The GAST R6P350A is a 5 hp, 1-stage regenerative blower with a three-phase motor rated at 208 to 230/460V AC and 12.2-11.2/5.6 A. It delivers a maximum operating pressure of 70 in wc, a maximum vacuum of 70 in Hg…

SKU 3G-OTH-189417

Brand
GAST
Item
Regenerative Blower: 5 hp, 70 in wc Max Op Pressure, 70 in Hg Max Vacuum
Category
1-Stage Regenerative Blowers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

GAST
Manufacturer Part Number
R6P350A
Type
70 in wc Max Op Pressure
Hg Max Vacuum
70 in
Max Flow Rate
275 cfm
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GAST Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GAST R6P350A is a 5 hp, 1-stage regenerative blower with a three-phase motor rated at 208 to 230/460V AC and 12.2-11.2/5.6 A. It delivers a maximum operating pressure of 70 in wc, a maximum vacuum of 70 in Hg, and a maximum flow rate of 275 cfm. The unit features female NPT connections and is designed for industrial air movement applications.

Used in

Common applications for GAST
Laboratory air supply — GAST Oil-Free Rocking Piston Air Compressor (1760408) for clean, oil-free compressed air
Material handling — GAST Regenerative Blower (R3105-12) for conveying or aeration in packaging lines
Medical vacuum — GAST Rotary Vane Vacuum Pump (AT05-101-G215DX) for suction in clinical or laboratory settings
Pneumatic control — GAST Reciprocating Piston Compressor (4LCB-55S-M450GX) for powering actuators in manufacturing
Environmental monitoring — GAST Diaphragm Compressor/Vacuum Pump (DOA-P707-AA) for air sampling or gas analysis
Mobile equipment — GAST DC Piston Compressor (3HBB-19-M322A) for on-vehicle pneumatic systems

GAST Products

3G Electric supplies GAST 1-stage regenerative blowers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
GAST Regenerative Blower: 6 hp, 110 in wc Max Op Pressure, 90 in wc Max Vacuum, 16-15/7.5 A (MPN R6P355A). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R6P355A; attr49822: 16-15/7.5 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 208 to 230/460V AC.
GAST
GAST Regenerative Blower: 6 hp, 110 in wc Max Op Pressure, 90 in wc Max Vacuum, 16-15/7.5 A (MPN R6P355A). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R6P355A; attr49822: 16-15/7.5 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 208 to 230/460V AC.
GAST Regenerative Blower: 10 hp, 125 in wc Max Op Pressure, 110 in wc Max Vacuum, 25.8-24.6/12.3 A (MPN R7100A-3). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R7100A-3; attr49822: 25.8-24.6/12.3 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 208 to 230/460V AC.
GAST
GAST Regenerative Blower: 10 hp, 125 in wc Max Op Pressure, 110 in wc Max Vacuum, 25.8-24.6/12.3 A (MPN R7100A-3). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R7100A-3; attr49822: 25.8-24.6/12.3 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 208 to 230/460V AC.
GAST Regenerative Blower: 1 hp, 52 in wc Max Op Pressure, 48 in wc Max Vacuum, 92 cfm Max Flow Rate (MPN R4310A-2). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R4310A-2; attr49822: 3.4-3.2/1.6 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 208 to 230/460V AC.
GAST
GAST Regenerative Blower: 1 hp, 52 in wc Max Op Pressure, 48 in wc Max Vacuum, 92 cfm Max Flow Rate (MPN R4310A-2). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R4310A-2; attr49822: 3.4-3.2/1.6 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 208 to 230/460V AC.
GAST Regenerative Blower: 0.5 hp, 55 in wc Max Op Pressure, 50 in wc Max Vacuum, 6.0/3.2-3.0 A (MPN R3105-12). Key specifications — attr49842: Single; attr49816: GAST; attr49813: R3105-12; attr49822: 6.0/3.2-3.0 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 115/208 to 230V AC.
GAST
GAST Regenerative Blower: 0.5 hp, 55 in wc Max Op Pressure, 50 in wc Max Vacuum, 6.0/3.2-3.0 A (MPN R3105-12). Key specifications — attr49842: Single; attr49816: GAST; attr49813: R3105-12; attr49822: 6.0/3.2-3.0 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 115/208 to 230V AC.
GAST Regenerative Blower: 2.5 hp, 65 in wc Max Op Pressure, 60 in wc Max Vacuum, 6.6-6.2/3.1 A (MPN R5325A-2). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R5325A-2; attr49822: 6.6-6.2/3.1 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 208 to 230/460V AC.
GAST
GAST Regenerative Blower: 2.5 hp, 65 in wc Max Op Pressure, 60 in wc Max Vacuum, 6.6-6.2/3.1 A (MPN R5325A-2). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R5325A-2; attr49822: 6.6-6.2/3.1 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 208 to 230/460V AC.
GAST Regenerative Blower: 5 hp, 105 in wc Max Op Pressure, 88 in wc Max Vacuum, 12.2-11.2/5.6 A (MPN R6350A-2). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R6350A-2; attr49822: 12.2-11.2/5.6 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 190 to 220/380 to 415V AC.
GAST
GAST Regenerative Blower: 5 hp, 105 in wc Max Op Pressure, 88 in wc Max Vacuum, 12.2-11.2/5.6 A (MPN R6350A-2). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R6350A-2; attr49822: 12.2-11.2/5.6 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 190 to 220/380 to 415V AC.

