We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

GASTEC Detector Tube: GASTEC GV-100, PH3, Gas Detection Tube, Phosphine ( PH3 ) - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Detector Tube: GASTEC GV-100, PH3, Gas Detection Tube, Phosphine ( PH3 )

The GASTEC Detector Tube (MPN 7LA) is a phosphine (PH3) gas detection tube for use with GASTEC GV-100 and GV-110 pumps, supplied in a 10-pack. It detects phosphine across a measurement range of 0.05 to 9.8 ppm…

SKU 3G-OTH-553187

Brand
GASTEC
Item
Detector Tube: GASTEC GV-100, PH3, Gas Detection Tube, Phosphine
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

GASTEC
Manufacturer Part Number
7LA
Type
PH3, Gas Detection Tube, Phosphine ( PH3 ), With Pump, 10 PK
Gas Detected
Phosphine
Measurement Range
0.05 to 9.8 ppm
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube (MPN 7LA) is a phosphine (PH3) gas detection tube for use with GASTEC GV-100 and GV-110 pumps, supplied in a 10-pack. It detects phosphine across a measurement range of 0.05 to 9.8 ppm, enabling precise field sampling for industrial safety applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the GASTEC 7LA detector tube used for?

The GASTEC 7LA detector tube is used for measuring phosphine (PH3) gas concentrations in industrial safety applications. It works with GASTEC GV-100 and GV-110 pumps to detect phosphine from 0.05 to 9.8 ppm, enabling precise field sampling for fumigation monitoring or workplace exposure checks.

What are the specifications of the GASTEC 7LA phosphine tube?

The GASTEC 7LA tube detects phosphine (PH3) gas with a measurement range of 0.05 to 9.8 ppm. It is supplied in a 10-pack and is designed for use with GASTEC GV-100 and GV-110 pumps. The manufacturer part number is 7LA.

Where to buy GASTEC 7LA detector tubes worldwide?

3G Electric supplies GASTEC 7LA phosphine detector tubes worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this 10-pack of tubes for GV-100 and GV-110 pumps.

How to use the GASTEC 7LA tube with a GV-100 pump?

To use the GASTEC 7LA tube, break both tips off the tube using the tip breaker on the GV-100 pump. Insert the tube into the pump inlet with the arrow pointing toward the pump. Pull the handle to draw a sample; follow the pump instructions for stroke count. Read the concentration directly from the tube scale.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC Detector Tube: H2O, Gas Detection Tube, Water Vapor ( H2O ), With Pump, Water Vapor, 10 PK (MPN 6LP). Key specifications — Gas Detected: Water Vapor; Measurement Range: 3 to 100 lb/mmcf.
GASTEC
GASTEC Detector Tube: H2O, Gas Detection Tube, Water Vapor ( H2O ), With Pump, Water Vapor, 10 PK (MPN 6LP). Key specifications — Gas Detected: Water Vapor; Measurement Range: 3 to 100 lb/mmcf.
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), 104°F Max Op Temp [NEW], 10 PK (MPN 1D). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 1.04 to 2,000 ppm.
GASTEC
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), 104°F Max Op Temp [NEW], 10 PK (MPN 1D). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 1.04 to 2,000 ppm.
GASTEC Detector Tube: PH3, Gas Detection Tube, Phosphine ( PH3 ), With Pump, 0.15 to 5 ppm, 10 PK (MPN 7L). Key specifications — Gas Detected: Phosphine; Measurement Range: 0.15 to 5 ppm.
GASTEC
GASTEC Detector Tube: PH3, Gas Detection Tube, Phosphine ( PH3 ), With Pump, 0.15 to 5 ppm, 10 PK (MPN 7L). Key specifications — Gas Detected: Phosphine; Measurement Range: 0.15 to 5 ppm.
GASTEC Detector Tube: GASTEC GV-100, O3, Gas Detection Tube, Ozone ( O3 ), With Pump, Ozone, 10 PK (MPN 18L). Key specifications — Gas Detected: Ozone; Measurement Range: 0.025 to 6 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, O3, Gas Detection Tube, Ozone ( O3 ), With Pump, Ozone, 10 PK (MPN 18L). Key specifications — Gas Detected: Ozone; Measurement Range: 0.025 to 6 ppm.
GASTEC Detector Tube: C2H6S, Gas Detection Tube, Ethyl Mercaptan ( C2H6S ), 2.5 to 30 ppm, 10 PK (MPN 72P). Key specifications — Gas Detected: Ethyl Mercaptan; Measurement Range: 2.5 to 30 ppm.
GASTEC
GASTEC Detector Tube: C2H6S, Gas Detection Tube, Ethyl Mercaptan ( C2H6S ), 2.5 to 30 ppm, 10 PK (MPN 72P). Key specifications — Gas Detected: Ethyl Mercaptan; Measurement Range: 2.5 to 30 ppm.
GASTEC Detector Tube: GASTEC GV-100, Gas Detection Tube, Stoddard Solvent, With Pump, 10 PK (MPN 128). Key specifications — Gas Detected: Stoddard Solvent; Measurement Range: 50 to 8,000 mg/m3.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, Gas Detection Tube, Stoddard Solvent, With Pump, 10 PK (MPN 128). Key specifications — Gas Detected: Stoddard Solvent; Measurement Range: 50 to 8,000 mg/m3.
GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN 3HM). Key specifications — Gas Detected: Ammonia; Measurement Range: 0.05 to 3.52% vol.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN 3HM). Key specifications — Gas Detected: Ammonia; Measurement Range: 0.05 to 3.52% vol.
GASTEC Detector Tube: GASTEC GV-100, C7H8, Gas Detection Tube, Toluene ( C7H8 ), With Pump, 10 PK (MPN 122L). Key specifications — Gas Detected: Toluene; Measurement Range: 1 to 100 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C7H8, Gas Detection Tube, Toluene ( C7H8 ), With Pump, 10 PK (MPN 122L). Key specifications — Gas Detected: Toluene; Measurement Range: 1 to 100 ppm.