GE Molded Case Circuit Breaker: 45 A Amps, 14kA at 277V AC, Fixed, Lug
The GE TEY-Frame Molded Case Circuit Breaker (MPN TEY145) is a 45 A, fixed instantaneous-trip device with a maximum AIR rating of 14kA at 277V AC. It features lug terminal connections and supports any phase…
SKU 3G-OTH-23064
Need installation or engineering help?
Ask a question
Product Description
The GE TEY-Frame Molded Case Circuit Breaker (MPN TEY145) is a 45 A, fixed instantaneous-trip device with a maximum AIR rating of 14kA at 277V AC. It features lug terminal connections and supports any phase connection. This product is part of the TEY series from GE.
Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.
Frequently Asked Questions
What is the GE TEY145 molded case circuit breaker used for?
The GE TEY145 is a 45 A molded case circuit breaker used for overcurrent protection in industrial and commercial electrical distribution systems. It is suitable for branch-circuit protection in panelboards, switchboards, and motor control centers where a fixed instantaneous trip and lug terminals are required.
What are the specifications of the GE TEY145 circuit breaker?
The GE TEY145 is a TEY-series molded case circuit breaker rated 45 A with a maximum AIR rating of 14kA at 277V AC. It features a fixed instantaneous trip, lug terminal connections, and supports any phase connection. The manufacturer part number is TEY145.
Where to buy the GE TEY145 circuit breaker worldwide?
3G Electric supplies the GE TEY145 circuit breaker worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time; we source and deliver this GE breaker to any international destination.
How to select the right GE TEY-frame circuit breaker for my application?
To select the correct GE TEY-frame breaker, verify the continuous current rating (e.g., 45 A for the TEY145), the maximum available fault current (14kA at 277V AC), and the required terminal type (lug). Ensure the instantaneous trip setting matches your load's inrush characteristics. Consult a licensed electrician for code compliance.
Used in
Common applications for GEGE Products
3G Electric supplies GE tey-frame ge molded case circuit breakers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.