We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

HACH Turbidity Meter LPV442.99.01012 - Turbidity Meters
HACHTurbidity Meters

HACH Turbidity Meter LPV442.99.01012

The HACH Turbidity Meter (SKU LPV442.99.01012, part number LPV442.99.01012) measures turbidity across a range of 0 to 175 EBC, with an accuracy of +/-10% of reading from 40 to 1000 NTU based on a Formazin Primary…

SKU 3G-OTH-371208

Also listed as: LPV4429901012 · LPV442 99 01012 · LPV442-99-01012

Brand
HACH
Item
Turbidity Meter LPV442.99.01012
Category
Turbidity Meters
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

HACH
Manufacturer Part Number
LPV442.99.01012
Type
LPV442.99.01012
Range
0 to 175 EBC
Includes
Stablcal Calibration Kit
Product Type
Turbidity Meter
Turbidity Accuracy
+/-10% of Reading from 40 - 1000 NTU based on Formazin Primary Standard (at 25 °C)

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HACH Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HACH Turbidity Meter (SKU LPV442.99.01012, part number LPV442.99.01012) measures turbidity across a range of 0 to 175 EBC, with an accuracy of +/-10% of reading from 40 to 1000 NTU based on a Formazin Primary Standard at 25 °C. It includes a Stablcal Calibration Kit for calibration support.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the HACH Turbidity Meter LPV442.99.01012 used for?

The HACH Turbidity Meter measures water clarity in industrial and municipal applications, including wastewater treatment and process monitoring. It quantifies suspended particles across a range of 0 to 175 EBC, with accuracy of +/-10% of reading from 40 to 1000 NTU based on a Formazin Primary Standard at 25 °C.

What are the specifications of the HACH Turbidity Meter LPV442.99.01012?

The HACH Turbidity Meter (part number LPV442.99.01012) has a measurement range of 0 to 175 EBC and turbidity accuracy of +/-10% of reading from 40 to 1000 NTU based on a Formazin Primary Standard at 25 °C. It includes a Stablcal Calibration Kit and is designed for reliable turbidity analysis.

Where to buy the HACH Turbidity Meter LPV442.99.01012 worldwide?

You can source the HACH Turbidity Meter LPV442.99.01012 from 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time on this turbidity meter.

How to calibrate the HACH Turbidity Meter LPV442.99.01012?

The HACH Turbidity Meter includes a Stablcal Calibration Kit for routine calibration. Follow the manufacturer's guidelines to prepare standards and perform calibration at 25 °C. Regular calibration ensures accuracy within +/-10% of reading from 40 to 1000 NTU based on Formazin Primary Standard.

Used in

Common applications for HACH
Municipal water treatment — HACH PHC20101 IntelliCAL pH electrode for pH monitoring in distribution systems
Industrial wastewater — HACH Chloride Test Kit (2438600) for chlorine residual analysis in effluent
Laboratory analysis — HACH Buffer Standard Solution S11M005 for calibrating pH meters in quality control labs
Environmental field testing — HACH Chemical Test Strips (2793828) for rapid water quality screening
Process water monitoring — HACH Probe LZW5056.97.0002 for ORP measurement in cooling towers
Wastewater treatment — HACH Water Quality Test Kit (2182000) for nitrite monitoring in biological treatment processes

HACH Products

3G Electric supplies HACH turbidity meters. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Turbidity meter with a measurement range of 0 to 700 NTU/FNU/TE/F/FTU. Accuracy is ±2% plus 0.01 NTU from 0 to 40 NTU. Includes two sample vials. Used for measuring water clarity in laboratory and field applications
HACH
Turbidity meter with a measurement range of 0 to 700 NTU/FNU/TE/F/FTU. Accuracy is ±2% plus 0.01 NTU from 0 to 40 NTU. Includes two sample vials. Used for measuring water clarity in laboratory and field applications
Turbidity meter with a measurement range of 0 to 4000 NTU and 0 NTU resolution. Accuracy is ±2% of reading plus 0.01 NTU from 0 to 1000 NTU, and ±5% of reading from 1000 to 4000 NTU based on Formazin Primary Standard (Ratio On). Includes power supply. Complies with CE, KC, EPA Method 180.1, and RCM standards. Suitable for water clarity measurement in drinking water treatment, wastewater monitoring, and process control applications
HACH
Turbidity meter with a measurement range of 0 to 4000 NTU and 0 NTU resolution. Accuracy is ±2% of reading plus 0.01 NTU from 0 to 1000 NTU, and ±5% of reading from 1000 to 4000 NTU based on Formazin Primary Standard (Ratio On). Includes power supply. Complies with CE, KC, EPA Method 180.1, and RCM standards. Suitable for water clarity measurement in drinking water treatment, wastewater monitoring, and process control applications
Turbidity meter for measuring water clarity in the range of 0 to 1000 NTU. Accuracy is ±2% of reading plus stray light. Includes USB connectivity for data transfer. Suitable for water quality monitoring in treatment plants and industrial processes
HACH
Turbidity meter for measuring water clarity in the range of 0 to 1000 NTU. Accuracy is ±2% of reading plus stray light. Includes USB connectivity for data transfer. Suitable for water quality monitoring in treatment plants and industrial processes
Portable turbidity meter for measuring water clarity in field and laboratory settings. Range of 0 to 1000 NTU with accuracy of ±2% of reading plus stray light. Includes silicone oil for maintaining optical precision. Suitable for water quality monitoring and process control applications
HACH
Portable turbidity meter for measuring water clarity in field and laboratory settings. Range of 0 to 1000 NTU with accuracy of ±2% of reading plus stray light. Includes silicone oil for maintaining optical precision. Suitable for water quality monitoring and process control applications
This calibration kit includes four bottle standards with concentrations of 100, 20, 800, and <0.1 NTU for calibrating turbidity instruments. Each bottle contains 100 mL of standard solution. Used in water quality testing to verify the accuracy of turbidity measurements
HACH
This calibration kit includes four bottle standards with concentrations of 100, 20, 800, and <0.1 NTU for calibrating turbidity instruments. Each bottle contains 100 mL of standard solution. Used in water quality testing to verify the accuracy of turbidity measurements
This calibration kit contains semi-solid turbidity standards at concentrations of 1,000 NTU, 20 NTU, 200 NTU, 4,000 NTU, 7,500 NTU, and less than 0.1 NTU. It is used for calibrating turbidity instruments in laboratory and industrial water quality testing applications
HACH
This calibration kit contains semi-solid turbidity standards at concentrations of 1,000 NTU, 20 NTU, 200 NTU, 4,000 NTU, 7,500 NTU, and less than 0.1 NTU. It is used for calibrating turbidity instruments in laboratory and industrial water quality testing applications

