We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

GASTEC Detector Tube: GASTEC GV-100, SO2, Gas Detection Tube, Sulphur Dioxide ( SO2 ) - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Detector Tube: GASTEC GV-100, SO2, Gas Detection Tube, Sulphur Dioxide ( SO2 )

The GASTEC Detector Tube (MPN 5L) is a sulphur dioxide (SO2) gas detection tube, supplied in a 10-pack for use with GASTEC GV-100 and GV-110 pumps. It measures SO2 concentrations from 1.25 to 200 ppm, enabling…

SKU 3G-OTH-553235

Brand
GASTEC
Item
Detector Tube: GASTEC GV-100, SO2, Gas Detection Tube, Sulphur Dioxide
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

GASTEC
Manufacturer Part Number
5L
Type
SO2, Gas Detection Tube, Sulphur Dioxide ( SO2 ), 10 PK
Gas Detected
Sulphur Dioxide
Measurement Range
1.25 to 200 ppm
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube (MPN 5L) is a sulphur dioxide (SO2) gas detection tube, supplied in a 10-pack for use with GASTEC GV-100 and GV-110 pumps. It measures SO2 concentrations from 1.25 to 200 ppm, enabling precise field sampling of this specific gas.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the GASTEC Detector Tube 5L used for?

The GASTEC Detector Tube 5L is used for field detection and measurement of sulphur dioxide (SO2) gas concentrations. It works with GASTEC GV-100 and GV-110 pumps to sample air in industrial environments, helping plant engineers and safety personnel monitor SO2 exposure in applications such as combustion processes, chemical plants, and HVAC systems.

What are the specifications of the GASTEC Detector Tube 5L?

The GASTEC Detector Tube 5L detects sulphur dioxide (SO2) with a measurement range of 1.25 to 200 ppm. It is supplied in a 10-pack and is designed for use with GASTEC GV-100 and GV-110 pumps. The manufacturer part number is 5L. This tube enables precise, on-site gas sampling for industrial safety and compliance.

Where to buy GASTEC Detector Tube 5L worldwide?

3G Electric supplies the GASTEC Detector Tube 5L to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery for international orders. Contact our team to source this SO2 detection tube for your facility, regardless of your location.

How to use the GASTEC Detector Tube 5L with a GV-100 pump?

To use the GASTEC Detector Tube 5L, break both tips of the tube using the tip breaker on the GV-100 or GV-110 pump. Insert the tube into the pump inlet with the arrow pointing toward the pump. Pull the handle to draw a sample according to the pump stroke instructions. Read the SO2 concentration directly from the tube scale after the recommended number of strokes.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC Detector Tube: GASTEC GV-100, Cl2, Gas Detection Tube, Chlorine ( Cl2 ), With Pump, 10 PK (MPN 8H). Key specifications — Gas Detected: Chlorine; Measurement Range: 25 to 1,000 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, Cl2, Gas Detection Tube, Chlorine ( Cl2 ), With Pump, 10 PK (MPN 8H). Key specifications — Gas Detected: Chlorine; Measurement Range: 25 to 1,000 ppm.
GASTEC Detector Tube: GASTEC GV-100, Gas Detection Tube, Hydrocarbon, With Pump, Hydrocarbon, 10 PK (MPN 105). Key specifications — Gas Detected: Hydrocarbon; Measurement Range: 100 to 3,000 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, Gas Detection Tube, Hydrocarbon, With Pump, Hydrocarbon, 10 PK (MPN 105). Key specifications — Gas Detected: Hydrocarbon; Measurement Range: 100 to 3,000 ppm.
GASTEC Detector Tube: GASTEC GV-100, C2Cl4, Gas Detection Tube, Tetrachloroethylene ( C2Cl4 ), 10 PK (MPN 133L). Key specifications — Gas Detected: Tetrachloroethylene; Measurement Range: 1 to 75 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C2Cl4, Gas Detection Tube, Tetrachloroethylene ( C2Cl4 ), 10 PK (MPN 133L). Key specifications — Gas Detected: Tetrachloroethylene; Measurement Range: 1 to 75 ppm.
GASTEC Detector Tube: GASTEC GV-100, Cl2, Gas Detection Tube, Chlorine ( Cl2 ), With Pump, 10 PK (MPN 8LA). Key specifications — Gas Detected: Chlorine; Measurement Range: 0.1 to 16 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, Cl2, Gas Detection Tube, Chlorine ( Cl2 ), With Pump, 10 PK (MPN 8LA). Key specifications — Gas Detected: Chlorine; Measurement Range: 0.1 to 16 ppm.
GASTEC Detector Tube: CH4S, Gas Detection Tube, Methyl Mercaptan ( CH4S ), With Pump, 10 PK (MPN 71). Key specifications — Gas Detected: Methyl Mercaptan; Measurement Range: 0.25 to 140 ppm.
GASTEC
GASTEC Detector Tube: CH4S, Gas Detection Tube, Methyl Mercaptan ( CH4S ), With Pump, 10 PK (MPN 71). Key specifications — Gas Detected: Methyl Mercaptan; Measurement Range: 0.25 to 140 ppm.
GASTEC Detector Tube: GASTEC GV-100, O2, Gas Detection Tube, Oxygen ( O2 ), With Pump, Oxygen, 5 PK (MPN 31B). Key specifications — Gas Detected: Oxygen; Measurement Range: 3 to 24%.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, O2, Gas Detection Tube, Oxygen ( O2 ), With Pump, Oxygen, 5 PK (MPN 31B). Key specifications — Gas Detected: Oxygen; Measurement Range: 3 to 24%.
GASTEC Detector Tube: H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), With Pump, 10 PK (MPN 4HT). Key specifications — Gas Detected: Hydrogen Sulphide; Measurement Range: 1 to 40%.
GASTEC
GASTEC Detector Tube: H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), With Pump, 10 PK (MPN 4HT). Key specifications — Gas Detected: Hydrogen Sulphide; Measurement Range: 1 to 40%.
GASTEC Detector Tube: H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), With Pump, 10 PK (MPN 4HP). Key specifications — Gas Detected: Hydrogen Sulphide; Measurement Range: 0.25 to 20% vol.
GASTEC
GASTEC Detector Tube: H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), With Pump, 10 PK (MPN 4HP). Key specifications — Gas Detected: Hydrogen Sulphide; Measurement Range: 0.25 to 20% vol.