The HONEYWELL Calibration Gas: Air (SKU 600-0063-000, MPN 600-0063-000) is a +/-5% accuracy calibration gas for portable gas detectors, supplied in a 34 L cylinder with a CGA 600 fitting. The gas mixture is Benzene 5…

SKU 3G-OTH-550852

Also listed as: 6000063000 · 600 0063 000

Brand
HONEYWELL
Item
Calibration Gas: Air, +/-5% Accuracy, C6H6, Calibration Gas
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

HONEYWELL
Manufacturer Part Number
600-0063-000
Type
+/-5% Accuracy, C6H6, Calibration Gas
CGA Number
CGA 600
Gas Mixture
Benzene 5 ppm
For Use With
Bump Test Stations
Background Gas
Air
Cylinder Capacity
34 L

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HONEYWELL Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HONEYWELL Calibration Gas: Air (SKU 600-0063-000, MPN 600-0063-000) is a +/-5% accuracy calibration gas for portable gas detectors, supplied in a 34 L cylinder with a CGA 600 fitting. The gas mixture is Benzene 5 ppm with an Air background, designed for use with bump test stations.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is HONEYWELL calibration gas 600-0063-000 used for?

This HONEYWELL calibration gas is used to verify and adjust the accuracy of portable gas detectors, specifically for bump test stations. The 34 L cylinder contains Benzene 5 ppm in an Air background, ensuring detectors respond correctly to benzene exposure in industrial environments.

What are the specifications of HONEYWELL calibration gas 600-0063-000?

The HONEYWELL calibration gas (MPN 600-0063-000) has +/-5% accuracy, a 34 L cylinder capacity, and a CGA 600 fitting. The gas mixture is Benzene 5 ppm with an Air background gas, designed for use with bump test stations. It is supplied by 3G Electric.

Where to buy HONEYWELL calibration gas 600-0063-000 worldwide?

3G Electric supplies the HONEYWELL calibration gas 600-0063-000 worldwide. We handle full logistics, customs clearance, and delivery to your facility. Contact us for a quote and lead time on this Benzene 5 ppm calibration gas for portable gas detectors.

How to use HONEYWELL calibration gas 600-0063-000 for bump testing?

Connect the 34 L cylinder with CGA 600 fitting to your bump test station. Apply the Benzene 5 ppm mixture to the portable gas detector per the manufacturer's instructions. Verify the detector's alarm response and accuracy. Always follow safety data sheets for handling calibration gases.

Used in

Common applications for HONEYWELL
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

HONEYWELL Products

3G Electric supplies HONEYWELL calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from HONEYWELL

View all HONEYWELL parts
Calibration gas mixture containing 25 ppm hydrogen sulfide in nitrogen, with ±5% accuracy. Designed for use with GasAlert Series multi-gas monitors to verify and adjust sensor response. Fitted with a CGA 600 connection
HONEYWELL
Calibration gas mixture containing 25 ppm hydrogen sulfide in nitrogen, with ±5% accuracy. Designed for use with GasAlert Series multi-gas monitors to verify and adjust sensor response. Fitted with a CGA 600 connection
HONEYWELL
HONEYWELL
This calibration gas cylinder contains a mixture of 5 ppm sulfur dioxide in nitrogen, with a 58 L capacity and CGA C10 connection. It is used to verify and adjust the accuracy of portable gas detectors that sense sulfur dioxide in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas mixture of 10 ppm hydrogen cyanide in nitrogen, with ±10% accuracy. Supplied in a 58 L cylinder with CGA C10 fitting. Used for functional testing and calibration of portable gas detectors that sense hydrogen cyanide, typically with bump test stations
This calibration gas cylinder contains 10 ppm hydrogen cyanide in a nitrogen background, with +/-10% accuracy. It is used to verify and calibrate gas detection instruments in industrial safety applications. The 58 L cylinder features a CGA 600 fitting
HONEYWELL
This calibration gas cylinder contains 10 ppm hydrogen cyanide in a nitrogen background, with +/-10% accuracy. It is used to verify and calibrate gas detection instruments in industrial safety applications. The 58 L cylinder features a CGA 600 fitting
HONEYWELL
HONEYWELL
This calibration gas cylinder contains 50 ppm ammonia in nitrogen with +/-5% accuracy and a CGA C10 fitting. The 58 L capacity is used for verifying and calibrating portable gas detection instruments in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas mixture for portable gas detectors, containing Methane (2.5% LEL) and Oxygen 18% in a 58 L cylinder with CGA 600 connection. Used to verify and calibrate sensor response in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas mixture of 5 ppm phosphine in nitrogen, supplied in a 58 L cylinder with CGA C10 connection. Used for calibration of portable gas detectors that sense phosphine
This calibration gas mixture contains 100 ppm isobutylene in an air background, supplied in a 34 L cylinder with a CGA 600 fitting. It provides ±2% accuracy for verifying and calibrating portable gas detectors used in safety monitoring applications
HONEYWELL
This calibration gas mixture contains 100 ppm isobutylene in an air background, supplied in a 34 L cylinder with a CGA 600 fitting. It provides ±2% accuracy for verifying and calibrating portable gas detectors used in safety monitoring applications