HONEYWELL Gas Detection Tube for LP-1200 Pumps, Ammonia, 10-260 ppm, Pack of 10 - Gas Detection Tubes For Use In HONEYWELL LP-1200 Pumps
HONEYWELLGas Detection Tubes For Use In HONEYWELL LP-1200 Pumps

HONEYWELL Gas Detection Tube for LP-1200 Pumps, Ammonia, 10-260 ppm, Pack of 10

The HONEYWELL Detector Tube is a gas detection tube for use in HONEYWELL LP-1200 pumps, detecting ammonia across a measurement range of 10 to 260 ppm. Supplied as a pack of 10 (MPN H-10-100-12), it provides a…

SKU 3G-OTH-547978

Also listed as: H1010012 · H 10 100 12

Brand
HONEYWELL
Item
Gas Detection Tube for LP-1200 Pumps, Ammonia, 10-260 ppm, Pack of 10
Category
Gas Detection Tubes For Use In HONEYWELL LP-1200 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

HONEYWELL
Manufacturer Part Number
H-10-100-12
Type
Ammonia, 10 to 260 ppm, Ammonia, 10 PK
Gas Detected
Ammonia
Measurement Range
10 to 260 ppm

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HONEYWELL Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HONEYWELL Detector Tube is a gas detection tube for use in HONEYWELL LP-1200 pumps, detecting ammonia across a measurement range of 10 to 260 ppm. Supplied as a pack of 10 (MPN H-10-100-12), it provides a targeted solution for ammonia gas detection.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the HONEYWELL Detector Tube H-10-100-12 used for?

This HONEYWELL detector tube is used with LP-1200 pumps to measure ammonia gas concentrations from 10 to 260 ppm. It is essential for industrial safety in refrigeration, chemical processing, and wastewater treatment where ammonia leaks pose health risks. 3G Electric supplies this tube globally.

What are the specifications of the HONEYWELL Detector Tube H-10-100-12?

The HONEYWELL detector tube detects ammonia gas with a measurement range of 10 to 260 ppm. It is supplied in a pack of 10, with manufacturer part number H-10-100-12. Designed for use in HONEYWELL LP-1200 pumps, it provides accurate spot-check readings for industrial hygiene.

Where to buy HONEYWELL Detector Tube H-10-100-12 worldwide?

3G Electric supplies the HONEYWELL Detector Tube H-10-100-12 to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this ammonia detection tube.

How to use the HONEYWELL Detector Tube H-10-100-12 with an LP-1200 pump?

Break off both tips of the HONEYWELL detector tube, insert it into the LP-1200 pump inlet, and pull the handle to draw a sample. Follow the pump’s stroke count for the 10 to 260 ppm range. Read the stain length against the tube scale. Always use fresh tubes for accurate ammonia detection.

Used in

Common applications for HONEYWELL
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

HONEYWELL Products

3G Electric supplies HONEYWELL gas detection tubes for use in honeywell lp-1200 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from HONEYWELL

View all HONEYWELL parts
Gas detection tube for use with HONEYWELL LP-1200 pumps. Detects nitrogen dioxide in the range of 0.5 to 30 ppm. Supplied in a pack of 10. Suitable for industrial hygiene and environmental air monitoring applications
HONEYWELL
Gas detection tube for use with HONEYWELL LP-1200 pumps. Detects nitrogen dioxide in the range of 0.5 to 30 ppm. Supplied in a pack of 10. Suitable for industrial hygiene and environmental air monitoring applications
Gas detection tube for measuring trichloroethylene concentrations in air. Measurement range 5 to 100 ppm. Pack of 5 tubes for use with HONEYWELL LP-1200 pumps. Suitable for industrial hygiene and environmental air monitoring
HONEYWELL
Gas detection tube for measuring trichloroethylene concentrations in air. Measurement range 5 to 100 ppm. Pack of 5 tubes for use with HONEYWELL LP-1200 pumps. Suitable for industrial hygiene and environmental air monitoring
Gas detection tube for use with HONEYWELL LP-1200 pumps. Detects sulfur dioxide in the range of 2 to 30 ppm. Supplied as a pack of 10 tubes. Used for on-site gas analysis in industrial environments where sulfur dioxide may be present
HONEYWELL
Gas detection tube for use with HONEYWELL LP-1200 pumps. Detects sulfur dioxide in the range of 2 to 30 ppm. Supplied as a pack of 10 tubes. Used for on-site gas analysis in industrial environments where sulfur dioxide may be present
Gas detection tube for use with HONEYWELL LP-1200 pumps. Detects nitric acid in the range of 1 to 20 ppm. Supplied as a 10-pack for on-site atmospheric testing in industrial environments where nitric acid exposure may occur
HONEYWELL
Gas detection tube for use with HONEYWELL LP-1200 pumps. Detects nitric acid in the range of 1 to 20 ppm. Supplied as a 10-pack for on-site atmospheric testing in industrial environments where nitric acid exposure may occur
Gas detection tube for measuring water vapor concentrations from 0.05 to 1 mg/L. Designed for use with HONEYWELL LP-1200 pumps. Supplied in a pack of 10. Suitable for moisture monitoring in industrial gas analysis applications
HONEYWELL
Gas detection tube for measuring water vapor concentrations from 0.05 to 1 mg/L. Designed for use with HONEYWELL LP-1200 pumps. Supplied in a pack of 10. Suitable for moisture monitoring in industrial gas analysis applications
Gas detection tube for use with HONEYWELL LP-1200 pumps. Detects hydrocarbon gas in the range of 50 to 1,000 ppm. Supplied as a 10-pack of consumable tubes for direct-reading measurement in industrial environments
HONEYWELL
Gas detection tube for use with HONEYWELL LP-1200 pumps. Detects hydrocarbon gas in the range of 50 to 1,000 ppm. Supplied as a 10-pack of consumable tubes for direct-reading measurement in industrial environments
Gas detection tube for use with HONEYWELL LP-1200 pumps. Detects phosphine gas in the range of 25 to 500 ppm. Supplied as a 10-pack for field measurement of phosphine concentrations in applications such as fumigation and industrial hygiene
HONEYWELL
Gas detection tube for use with HONEYWELL LP-1200 pumps. Detects phosphine gas in the range of 25 to 500 ppm. Supplied as a 10-pack for field measurement of phosphine concentrations in applications such as fumigation and industrial hygiene
Gas detection tube for use with HONEYWELL LP-1200 pumps. Detects hydrogen sulfide in the range of 0.2 to 3 ppm. Supplied in a 10-pack. Suitable for industrial hygiene and safety monitoring in environments where H2S may be present
HONEYWELL
Gas detection tube for use with HONEYWELL LP-1200 pumps. Detects hydrogen sulfide in the range of 0.2 to 3 ppm. Supplied in a 10-pack. Suitable for industrial hygiene and safety monitoring in environments where H2S may be present