More from GAST

View all GAST parts
GAST Regenerative Blower: 1.5 hp, 65 in wc Max Op Pressure, 60 in wc Max Vacuum, 17.5/10-9 A (MPN R4P115). Key specifications — attr49842: Single; attr49816: GAST; attr49813: R4P115; attr49822: 17.5/10-9 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 115/208 to 230V AC.
GAST
GAST Regenerative Blower: 1.5 hp, 65 in wc Max Op Pressure, 60 in wc Max Vacuum, 17.5/10-9 A (MPN R4P115). Key specifications — attr49842: Single; attr49816: GAST; attr49813: R4P115; attr49822: 17.5/10-9 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 115/208 to 230V AC.
GAST Regenerative Blower: 0.12 hp, 28 in wc Max Op Pressure, 26.5 in wc Max Vacuum (MPN R1102K-01). Key specifications — attr49842: Single; attr49816: GAST; attr49813: R1102K-01; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 110/220 to 240V AC; attr49849: Female.
GAST
GAST Regenerative Blower: 0.12 hp, 28 in wc Max Op Pressure, 26.5 in wc Max Vacuum (MPN R1102K-01). Key specifications — attr49842: Single; attr49816: GAST; attr49813: R1102K-01; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 110/220 to 240V AC; attr49849: Female.
GAST Regenerative Blower: 1 hp, 52 in wc Max Op Pressure, 48 in wc Max Vacuum, 92 cfm Max Flow Rate (MPN R4110-2). Key specifications — attr49842: Single; attr49816: GAST; attr49813: R4110-2; attr49822: 9.8/5.2-4.9 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 115/208 to 230V AC.
GAST
GAST Regenerative Blower: 1 hp, 52 in wc Max Op Pressure, 48 in wc Max Vacuum, 92 cfm Max Flow Rate (MPN R4110-2). Key specifications — attr49842: Single; attr49816: GAST; attr49813: R4110-2; attr49822: 9.8/5.2-4.9 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 115/208 to 230V AC.
GAST Regenerative Blower: 3.5 hp, 80 in wc Max Op Pressure, 80 in wc Max Vacuum, 9.2-8.4/4.2 A (MPN R6335A-2). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R6335A-2; attr49822: 9.2-8.4/4.2 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 190 to 220/380 to 415V AC.
GAST
GAST Regenerative Blower: 3.5 hp, 80 in wc Max Op Pressure, 80 in wc Max Vacuum, 9.2-8.4/4.2 A (MPN R6335A-2). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R6335A-2; attr49822: 9.2-8.4/4.2 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 190 to 220/380 to 415V AC.
GAST Regenerative Blower: 2.5 hp, 65 in wc Max Op Pressure, 60 in wc Max Vacuum, 22/12.5-11 A (MPN R5125-2). Key specifications — attr49842: Single; attr49816: GAST; attr49813: R5125-2; attr49822: 22/12.5-11 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 115/208 to 230V AC.
GAST
GAST Regenerative Blower: 2.5 hp, 65 in wc Max Op Pressure, 60 in wc Max Vacuum, 22/12.5-11 A (MPN R5125-2). Key specifications — attr49842: Single; attr49816: GAST; attr49813: R5125-2; attr49822: 22/12.5-11 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 115/208 to 230V AC.
GAST Regenerative Blower: 2 hp, 65 in wc Max Op Pressure, 60 in wc Max Vacuum, 160 cfm Max Flow Rate (MPN R5325R-50). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R5325R-50; attr49830: NPT; attr49833: NPT; attr49845: 208-230/460V AC.
GAST
GAST Regenerative Blower: 2 hp, 65 in wc Max Op Pressure, 60 in wc Max Vacuum, 160 cfm Max Flow Rate (MPN R5325R-50). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R5325R-50; attr49830: NPT; attr49833: NPT; attr49845: 208-230/460V AC.
GAST Regenerative Blower: 0.33 hp, 39 in wc Max Op Pressure, 35 in wc Max Vacuum, 4.3/2.4-2.2 A (MPN R2103NX). Key specifications — attr49842: Single; attr49816: GAST; attr49813: R2103NX; attr49822: 4.3/2.4-2.2 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 115/208-230V AC.
GAST
GAST Regenerative Blower: 0.33 hp, 39 in wc Max Op Pressure, 35 in wc Max Vacuum, 4.3/2.4-2.2 A (MPN R2103NX). Key specifications — attr49842: Single; attr49816: GAST; attr49813: R2103NX; attr49822: 4.3/2.4-2.2 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 115/208-230V AC.
GAST Regenerative Blower: 1.5 hp, 63 in wc Max Op Pressure, 59 in wc Max Vacuum, 4.0-3.8/1.9 A (MPN R4P315A). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R4P315A; attr49822: 4.0-3.8/1.9 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 208 to 230/460V AC.
GAST
GAST Regenerative Blower: 1.5 hp, 63 in wc Max Op Pressure, 59 in wc Max Vacuum, 4.0-3.8/1.9 A (MPN R4P315A). Key specifications — attr49842: Three; attr49816: GAST; attr49813: R4P315A; attr49822: 4.0-3.8/1.9 A; attr49827: Female; attr49830: NPT; attr49833: NPT; attr49845: 208 to 230/460V AC.