We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

GASTEC Detector Tube: CH3OH, Gas Detection Tube, Methanol ( CH3OH), With Pump - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Detector Tube: CH3OH, Gas Detection Tube, Methanol ( CH3OH), With Pump

The GASTEC Detector Tube: CH3OH (MPN 111LL) is a gas detection tube for methanol (CH3OH) with a measurement range of 2 to 62 ppm, designed for use with GASTEC GV-100 and GV-110 pumps. Supplied in packs of 10, it…

SKU 3G-OTH-553231

Also listed as: 111 LL · 111-LL

Brand
GASTEC
Item
Detector Tube: CH3OH, Gas Detection Tube, Methanol
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

GASTEC
Manufacturer Part Number
111LL
Type
Gas Detection Tube, Methanol ( CH3OH ), With Pump, 2 to 62 ppm, 10 PK
Gas Detected
Methanol
Measurement Range
2 to 62 ppm

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube: CH3OH (MPN 111LL) is a gas detection tube for methanol (CH3OH) with a measurement range of 2 to 62 ppm, designed for use with GASTEC GV-100 and GV-110 pumps. Supplied in packs of 10, it enables on-site methanol concentration measurement across 14 industrial departments — and we supply far more than is listed. Our specialist depth in combustion, pumps and controls (authorised distributor for brands like FBR, Interpump, Riello, Beckett, Schneider, ABB, Siemens, SKF, Festo, Fluke) ensures you get the right answer, not just a catalog.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the GASTEC 111LL detector tube used for?

The GASTEC 111LL detector tube measures methanol (CH3OH) concentrations from 2 to 62 ppm in workplace air. It is used for industrial hygiene, leak detection, and process monitoring across sectors like chemical processing, pharmaceuticals, and manufacturing. 3G Electric supplies this tube for use with GASTEC GV-100 and GV-110 pumps.

What are the specifications of the GASTEC 111LL methanol tube?

The GASTEC 111LL is a gas detection tube for methanol (CH3OH) with a measurement range of 2 to 62 ppm. It is designed for use with GASTEC GV-100 and GV-110 pumps and is supplied in packs of 10. The manufacturer part number is 111LL.

Where to buy GASTEC 111LL detector tubes worldwide?

3G Electric supplies GASTEC 111LL methanol detector tubes worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this gas detection tube for methanol measurement.

How to use the GASTEC 111LL methanol detector tube?

Break both tips of the GASTEC 111LL tube, insert it into a GASTEC GV-100 or GV-110 pump, and pull the handle to draw a sample. Read the concentration directly from the stain length on the tube scale. Follow standard gas detection tube procedures for accurate methanol measurement from 2 to 62 ppm.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC Detector Tube: GASTEC GV-100, SO2, Gas Detection Tube, Sulphur Dioxide ( SO2), 10 PK (MPN 5LB)
GASTEC
GASTEC Detector Tube: GASTEC GV-100, SO2, Gas Detection Tube, Sulphur Dioxide ( SO2), 10 PK (MPN 5LB)
GASTEC Detector Tube: PH3, Gas Detection Tube, Phosphine ( PH3), With Pump, 200 to 5500 ppm, 10 PK (MPN 7H)
GASTEC
GASTEC Detector Tube: PH3, Gas Detection Tube, Phosphine ( PH3), With Pump, 200 to 5500 ppm, 10 PK (MPN 7H)
GASTEC Detector Tube: NH3, Gas Detection Tube, Ammonia ( NH3), 104°F Max Op Temp [NEW], 10 PK (MPN 3D)
GASTEC
GASTEC Detector Tube: NH3, Gas Detection Tube, Ammonia ( NH3), 104°F Max Op Temp [NEW], 10 PK (MPN 3D)
GASTEC Detector Tube: H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S), 0.2 to 200 ppm, 10 PK (MPN 4D)
GASTEC
GASTEC Detector Tube: H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S), 0.2 to 200 ppm, 10 PK (MPN 4D)
GASTEC Detector Tube: GASTEC GV-100, H2O2, Gas Detection Tube, Hydrogen Peroxide ( H2O2), 10 PK (MPN 32)
GASTEC
GASTEC Detector Tube: GASTEC GV-100, H2O2, Gas Detection Tube, Hydrogen Peroxide ( H2O2), 10 PK (MPN 32)
GASTEC Detector Tube: GASTEC GV-100, H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S), 10 PK (MPN 4H)
GASTEC
GASTEC Detector Tube: GASTEC GV-100, H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S), 10 PK (MPN 4H)
GASTEC Detector Tube: GASTEC GV-100, C6H6, Gas Detection Tube, Benzene ( C6H6), With Pump, 5 PK (MPN 121SL)
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C6H6, Gas Detection Tube, Benzene ( C6H6), With Pump, 5 PK (MPN 121SL)
GASTEC Detector Tube: GASTEC GV-100, C3H8O, Gas Detection Tube, Isopropyl Alcohol ( C3H8O), 10 PK (MPN 113L)
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C3H8O, Gas Detection Tube, Isopropyl Alcohol ( C3H8O), 10 PK (MPN 113L)