GE Molded Case Circuit Breaker: 50 A Amps, 35kA at 277/480V AC, Fixed, Lug
The GE TEY-Frame Molded Case Circuit Breaker (MPN TEYH2050B) is a 50 A, fixed instantaneous trip device with a maximum AIR rating of 35kA at 277/480V AC. It features lug terminal connections and ABC phase connection…
SKU 3G-OTH-23751
Need installation or engineering help?
Ask a question
Product Description
The GE TEY-Frame Molded Case Circuit Breaker (MPN TEYH2050B) is a 50 A, fixed instantaneous trip device with a maximum AIR rating of 35kA at 277/480V AC. It features lug terminal connections and ABC phase connection, part of the TEY series.
Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.
Frequently Asked Questions
What is the GE TEYH2050B molded case circuit breaker used for?
The GE TEYH2050B is a 50 A molded case circuit breaker used for overcurrent protection in industrial and commercial electrical distribution systems. It is designed for fixed instantaneous trip applications at 277/480V AC, with a 35kA interrupting rating, making it suitable for branch circuit protection in panelboards and switchboards.
What are the specifications of the GE TEYH2050B circuit breaker?
The GE TEYH2050B is a TEY-Frame molded case circuit breaker rated 50 A with a maximum AIR rating of 35kA at 277/480V AC. It features fixed instantaneous trip, lug terminal connections, and ABC phase connection. The manufacturer part number is TEYH2050B, part of the GE TEY series.
Where to buy the GE TEYH2050B circuit breaker worldwide?
3G Electric supplies the GE TEYH2050B molded case circuit breaker to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. As a global industrial solutions provider, we source and deliver genuine GE electrical components, including the TEY series, to support your project needs.
How to select the correct GE TEYH2050B circuit breaker for an application?
To select the GE TEYH2050B, verify your system voltage (277/480V AC), required ampacity (50 A), and interrupting capacity (35kA minimum). Ensure the fixed instantaneous trip and lug terminal connections match your panelboard or switchboard. Confirm phase connection (ABC) and frame size (TEY) compatibility with your existing GE equipment.
Used in
Common applications for GEGE Products
3G Electric supplies GE tey-frame ge molded case circuit breakers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.















