We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

HACH Electrode: LZW9655AP.97.02, Fluoride, 0.02 mg/L to 20000 mg/L F-, 1 m Cable Lg - Ion Selective Electrodes
HACHIon Selective Electrodes

HACH Electrode: LZW9655AP.97.02, Fluoride, 0.02 mg/L to 20000 mg/L F-, 1 m Cable Lg

The HACH Electrode LZW9655AP.97.02 is an Ion Selective Electrode for measuring fluoride, with a range of 0.02 mg/L to 20000 mg/L F-. It features a Porous Annular PTFE junction, epoxy body, and BNC connection with a 1…

SKU 3G-OTH-375753

Brand
HACH
Item
Electrode: LZW9655AP.97.02, Fluoride, 0.02 mg/L to 20000 mg/L F-, 1 m Cable Lg
Category
Ion Selective Electrodes
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

HACH
Manufacturer Part Number
LZW9655AP.97.02
Type
Fluoride, 0.02 mg/L to 20000 mg/L F-, BNC
Material
Epoxy
Range
0.02 mg/L to 20000 mg/L F-
Cable Lg
1 m
Junction
Porous Annular PTFE
Product Type
Electrode
Connection Type
BNC
Test Parameters
Fluoride
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HACH Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HACH Electrode LZW9655AP.97.02 is an Ion Selective Electrode for measuring fluoride, with a range of 0.02 mg/L to 20000 mg/L F-. It features a Porous Annular PTFE junction, epoxy body, and BNC connection with a 1 m cable.

Used in

Common applications for HACH
Municipal water treatment — HACH PHC20101 IntelliCAL pH electrode for pH monitoring in distribution systems
Industrial wastewater — HACH Chloride Test Kit (2438600) for chlorine residual analysis in effluent
Laboratory analysis — HACH Buffer Standard Solution S11M005 for calibrating pH meters in quality control labs
Environmental field testing — HACH Chemical Test Strips (2793828) for rapid water quality screening
Process water monitoring — HACH Probe LZW5056.97.0002 for ORP measurement in cooling towers
Wastewater treatment — HACH Water Quality Test Kit (2182000) for nitrite monitoring in biological treatment processes

HACH Products

3G Electric supplies HACH ion selective electrodes. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from HACH

