number: C554A1463; Accessory Type: Flame Sensor; Brand: HONEYWELL HOME; Compatible with Product Type: Oil Fired Furnace Control Systems; Model Number: C554A1463; Mounting Type: Universal; Product Type: Controls.
Ignition Control: OEM, 120V AC, 240 sec Lock Out, 15 sec Pre-Purge, 1.5 A Main Valve Output (MPN 21V51D-751). Key specifications — Product Type: Integrated Furnace Control; Brand: WHITE-RODGERS; Control Voltage: 120V AC; Replacement for OEM Brands: Carrier.
WHITE-RODGERS
Ignition Control: OEM, 120V AC, 240 sec Lock Out, 15 sec Pre-Purge, 1.5 A Main Valve Output (MPN 21V51D-751). Key specifications — Product Type: Integrated Furnace Control; Brand: WHITE-RODGERS; Control Voltage: 120V AC; Replacement for OEM Brands: Carrier.

More from HONEYWELL HOME

View all HONEYWELL HOME parts
Standing Pilot Module: Universal, 24V AC, 15 sec Lock Out, 30 sec Pre-Purge, 24 A Main Valve Output (MPN Y8610U6006). Key specifications — Product Type: Standing Pilot Module; Brand: HONEYWELL HOME; Control Voltage: 24V AC; Replacement for OEM Brands: Honeywell.
HONEYWELL HOME
Standing Pilot Module: Universal, 24V AC, 15 sec Lock Out, 30 sec Pre-Purge, 24 A Main Valve Output (MPN Y8610U6006). Key specifications — Product Type: Standing Pilot Module; Brand: HONEYWELL HOME; Control Voltage: 24V AC; Replacement for OEM Brands: Honeywell.
Intermittent Pilot Ignitor: Universal, 24V AC, 15 sec Lock Out, 30 sec Pre-Purge (MPN Y8610U4001). Key specifications — Product Type: Intermittent Pilot Ignitor; Brand: HONEYWELL HOME; Control Voltage: 24V AC; Replacement for OEM Brands: Honeywell.
HONEYWELL HOME
Intermittent Pilot Ignitor: Universal, 24V AC, 15 sec Lock Out, 30 sec Pre-Purge (MPN Y8610U4001). Key specifications — Product Type: Intermittent Pilot Ignitor; Brand: HONEYWELL HOME; Control Voltage: 24V AC; Replacement for OEM Brands: Honeywell.