We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

GASTEC Detector Tube: GASTEC GV-100, NO/NO2, Gas Detection Tube, With Pump, 2.5 to 200 ppm - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Detector Tube: GASTEC GV-100, NO/NO2, Gas Detection Tube, With Pump, 2.5 to 200 ppm

The GASTEC Detector Tube (GV-100) is a nitrogen dioxide gas detection tube with a measurement range of 2.5 to 200 ppm, supplied in a 5-pack for use with GASTEC GV-100 and GV-110 pumps. This product is part of 3G…

SKU 3G-OTH-553181

Brand
GASTEC
Item
Detector Tube: GASTEC GV-100, NO/NO2, Gas Detection Tube, With Pump, 2.5 to 200 ppm
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

GASTEC
Manufacturer Part Number
10
Type
NO/NO2, Gas Detection Tube, With Pump, 2.5 to 200 ppm, 5 PK
Gas Detected
Nitrogen Dioxide
Measurement Range
2.5 to 200 ppm
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube (GV-100) is a nitrogen dioxide gas detection tube with a measurement range of 2.5 to 200 ppm, supplied in a 5-pack for use with GASTEC GV-100 and GV-110 pumps. This product is part of 3G Electric's broad industrial solutions across 14 departments, with specialist depth in combustion, pumps, and controls as an authorised distributor for brands like GASTEC, ensuring accurate sourcing and support.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the GASTEC GV-100 detector tube used for?

The GASTEC GV-100 detector tube is used to measure nitrogen dioxide (NO/NO2) concentrations in air, with a range of 2.5 to 200 ppm. It is designed for use with GASTEC GV-100 and GV-110 pumps, making it essential for industrial hygiene, environmental monitoring, and combustion exhaust analysis.

What are the specifications of the GASTEC detector tube 10?

The GASTEC detector tube (part number 10) detects nitrogen dioxide gas, with a measurement range of 2.5 to 200 ppm. It is supplied in a 5-pack and requires a GASTEC GV-100 or GV-110 pump for operation. This tube is used for spot-checking NO/NO2 levels in workplace or emission environments.

Where to buy GASTEC detector tubes worldwide?

3G Electric supplies GASTEC detector tubes worldwide, handling full logistics and customs clearance for global delivery. As a specialist in industrial solutions across 14 departments, we source genuine GASTEC tubes like the GV-100 series for nitrogen dioxide detection. Contact us for pricing and lead time to your location.

How to use the GASTEC GV-100 detector tube with a pump?

To use the GASTEC detector tube, break both tips off the tube, insert it into the GASTEC GV-100 or GV-110 pump inlet, and pull the handle to draw a sample. Follow the pump stroke count specified for the tube type. Read the concentration directly from the tube's colorimetric scale. Always refer to the manufacturer's instructions for safe operation.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), With Pump, Calibrated, 10 PK (MPN 1HH). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 1 to 40%.
GASTEC
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), With Pump, Calibrated, 10 PK (MPN 1HH). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 1 to 40%.
GASTEC Detector Tube: GASTEC GV-100, C2H3Cl, Gas Detection Tube, Vinyl Chloride ( C2H3Cl ), 10 PK (MPN 131LB). Key specifications — Gas Detected: Vinyl Chloride; Measurement Range: 0.4 to 70 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C2H3Cl, Gas Detection Tube, Vinyl Chloride ( C2H3Cl ), 10 PK (MPN 131LB). Key specifications — Gas Detected: Vinyl Chloride; Measurement Range: 0.4 to 70 ppm.
GASTEC Detector Tube: CO2, Gas Detection Tube, Carbon Dioxide ( CO2 ), 32°F Min Op Temp [NEW], 10 PK (MPN 2D). Key specifications — Gas Detected: Carbon Dioxide; Measurement Range: 0.02 to 12%.
GASTEC
GASTEC Detector Tube: CO2, Gas Detection Tube, Carbon Dioxide ( CO2 ), 32°F Min Op Temp [NEW], 10 PK (MPN 2D). Key specifications — Gas Detected: Carbon Dioxide; Measurement Range: 0.02 to 12%.
GASTEC Detector Tube: GASTEC GV-100, C4H8O, Gas Detection Tube, Methyl Ethyl Ketone ( C4H8O ), 10 PK (MPN 152). Key specifications — Gas Detected: Methyl Ethyl Ketone; Measurement Range: 0.02 to 0.6%.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C4H8O, Gas Detection Tube, Methyl Ethyl Ketone ( C4H8O ), 10 PK (MPN 152). Key specifications — Gas Detected: Methyl Ethyl Ketone; Measurement Range: 0.02 to 0.6%.
GASTEC Detector Tube: GASTEC GV-100, C2H6O2, Gas Detection Tube, Ethylene Glycol ( C2H6O2 ), 5 PK (MPN 165L). Key specifications — Gas Detected: Ethylene Glycol; Measurement Range: 10 to 100 mg/m3.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C2H6O2, Gas Detection Tube, Ethylene Glycol ( C2H6O2 ), 5 PK (MPN 165L). Key specifications — Gas Detected: Ethylene Glycol; Measurement Range: 10 to 100 mg/m3.
GASTEC Detector Tube: GASTEC GV-100, R・NH2, Gas Detection Tube, Amines ( R・NH2 ), With Pump, 10 PK (MPN 180). Key specifications — Gas Detected: Amines; Measurement Range: 5 to 100 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, R・NH2, Gas Detection Tube, Amines ( R・NH2 ), With Pump, 10 PK (MPN 180). Key specifications — Gas Detected: Amines; Measurement Range: 5 to 100 ppm.
GASTEC Detector Tube: CH2O, Gas Detection Tube, Formaldehyde ( CH2O ), With Pump, Calibrated, 10 PK (MPN 91M). Key specifications — Gas Detected: Formaldehyde; Measurement Range: 8 to 6,400 ppm.
GASTEC
GASTEC Detector Tube: CH2O, Gas Detection Tube, Formaldehyde ( CH2O ), With Pump, Calibrated, 10 PK (MPN 91M). Key specifications — Gas Detected: Formaldehyde; Measurement Range: 8 to 6,400 ppm.
GASTEC Detector Tube: GASTEC GV-100, Gas Detection Tube, Acid, With Pump, 1 min (2 to 40 ppm), 10 PK (MPN 80). Key specifications — Gas Detected: Acid; Measurement Range: 1 to 80 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, Gas Detection Tube, Acid, With Pump, 1 min (2 to 40 ppm), 10 PK (MPN 80). Key specifications — Gas Detected: Acid; Measurement Range: 1 to 80 ppm.