More from HACH

View all HACH parts
Turbidity meter for measuring water clarity in applications such as drinking water treatment, wastewater monitoring, and industrial process control. Range: 0 to 10000 NTU. Accuracy: ±2% of reading plus 0.01 FNU from 0 to 1000 FNU. Includes silicone oil
HACH
Turbidity meter for measuring water clarity in applications such as drinking water treatment, wastewater monitoring, and industrial process control. Range: 0 to 10000 NTU. Accuracy: ±2% of reading plus 0.01 FNU from 0 to 1000 FNU. Includes silicone oil
The HACH 2100Q01 turbidity meter measures water clarity over a range of 0 to 1000 NTU with an accuracy of ±2% of reading plus stray light. It includes an oiling cloth for maintenance. Suitable for monitoring water quality in treatment processes and environmental testing
HACH
The HACH 2100Q01 turbidity meter measures water clarity over a range of 0 to 1000 NTU with an accuracy of ±2% of reading plus stray light. It includes an oiling cloth for maintenance. Suitable for monitoring water quality in treatment processes and environmental testing
Turbidity meter with a measurement range of 0 to 10000 NTU and 0 NTU resolution. Accuracy is ±2% of reading plus 0.01 NTU from 0 to 1000 NTU, ±5% from 1000 to 4000 NTU, and ±10% from 4000 to 10000 NTU (Ratio on). Includes oiling cloth. Complies with CE, KC, RCM standards and EPA Method 180.1. Suitable for water clarity testing in laboratory and field applications
HACH
Turbidity meter with a measurement range of 0 to 10000 NTU and 0 NTU resolution. Accuracy is ±2% of reading plus 0.01 NTU from 0 to 1000 NTU, ±5% from 1000 to 4000 NTU, and ±10% from 4000 to 10000 NTU (Ratio on). Includes oiling cloth. Complies with CE, KC, RCM standards and EPA Method 180.1. Suitable for water clarity testing in laboratory and field applications
Turbidity meter for measuring water clarity by detecting suspended particles. Range 0 to 700 NTU/FNU/TE/F/FTU with accuracy ±2% plus 0.01 NTU from 0 to 40 NTU. Includes dust cover. Used in water quality analysis for drinking water, wastewater, and industrial process monitoring
HACH
Turbidity meter for measuring water clarity by detecting suspended particles. Range 0 to 700 NTU/FNU/TE/F/FTU with accuracy ±2% plus 0.01 NTU from 0 to 40 NTU. Includes dust cover. Used in water quality analysis for drinking water, wastewater, and industrial process monitoring
Turbidity meter for measuring suspended particles in liquids, with a range of 0 to 175 EBC and accuracy of +/-2% plus 0.01 NTU from 0 to 40 NTU. Includes power supply. Commonly used in water treatment and industrial process monitoring
HACH
Turbidity meter for measuring suspended particles in liquids, with a range of 0 to 175 EBC and accuracy of +/-2% plus 0.01 NTU from 0 to 40 NTU. Includes power supply. Commonly used in water treatment and industrial process monitoring
Turbidity meter with a measurement range of 0 to 10000 NTU. Accuracy is ±2% of reading plus 0.01 FNU/NTU from 0 to 1000 FNU/NTU. Includes power cord. Used for measuring water clarity in applications such as drinking water treatment, wastewater monitoring, and industrial process control
HACH
Turbidity meter with a measurement range of 0 to 10000 NTU. Accuracy is ±2% of reading plus 0.01 FNU/NTU from 0 to 1000 FNU/NTU. Includes power cord. Used for measuring water clarity in applications such as drinking water treatment, wastewater monitoring, and industrial process control
Turbidity meter with Flow-Thru Head, Tygon Tubing, and USB Cable. CE-marked Type AB/Vial Replacement Tool for measuring water clarity in industrial and environmental applications
HACH
Turbidity meter with Flow-Thru Head, Tygon Tubing, and USB Cable. CE-marked Type AB/Vial Replacement Tool for measuring water clarity in industrial and environmental applications
Turbidity meter for measuring water clarity in the range of 0 to 1000 NTU. Provides accuracy of +/-2% of reading plus stray light. Includes power module. Suitable for field or laboratory use in water quality testing
HACH
Turbidity meter for measuring water clarity in the range of 0 to 1000 NTU. Provides accuracy of +/-2% of reading plus stray light. Includes power module. Suitable for field or laboratory use in water quality testing