We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

GASTEC Detector Tube: COS, Gas Detection Tube, Carbonyl Sulfide ( COS ), With Pump - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Detector Tube: COS, Gas Detection Tube, Carbonyl Sulfide ( COS ), With Pump

The GASTEC Detector Tube: COS (MPN 21LA) is a gas detection tube for carbonyl sulfide, designed for use with GASTEC GV-100 and GV-110 pumps. Each pack contains 5 calibrated tubes with a measurement range of 2 to 125 ppm.

SKU 3G-OTH-553122

Brand
GASTEC
Item
Detector Tube: COS, Gas Detection Tube, Carbonyl Sulfide
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

GASTEC
Manufacturer Part Number
21LA
Type
Gas Detection Tube, Carbonyl Sulfide ( COS ), With Pump, Calibrated, 5 PK
Gas Detected
Carbonyl Sulfide
Measurement Range
2 to 125 ppm
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube: COS (MPN 21LA) is a gas detection tube for carbonyl sulfide, designed for use with GASTEC GV-100 and GV-110 pumps. Each pack contains 5 calibrated tubes with a measurement range of 2 to 125 ppm.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the GASTEC 21LA detector tube used for?

The GASTEC 21LA detector tube is used to measure carbonyl sulfide (COS) concentrations in industrial environments. It is designed for use with GASTEC GV-100 and GV-110 pumps, providing calibrated readings from 2 to 125 ppm for safety monitoring.

What are the specifications of the GASTEC 21LA gas detection tube?

The GASTEC 21LA detects carbonyl sulfide (COS) with a measurement range of 2 to 125 ppm. Each pack contains 5 calibrated tubes for use with GASTEC GV-100 and GV-110 pumps. The manufacturer part number is 21LA.

Where to buy GASTEC 21LA detector tubes worldwide?

3G Electric supplies GASTEC 21LA detector tubes worldwide. As a global industrial solutions provider, we handle full logistics and customs clearance to deliver these calibrated COS detection tubes to your facility, regardless of location.

How to use the GASTEC 21LA tube with a GV-100 pump?

Break both tips of the GASTEC 21LA tube, insert it into the GV-100 pump inlet, and pull the handle fully to draw a sample. Follow the pump stroke count and read the concentration directly from the tube scale. Always refer to the GASTEC manual for precise steps.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC Detector Tube: CH2O, Gas Detection Tube, Formaldehyde ( CH2O ), With Pump, 6,000 mL, 10 PK (MPN 91P). Key specifications — Gas Detected: Formaldehyde; Measurement Range: 0.02 to 1.44 ppm.
GASTEC
GASTEC Detector Tube: CH2O, Gas Detection Tube, Formaldehyde ( CH2O ), With Pump, 6,000 mL, 10 PK (MPN 91P). Key specifications — Gas Detected: Formaldehyde; Measurement Range: 0.02 to 1.44 ppm.
GASTEC Detector Tube: H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), With Pump, 10 PK (MPN 4LK). Key specifications — Gas Detected: Hydrogen Sulphide; Measurement Range: 1 to 40 ppm.
GASTEC
GASTEC Detector Tube: H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), With Pump, 10 PK (MPN 4LK). Key specifications — Gas Detected: Hydrogen Sulphide; Measurement Range: 1 to 40 ppm.
GASTEC Detector Tube: SO2, Gas Detection Tube, Sulfur Dioxide ( SO2 ), With Pump, Calibrated, 10 PK (MPN 5DH). Key specifications — Gas Detected: Sulfur Dioxide; Measurement Range: 10 to 600 ppm.
GASTEC
GASTEC Detector Tube: SO2, Gas Detection Tube, Sulfur Dioxide ( SO2 ), With Pump, Calibrated, 10 PK (MPN 5DH). Key specifications — Gas Detected: Sulfur Dioxide; Measurement Range: 10 to 600 ppm.
GASTEC Detector Tube: C2H6S, Gas Detection Tube, Ethyl Mercaptan ( C2H6S ), With Pump, 10 PK (MPN 72L). Key specifications — Gas Detected: Ethyl Mercaptan; Measurement Range: 0.2 to 75 ppm.
GASTEC
GASTEC Detector Tube: C2H6S, Gas Detection Tube, Ethyl Mercaptan ( C2H6S ), With Pump, 10 PK (MPN 72L). Key specifications — Gas Detected: Ethyl Mercaptan; Measurement Range: 0.2 to 75 ppm.
GASTEC Detector Tube: GASTEC GV-100, HCN, Gas Detection Tube, Hydrogen Cyanide ( HCN ), 10 PK (MPN 12L). Key specifications — Gas Detected: Hydrogen Cyanide; Measurement Range: 0.5 to 150 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, HCN, Gas Detection Tube, Hydrogen Cyanide ( HCN ), 10 PK (MPN 12L). Key specifications — Gas Detected: Hydrogen Cyanide; Measurement Range: 0.5 to 150 ppm.
GASTEC Detector Tube: PH3, Gas Detection Tube, Phosphine ( PH3 ), With Pump, 2.5 to 1,000 ppm, 10 PK (MPN 7J). Key specifications — Gas Detected: Phosphine; Measurement Range: 2.5 to 1,000 ppm.
GASTEC
GASTEC Detector Tube: PH3, Gas Detection Tube, Phosphine ( PH3 ), With Pump, 2.5 to 1,000 ppm, 10 PK (MPN 7J). Key specifications — Gas Detected: Phosphine; Measurement Range: 2.5 to 1,000 ppm.
GASTEC Detector Tube: C6H6, Gas Detection Tube, Benzene ( C6H6 ), With Pump, 0.2 to 66 ppm, 5 PK (MPN 121SP). Key specifications — Gas Detected: Benzene; Measurement Range: 0.2 to 66 ppm.
GASTEC
GASTEC Detector Tube: C6H6, Gas Detection Tube, Benzene ( C6H6 ), With Pump, 0.2 to 66 ppm, 5 PK (MPN 121SP). Key specifications — Gas Detected: Benzene; Measurement Range: 0.2 to 66 ppm.
GASTEC Detector Tube: H2O, Gas Detection Tube, Water Vapor ( H2O ), With Pump, 0.05 to 2 mg/L, 10 PK (MPN 6L). Key specifications — Gas Detected: Water Vapor; Measurement Range: 0.05 to 2 mg/L.
GASTEC
GASTEC Detector Tube: H2O, Gas Detection Tube, Water Vapor ( H2O ), With Pump, 0.05 to 2 mg/L, 10 PK (MPN 6L). Key specifications — Gas Detected: Water Vapor; Measurement Range: 0.05 to 2 mg/L.