We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

The FBR GM X5/2 TC is a dual fuel gas/light oil burner designed for industrial heating applications. Operating at 2 stages with thermal power output of 64.5/130–300 Mcal/h and maximum electrical power of 350 kW, it…

SKU 3G-FBR-00183

Also listed as: 00435741 · 004357 41 · 004357-41

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
30 kg
stage
2 stages
fuel type
Dual fuel gas/light oil
nozzle mm
250
fan motor w
450
power kw max
350
power kw min
75
ip protection
IP 40
noisiness dba
68-72
pump motor kw
180
gas consumption
7.5/15.2-35
electrical supply
1
power supply info
1N~230V 50Hz
current absorption a
0.5
thermal power mcal h
64.5/130-300
nominal electric power w
600
max combustion air temp c
50

Datasheet Content

DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073572_A_en GM X5/2 Dual fuel gas/light-oil burners at 2 stages. Composed by: die-cast aluminium body, high pressurisation air blower, protection cover with noise reduction plate and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train complete of: multiblock valve A class (1st stage + 2nd stage slow opening + safety), minimum gas pressure switch and stabiliser filter. Complete of flange and gasket for installation on generator, two nozzles, flexible pipes and line filter, plug/socket 7 poles. Fig. GM X5/2 TC GM X5/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073572_A_en TECHNICAL DATA MODEL GM X5/2 Thermal power min. 1°st / min. 2°st - max. 2°st * [Mcal/h] 64.5/130-300 Thermal power min. 1°st / min. 2°st - max. 2°st * [kW] 75/151-350 Gas flow G20 (NATURAL GAS) min. 1°st/min. 2°st - max. 2°st * [Nm³/h] 7.5/15.2-35 Gas flow G31 (L.P.G.) min. 1°st / min. 2°st - max. 2°st * [Nm³/h] 3/5.8-13.5 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R)B I3B/P,I3+,I3P,I3B,I3R Minimum pressure gas train D1" - S NATURAL GAS/LPG ** [mbar] 41.9/23 Minimum pressure gas train D1"1/4 - S NATURAL GAS/LPG ** [mbar] 23.7-16 Minimum pressure gas train D1"1/2 - S NATURAL GAS/LPG ** [mbar] 12.7-11.2 Maximum pressure at the entry of valves (Pe. max) 360 mbar LIGHT-OIL flow min. 1°st / min. 2°st - max. 2°st * [kg/h] 6.5/13-30 Fuel: LIGHT-OIL 1,5°E at 20°C= 6,2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) 2 stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 50 Nominal electric power [W] 600 Fan motor [W] 450 Nominal absorption fan motor [A] 3.9 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness *** min. - max. [dB(A)] 68-72 Burner weight [kg] 30 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). GM X5/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073572_A_en OPERATING RANGE DIAGRAM [mbar] 9 8 7 6 5 4 3 2 1 0 0 50 100 150 200 250 300 350 400 [kW] Fig. X = Thermal power Y = pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. GM X5/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073572_A_en DIMENSIONS [MM] H S G I D RD R1 F A B TC - TL * E R2 R4 R3 C Fig. Dimensions MODEL A B C D E F G H I S R1 R2 R3 R4 RD Gas train weight GM X5/2 210 215 465 138 100 310 95 200 200 20 210 300 360 380 Rp1 6 kg TC-TL*: see chapter "FLAME TUBE LENGTH" BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. Boiler plate MODEL L min L* L max M N min N* N max GM X5/2 mm 205 220 226 M10 140 150 180 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** GM X5/2 mm 250 335 ** For different flame tube lengths, please contact our Technical-Sales Department. GM X5/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073572_A_en PRODUCT SPECIFICATION SHORT DESCRIPTION Dual fuel gas/light-oil burners at 2 stages. DETAILED SPECIFICATION Dual fuel gas/light-oil burners at 2 stages, composed by: • Die-cast aluminum body; • High pressurization air blower; • Combustion head with adjustment at high performance and elevated flame stability equipped with blast tube and flame disc; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Manual switch for the fuel selection gas/light-oil; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Equipped with gas train with multiblock valve A class (1st stage + 2nd stage slow opening + safety), minimum gas pressure switch and stabiliser filter; • Servomotor for air shutter and for the consent of the 2nd stage gas valve; • UV probe for flame detection; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • 2009/142/CE Directive GAS; • Reference rules: EN676 (gas) - EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible pipes; • Line filter; • Isomart gasket; • Two nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise protection; • Antivibration couplings; • Handle gas taps. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. GM X5/2

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR GM X5/2 TC is a dual fuel gas/light oil burner designed for industrial heating applications. Operating at 2 stages with thermal power output of 64.5/130–300 Mcal/h and maximum electrical power of 350 kW, it delivers efficient combustion control. The unit features IP 40 protection and operates at 68–72 dBA, suitable for medium to large-scale industrial installations.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR GM X5/2 TC burner in the Philippines?

3G Electric Philippines sources and delivers the FBR GM X5/2 TC burner to Manila and Quezon City. We handle Bureau of Customs documentation, logistics coordination, and PHP invoicing. Contact us for availability and lead times on this dual fuel unit.

What is the lead time for the FBR GM X5/2 TC dual fuel burner?

Lead time depends on current stock and origin availability. The FBR GM X5/2 TC is available to order through 3G Electric Philippines. We manage all import logistics and customs clearance to your site. Request a quote for specific delivery schedules.

What are the thermal power and electrical specifications of the FBR GM X5/2 TC?

The FBR GM X5/2 TC delivers 64.5–300 Mcal/h across 2 stages, with maximum electrical power of 350 kW and minimum 75 kW. It operates on 1N~230V 50Hz, draws 0.5 A, and features IP 40 protection. Fuel consumption: 7.5/15.2–35 Nm³/h gas; nozzle capacity 250 mm.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GM X5/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
GM X5/2 TL | Variant: variant_2 | Subgroup: Burner
X GM X1 TC | Variant: variant_2 | Subgroup: Burner
FBR
X GM X1 TC | Variant: variant_2 | Subgroup: Burner
X GM X0 TC | Variant: variant_2 | Subgroup: Burner
FBR
X GM X0 TC | Variant: variant_2 | Subgroup: Burner
X GM X1 TL | Variant: variant_2 | Subgroup: Burner
FBR
X GM X1 TL | Variant: variant_2 | Subgroup: Burner
GM X0 TL | Variant: variant_2 | Subgroup: Burner
FBR
GM X0 TL | Variant: variant_2 | Subgroup: Burner
GM X4 TC | Variant: variant_2 | Subgroup: Burner
FBR
GM X4 TC | Variant: variant_2 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL