We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

GASCO Calibration Gas: Methane 1.45% in Nitrogen, Disposable Cylinder - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO Calibration Gas: Methane 1.45% in Nitrogen, Disposable Cylinder

The GASCO Calibration Gas: Nitrogen is a disposable calibration gas for portable gas detectors, featuring a methane mixture (29% LEL) at 1.45% with +/-5% accuracy. Designed for use with all OEM gas detectors, it uses…

SKU 3G-OTH-549338

Brand
GASCO
Item
Calibration Gas: Methane 1.45% in Nitrogen, Disposable Cylinder
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

GASCO
Manufacturer Part Number
X06NI81CA340000
Type
Disposable, +/-5% Accuracy, CH4/CO/CO2/H2S/O2, Calibration Gas
Gas Mixture
Methane (29% LEL) 1.45%
Reusability
Disposable
For Use With
All OEM Gas Detectors
Background Gas
Nitrogen

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Nitrogen is a disposable calibration gas for portable gas detectors, featuring a methane mixture (29% LEL) at 1.45% with +/-5% accuracy. Designed for use with all OEM gas detectors, it uses nitrogen as the background gas and is supplied under MPN X06NI81CA340000.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is GASCO calibration gas used for?

GASCO calibration gas is used to verify and adjust the accuracy of portable gas detectors that sense methane, carbon monoxide, carbon dioxide, hydrogen sulfide, and oxygen. It is suitable for all OEM gas detectors and is supplied as a disposable cylinder with nitrogen background gas.

What are the specifications of GASCO calibration gas X06NI81CA340000?

This GASCO calibration gas is a disposable mixture with +/-5% accuracy. It contains methane at 1.45% (29% LEL) in a nitrogen background. The manufacturer part number is X06NI81CA340000, and it is designed for use with all OEM gas detectors.

Where to buy GASCO calibration gas worldwide?

3G Electric supplies GASCO calibration gas worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us to order the X06NI81CA340000 disposable calibration gas for your portable gas detectors.

How to use GASCO disposable calibration gas?

Attach the GASCO cylinder to your gas detector's regulator, open the valve, and expose the sensor to the flowing gas. Follow the detector manufacturer's calibration procedure. After use, close the valve and dispose of the cylinder responsibly. Always verify the gas mixture and expiration date before use.

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from GASCO

View all GASCO parts
Disposable calibration gas mixture containing 0.3% Isobutane (16% LEL) in air, with ±5% accuracy. Fitted with a CGA 600 connection for use with portable gas detectors. Used to verify and calibrate sensor response in industrial safety monitoring applications
GASCO
Disposable calibration gas mixture containing 0.3% Isobutane (16% LEL) in air, with ±5% accuracy. Fitted with a CGA 600 connection for use with portable gas detectors. Used to verify and calibrate sensor response in industrial safety monitoring applications
Disposable calibration gas mixture containing methane at 20% LEL (9,960 ppm) with +/-5% accuracy, balanced in air. Used to verify and adjust the response of portable gas detectors in industrial environments. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas mixture containing methane at 20% LEL (9,960 ppm) with +/-5% accuracy, balanced in air. Used to verify and adjust the response of portable gas detectors in industrial environments. Compatible with all OEM gas detectors
Disposable calibration gas mixture containing 100 ppm carbon monoxide with a background of air. Provides ±5% accuracy for verifying and calibrating portable gas detectors. Compatible with all OEM gas detectors in industrial safety applications
GASCO
Disposable calibration gas mixture containing 100 ppm carbon monoxide with a background of air. Provides ±5% accuracy for verifying and calibrating portable gas detectors. Compatible with all OEM gas detectors in industrial safety applications
Calibration gas cylinder containing 490 ppm carbon monoxide in a background of air. Provides +/-2% accuracy for verifying and adjusting the response of portable gas detectors. Cylinder capacity is 105 L. Compatible with all OEM gas detectors
GASCO
Calibration gas cylinder containing 490 ppm carbon monoxide in a background of air. Provides +/-2% accuracy for verifying and adjusting the response of portable gas detectors. Cylinder capacity is 105 L. Compatible with all OEM gas detectors
Disposable calibration gas cylinder containing butane at 22% LEL (0.414%) in nitrogen background. Accuracy ±5%. For use with all OEM gas detectors to verify and adjust combustible gas sensor response in industrial safety applications
GASCO
Disposable calibration gas cylinder containing butane at 22% LEL (0.414%) in nitrogen background. Accuracy ±5%. For use with all OEM gas detectors to verify and adjust combustible gas sensor response in industrial safety applications
Disposable calibration gas cylinder containing propane at 1,250 ppm in air, with +/-5% accuracy. Used for verifying and adjusting the response of portable gas detectors in environments where combustible gases may be present. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas cylinder containing propane at 1,250 ppm in air, with +/-5% accuracy. Used for verifying and adjusting the response of portable gas detectors in environments where combustible gases may be present. Compatible with all OEM gas detectors
Disposable calibration gas mixture containing 25 ppm hydrogen sulfide balanced in nitrogen, with +/-5% accuracy. Designed for use with all OEM portable gas detectors to verify and adjust sensor response. Suitable for industrial safety applications such as confined-space entry and area monitoring
GASCO
Disposable calibration gas mixture containing 25 ppm hydrogen sulfide balanced in nitrogen, with +/-5% accuracy. Designed for use with all OEM portable gas detectors to verify and adjust sensor response. Suitable for industrial safety applications such as confined-space entry and area monitoring
Disposable calibration gas cylinder containing 20 ppm methanol in air, with ±5% accuracy. Fitted with a CGA 165 connection for use with portable gas detectors requiring methanol calibration. Suitable for verifying detector response in industrial safety environments
GASCO
Disposable calibration gas cylinder containing 20 ppm methanol in air, with ±5% accuracy. Fitted with a CGA 165 connection for use with portable gas detectors requiring methanol calibration. Suitable for verifying detector response in industrial safety environments