GASTEC Detector Tube: GASTEC GV-100, CH3Br, Gas Detection Tube, Methyl Bromide ( CH3Br ) - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Detector Tube: GASTEC GV-100, CH3Br, Gas Detection Tube, Methyl Bromide ( CH3Br )

The GASTEC Detector Tube (MPN 136L) is a gas detection tube for methyl bromide (CH3Br), supplied in a 5-pack for use with GASTEC GV-100 and GV-110 pumps. It measures methyl bromide concentrations from 2.5 to 200 ppm…

SKU 3G-OTH-553251

Brand
GASTEC
Item
Detector Tube: GASTEC GV-100, CH3Br, Gas Detection Tube, Methyl Bromide
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

GASTEC
Manufacturer Part Number
136L
Type
CH3Br, Gas Detection Tube, Methyl Bromide ( CH3Br ), 5 PK
Gas Detected
Methyl Bromide
Measurement Range
2.5 to 200 ppm
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube (MPN 136L) is a gas detection tube for methyl bromide (CH3Br), supplied in a 5-pack for use with GASTEC GV-100 and GV-110 pumps. It measures methyl bromide concentrations from 2.5 to 200 ppm, enabling precise field detection of this fumigant gas.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the GASTEC 136L detector tube used for?

The GASTEC 136L detector tube is used for field detection of methyl bromide (CH3Br) fumigant gas. It works with GASTEC GV-100 and GV-110 pumps to measure concentrations from 2.5 to 200 ppm, supporting safety in agricultural fumigation and pest control applications.

What are the specifications of the GASTEC 136L detector tube?

The GASTEC 136L detector tube detects methyl bromide (CH3Br) with a measurement range of 2.5 to 200 ppm. It is supplied in a 5-pack and is designed for use with GASTEC GV-100 and GV-110 pumps. The manufacturer part number is 136L.

Where to buy GASTEC 136L detector tubes worldwide?

3G Electric supplies GASTEC 136L detector tubes worldwide. As a global industrial solutions provider, we handle full logistics and customs clearance to deliver genuine GASTEC gas detection tubes to your facility, ensuring compliance with local import requirements.

How to use the GASTEC 136L detector tube with a GV-100 pump?

To use the GASTEC 136L tube, break both tips off the tube, insert it into the GV-100 or GV-110 pump inlet, and pull the handle to draw a sample. Follow the pump stroke count and compare the stain length to the printed scale for methyl bromide concentration from 2.5 to 200 ppm.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC Detector Tube: GASTEC GV-100, C2H4O2, Gas Detection Tube, Acetic Acid ( C2H4O2 ), 10 PK (MPN 81L). Key specifications — Gas Detected: Acetic Acid; Measurement Range: 0.125 to 23 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C2H4O2, Gas Detection Tube, Acetic Acid ( C2H4O2 ), 10 PK (MPN 81L). Key specifications — Gas Detected: Acetic Acid; Measurement Range: 0.125 to 23 ppm.
GASTEC Detector Tube: SO2, Gas Detection Tube, Sulfur Dioxide ( SO2 ), With Pump, Calibrated, 10 PK (MPN 5H). Key specifications — Gas Detected: Sulfur Dioxide; Measurement Range: 0.05 to 8%.
GASTEC
GASTEC Detector Tube: SO2, Gas Detection Tube, Sulfur Dioxide ( SO2 ), With Pump, Calibrated, 10 PK (MPN 5H). Key specifications — Gas Detected: Sulfur Dioxide; Measurement Range: 0.05 to 8%.
GASTEC Detector Tube: SO2, Gas Detection Tube, Sulfur Dioxide ( SO2 ), 32°F Min Op Temp [NEW], 10 PK (MPN 5D). Key specifications — Gas Detected: Sulfur Dioxide; Measurement Range: 0.2 to 100 ppm.
GASTEC
GASTEC Detector Tube: SO2, Gas Detection Tube, Sulfur Dioxide ( SO2 ), 32°F Min Op Temp [NEW], 10 PK (MPN 5D). Key specifications — Gas Detected: Sulfur Dioxide; Measurement Range: 0.2 to 100 ppm.
GASTEC Detector Tube: C2H4O, Gas Detection Tube, Acetaldehyde ( C2H4O ), With Pump, 10 PK (MPN 92M). Key specifications — Gas Detected: Acetaldehyde; Measurement Range: 2.5 to 100 ppm.
GASTEC
GASTEC Detector Tube: C2H4O, Gas Detection Tube, Acetaldehyde ( C2H4O ), With Pump, 10 PK (MPN 92M). Key specifications — Gas Detected: Acetaldehyde; Measurement Range: 2.5 to 100 ppm.
GASTEC Detector Tube: HCN, Gas Detection Tube, Hydrogen Cyanide ( HCN ), 1 to 200 ppm, 10 PK (MPN 12D). Key specifications — Gas Detected: Hydrogen Cyanide; Measurement Range: 1 to 200 ppm.
GASTEC
GASTEC Detector Tube: HCN, Gas Detection Tube, Hydrogen Cyanide ( HCN ), 1 to 200 ppm, 10 PK (MPN 12D). Key specifications — Gas Detected: Hydrogen Cyanide; Measurement Range: 1 to 200 ppm.
GASTEC Detector Tube: C2H4O, Gas Detection Tube, Acetaldehyde ( C2H4O ), With Pump, 10 PK (MPN 92). Key specifications — Gas Detected: Acetaldehyde; Measurement Range: 5 to 750 ppm.
GASTEC
GASTEC Detector Tube: C2H4O, Gas Detection Tube, Acetaldehyde ( C2H4O ), With Pump, 10 PK (MPN 92). Key specifications — Gas Detected: Acetaldehyde; Measurement Range: 5 to 750 ppm.
GASTEC Detector Tube: C2H6S, Gas Detection Tube, Ethyl Mercaptan ( C2H6S ), With Pump, 10 PK (MPN 72). Key specifications — Gas Detected: Ethyl Mercaptan; Measurement Range: 0.5 to 120 ppm.
GASTEC
GASTEC Detector Tube: C2H6S, Gas Detection Tube, Ethyl Mercaptan ( C2H6S ), With Pump, 10 PK (MPN 72). Key specifications — Gas Detected: Ethyl Mercaptan; Measurement Range: 0.5 to 120 ppm.
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), With Pump, 5 to 100 ppm, 5 PK (MPN 1LKC). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 5 to 100 ppm.
GASTEC
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), With Pump, 5 to 100 ppm, 5 PK (MPN 1LKC). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 5 to 100 ppm.