View all HACH parts
HACH Electrode: ISENO318103, Nitrate, 0.1 mg/L (7 x 10-6M) to 14 g/L (1 M) NO3-N, 3 m Cable Lg. Key specifications — Manufacturer Part Number: ISENO318103; Product Type: Electrode; Junction: Double; Test Parameters: Nitrate; Material: Plastic; Range: 0.1 mg/L (7 x 10-6M) to 14 g/L (1 M) NO3-N.
HACH
HACH Electrode: ISENO318103, Nitrate, 0.1 mg/L (7 x 10-6M) to 14 g/L (1 M) NO3-N, 3 m Cable Lg. Key specifications — Manufacturer Part Number: ISENO318103; Product Type: Electrode; Junction: Double; Test Parameters: Nitrate; Material: Plastic; Range: 0.1 mg/L (7 x 10-6M) to 14 g/L (1 M) NO3-N.
HACH Electrode: ISEF12101, Fluoride, 0.01 mg/L (5 x 10-7M) to 19 g/L (1 M) F⁻, 1 m Cable Lg. Key specifications — Manufacturer Part Number: ISEF12101; Product Type: Electrode; Junction: Annular PTFE; Test Parameters: Fluoride; Material: Plastic; Range: 0.01 mg/L (5 x 10-7M) to 19 g/L (1 M) F⁻.
HACH
HACH Electrode: ISEF12101, Fluoride, 0.01 mg/L (5 x 10-7M) to 19 g/L (1 M) F⁻, 1 m Cable Lg. Key specifications — Manufacturer Part Number: ISEF12101; Product Type: Electrode; Junction: Annular PTFE; Test Parameters: Fluoride; Material: Plastic; Range: 0.01 mg/L (5 x 10-7M) to 19 g/L (1 M) F⁻.
HACH Electrode: LZW9652.97.0002, Chloride, 1 mg/L (3 x 10-6M) to 35500 mg/L (1 M) Cl-, 1 m Cable Lg. Key specifications — Manufacturer Part Number: LZW9652.97.0002; Product Type: Electrode; Connection Type: BNC; Test Parameters: Chloride; Material: Epoxy; Range: 1 mg/L (3 x 10-6M) to 35500 mg/L (1 M) Cl-.
HACH
HACH Electrode: LZW9652.97.0002, Chloride, 1 mg/L (3 x 10-6M) to 35500 mg/L (1 M) Cl-, 1 m Cable Lg. Key specifications — Manufacturer Part Number: LZW9652.97.0002; Product Type: Electrode; Connection Type: BNC; Test Parameters: Chloride; Material: Epoxy; Range: 1 mg/L (3 x 10-6M) to 35500 mg/L (1 M) Cl-.
HACH Electrode: LZW9655C.97.002, Fluoride, 0.01 to 19000, 1 m Cable Lg, BNC, Porous Annular PTFE. Key specifications — Manufacturer Part Number: LZW9655C.97.002; Product Type: Electrode; Junction: Porous Annular PTFE; Connection Type: BNC; Test Parameters: Fluoride; Material: Epoxy; Range: 0.01 to 19000.
HACH
HACH Electrode: LZW9655C.97.002, Fluoride, 0.01 to 19000, 1 m Cable Lg, BNC, Porous Annular PTFE. Key specifications — Manufacturer Part Number: LZW9655C.97.002; Product Type: Electrode; Junction: Porous Annular PTFE; Connection Type: BNC; Test Parameters: Fluoride; Material: Epoxy; Range: 0.01 to 19000.
HACH Electrode: LZW9662C.97.002, Nitrate, 0.1 to 14000, 1 m Cable Lg, BNC, Porous Annular PTFE. Key specifications — Manufacturer Part Number: LZW9662C.97.002; Product Type: Electrode; Junction: Porous Annular PTFE; Connection Type: BNC; Test Parameters: Nitrate; Material: PVC; Range: 0.1 to 14000.
HACH
HACH Electrode: LZW9662C.97.002, Nitrate, 0.1 to 14000, 1 m Cable Lg, BNC, Porous Annular PTFE. Key specifications — Manufacturer Part Number: LZW9662C.97.002; Product Type: Electrode; Junction: Porous Annular PTFE; Connection Type: BNC; Test Parameters: Nitrate; Material: PVC; Range: 0.1 to 14000.
HACH Electrode: ISENH3181AP, Ammonia, 0.01 mg/L (5 x 10-7M) to 14 g/L (1 M), 1 m Cable Lg. Key specifications — Manufacturer Part Number: ISENH3181AP; Product Type: Electrode; Junction: Double Annular; Test Parameters: Ammonia; Material: Epoxy; Range: 0.01 mg/L (5 x 10-7M) to 14 g/L (1 M).
HACH
HACH Electrode: ISENH3181AP, Ammonia, 0.01 mg/L (5 x 10-7M) to 14 g/L (1 M), 1 m Cable Lg. Key specifications — Manufacturer Part Number: ISENH3181AP; Product Type: Electrode; Junction: Double Annular; Test Parameters: Ammonia; Material: Epoxy; Range: 0.01 mg/L (5 x 10-7M) to 14 g/L (1 M).
HACH Electrode: ISEF121AP, Fluoride, 0.01 mg/L to 19 g/L, 1 m Cable Lg, Annular PTFE. Key specifications — Manufacturer Part Number: ISEF121AP; Product Type: Electrode; Junction: Annular PTFE; Test Parameters: Fluoride; Material: Epoxy; Range: 0.01 mg/L to 19 g/L.
HACH
HACH Electrode: ISEF121AP, Fluoride, 0.01 mg/L to 19 g/L, 1 m Cable Lg, Annular PTFE. Key specifications — Manufacturer Part Number: ISEF121AP; Product Type: Electrode; Junction: Annular PTFE; Test Parameters: Fluoride; Material: Epoxy; Range: 0.01 mg/L to 19 g/L.
HACH Electrode: ISENH4181AP, Ammonium, 0.018 mg/L (10-6M) to 9 g/L (0.5 M) NH4-N, 1 m Cable Lg. Key specifications — Manufacturer Part Number: ISENH4181AP; Product Type: Electrode; Junction: Double; Test Parameters: Ammonium; Material: Epoxy; Range: 0.018 mg/L (10-6M) to 9 g/L (0.5 M) NH4-N.
HACH
HACH Electrode: ISENH4181AP, Ammonium, 0.018 mg/L (10-6M) to 9 g/L (0.5 M) NH4-N, 1 m Cable Lg. Key specifications — Manufacturer Part Number: ISENH4181AP; Product Type: Electrode; Junction: Double; Test Parameters: Ammonium; Material: Epoxy; Range: 0.018 mg/L (10-6M) to 9 g/L (0.5 M) NH4-N.