We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

GASTEC 159 Gas Detection Tube for Tetrahydrofuran (C4H8O), 10 Pack - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC 159 Gas Detection Tube for Tetrahydrofuran (C4H8O), 10 Pack

The GASTEC Detector Tube (MPN 159) is a gas detection tube for tetrahydrofuran (C4H8O), designed for use in GASTEC GV-100 and GV-110 pumps. It measures tetrahydrofuran concentrations from 25 to 800 ppm and is…

SKU 3G-OTH-553203

Brand
GASTEC
Item
159 Gas Detection Tube for Tetrahydrofuran
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

GASTEC
Manufacturer Part Number
159
Type
C4H8O, Gas Detection Tube, Tetrahydrofuran ( C4H8O ), 10 PK
Gas Detected
Tetrahydrofuran
Measurement Range
25 to 800 ppm

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube (MPN 159) is a gas detection tube for tetrahydrofuran (C4H8O), designed for use in GASTEC GV-100 and GV-110 pumps. It measures tetrahydrofuran concentrations from 25 to 800 ppm and is supplied in a pack of 10.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the GASTEC Detector Tube 159 used for?

The GASTEC Detector Tube 159 is used to measure tetrahydrofuran (C4H8O) concentrations in air, typically in industrial hygiene or leak detection. It works with GASTEC GV-100 and GV-110 pumps to provide spot-check readings from 25 to 800 ppm.

What are the specifications of the GASTEC Detector Tube 159?

The GASTEC Detector Tube 159 detects tetrahydrofuran (C4H8O) over a measurement range of 25 to 800 ppm. It is supplied in a pack of 10 tubes and is designed for use with GASTEC GV-100 and GV-110 pumps. The manufacturer part number is 159.

Where to buy GASTEC Detector Tube 159 worldwide?

3G Electric supplies the GASTEC Detector Tube 159 to customers worldwide. We handle full logistics, customs clearance, and delivery for international orders. Contact us to source this tetrahydrofuran detection tube for your GASTEC GV-100 or GV-110 pump.

How to use the GASTEC Detector Tube 159 with a GV-100 pump?

Break both tips of the GASTEC Detector Tube 159, insert it into the GASTEC GV-100 pump inlet, and pull the handle fully to draw a sample. Follow the pump stroke count and tube calibration chart to read the tetrahydrofuran concentration in ppm. Always refer to the tube instructions for correct procedure.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
Gas detection tube for carbon monoxide (CO) used with GASTEC GV-100 and GV-110 pumps. Each pack contains 10 calibrated tubes with a measurement range of 0.05 to 4%. Suitable for detecting CO in industrial environments such as combustion systems, HVAC, and process control
GASTEC
Gas detection tube for carbon monoxide (CO) used with GASTEC GV-100 and GV-110 pumps. Each pack contains 10 calibrated tubes with a measurement range of 0.05 to 4%. Suitable for detecting CO in industrial environments such as combustion systems, HVAC, and process control
GASTEC gas detection tube for chlorine (Cl2), designed for use with GV-100 and GV-110 pumps. Measures chlorine concentrations from 0.08 to 100 ppm. Maximum operating temperature 104°F. Pack of 10 tubes
GASTEC
GASTEC gas detection tube for chlorine (Cl2), designed for use with GV-100 and GV-110 pumps. Measures chlorine concentrations from 0.08 to 100 ppm. Maximum operating temperature 104°F. Pack of 10 tubes
GASTEC 4HM gas detection tube for hydrogen sulphide (H2S) with a measurement range of 25 to 1,600 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps. Supplied in a 10-pack. Used for detecting H2S in industrial environments such as oil and gas, wastewater, and chemical plants
GASTEC
GASTEC 4HM gas detection tube for hydrogen sulphide (H2S) with a measurement range of 25 to 1,600 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps. Supplied in a 10-pack. Used for detecting H2S in industrial environments such as oil and gas, wastewater, and chemical plants
Gas detection tube for methyl bromide (CH3Br) used with GASTEC GV-100 and GV-110 pumps. Measures concentrations from 2.5 to 200 ppm. Supplied in a pack of 5 tubes for field detection of fumigant gases
GASTEC
Gas detection tube for methyl bromide (CH3Br) used with GASTEC GV-100 and GV-110 pumps. Measures concentrations from 2.5 to 200 ppm. Supplied in a pack of 5 tubes for field detection of fumigant gases
GASTEC 5LB gas detection tube for sulphur dioxide (SO2). Designed for use with GASTEC GV-100 and GV-110 pumps. Measures SO2 concentrations from 0.05 to 10 ppm. Pack of 10 tubes for field sampling in industrial hygiene and environmental monitoring
GASTEC
GASTEC 5LB gas detection tube for sulphur dioxide (SO2). Designed for use with GASTEC GV-100 and GV-110 pumps. Measures SO2 concentrations from 0.05 to 10 ppm. Pack of 10 tubes for field sampling in industrial hygiene and environmental monitoring
GASTEC 4D is a gas detection tube for measuring hydrogen sulphide (H2S) concentrations in air. It has a measurement range of 0.2 to 200 ppm and is supplied in packs of 10. Designed for use with GASTEC GV-100 and GV-110 pumps, it is suitable for on-site detection in industrial environments such as refineries, wastewater treatment plants, and chemical processing facilities
GASTEC
GASTEC 4D is a gas detection tube for measuring hydrogen sulphide (H2S) concentrations in air. It has a measurement range of 0.2 to 200 ppm and is supplied in packs of 10. Designed for use with GASTEC GV-100 and GV-110 pumps, it is suitable for on-site detection in industrial environments such as refineries, wastewater treatment plants, and chemical processing facilities
Gas detection tube for formaldehyde (CH2O) used with GASTEC GV-100 and GV-110 pumps. Measures concentrations from 0.02 to 1.44 ppm with a required sample volume of 6,000 mL. Pack of 10 tubes for industrial hygiene and workplace air monitoring
GASTEC
Gas detection tube for formaldehyde (CH2O) used with GASTEC GV-100 and GV-110 pumps. Measures concentrations from 0.02 to 1.44 ppm with a required sample volume of 6,000 mL. Pack of 10 tubes for industrial hygiene and workplace air monitoring
Gas detection tube for hydrogen sulphide (H2S) with a measurement range of 1 to 40 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps. Pack of 10 tubes for spot-checking H2S concentrations in industrial environments such as refineries, wastewater plants, and confined spaces
GASTEC
Gas detection tube for hydrogen sulphide (H2S) with a measurement range of 1 to 40 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps. Pack of 10 tubes for spot-checking H2S concentrations in industrial environments such as refineries, wastewater plants, and confined spaces